7 resultados para Self-evaluation

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the association between noise levels present in preschool institutions and vocal disorders among educators. METHODS: Cross-sectional study conducted in 2009 with 28 teachers from three preschool institutions located in the city of Sao Paulo (Southeastern Brazil). Sound pressure levels were measured according to Brazilian Technical Standards Association, with the use of a sound level meter. The averages were classified according to the levels of comfort, discomfort, and auditory damage proposed by the Pan American Health Organization. The educators underwent voice evaluation: self-assessment with visual analogue scale, auditory perceptual evaluation using the GRBAS scale, and acoustic analysis utilizing the Praat program. To analyze the association between noise and voice evaluation, descriptive statistics and the chi-square test were employed, with significance of 10% due to sample size. RESULTS: The teachers' age ranged between 21 and 56 years. The noise average was 72.7 dB, considered as damage 2. The professionals' vocal self-assessment ranked an average of 5.1 on the scale, being considered as moderate alteration. In the auditory-perceptual assessment, 74% presented vocal alteration, especially hoarseness; of these, 52% were considered mild alterations. In the acoustic assessment the majority presented fundamental frequency below the expected level. Averages for jitter, shimmer and harmonic-noise ratio showed alterations. An association between the presence of noise between the harmonics and vocal disorders was observed. CONCLUSIONS: There is an association between presence of noise between the harmonics and vocal alteration, with high noise levels. Although most teachers presented mild voice alteration, the self-evaluation showed moderate alteration, probably due to the difficulty in projection.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O bem-estar subjetivo surgiu como um interessante tema da Psicologia Positiva e tem recebido cada vez mais atenção de pesquisadores da área. Este estudo teve como objetivo principal verificar a eficácia de três instrumentos de autoavaliação do bem-estar subjetivo, a partir de uma população de estudantes universitários da cidade de Ribeirão Preto. Foi realizada a análise estatística descritiva e a análise de componentes principais para os resultados apresentados no Questionário de Felicidade Oxford e na Escala de Felicidade Subjetiva. O Item de Felicidade Global foi analisado apenas por intermédio da estatística descritiva, pois apresentava uma única questão. Partindo do fato de que pesquisas realizadas indicam uma diferença pouco significativa entre autoavaliações realizadas por homens e por mulheres, este estudo traz resultados que confirmam essa constatação quanto às medianas apresentadas em todos os instrumentos, porém aponta diferenças significativas em relação à estrutura dos instrumentos de homens e mulheres para o Questionário de Felicidade Oxford.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite their importance in the evaluation of petroleum and gas reservoirs, measurements of self-potential data under borehole conditions (well-logging) have found only minor applications in aquifer and waste-site characterization. This can be attributed to lower signals from the diffusion fronts in near-surface environments because measurements are made long after the drilling of the well, when concentration fronts are already disappearing. Proportionally higher signals arise from streaming potentials that prevent using simple interpretation models that assume signals from diffusion only. Our laboratory experiments found that dual-source self-potential signals can be described by a simple linear model, and that contributions (from diffusion and streaming potentials) can be isolated by slightly perturbing the borehole conditions. Perturbations are applied either by changing the concentration of the borehole-filling solution or its column height. Parameters useful for formation evaluation can be estimated from data measured during perturbations, namely, pore water resistivity, pressure drop across the borehole wall, and electrokinetic coupling parameter. These are important parameters to assess, respectively, water quality, aquifer lateral continuity, and interfacial properties of permeable formations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this research was to test the hypothesis that treatment with intra-oral appliances with different occlusal designs was beneficial in the management of pain of masticatory muscles compared with a control group. A total of 51 patients were analysed according to the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) to obtain the diagnosis of masticatory myofascial pain (MMP). The sample was then randomly divided into three groups: group I (n = 21) wore a full coverage acrylic stabilisation occlusal splint; group II (n = 16) wore an anterior device nociceptive trigeminal inhibitory (NTI) system; and group III (n = 14) only received counselling for behavioural changes and self-care (the control group). The first two groups also received counselling. Follow-ups were performed after 2 and 6 weeks and 3 months. In these sessions, patients were evaluated by means of a visual analogue scale (VAS) and pressure pain threshold (PPT) of the masticatory muscles. Possible adverse effects were also recorded, such as discomfort while using the appliance and occlusal changes. The results were analysed with KruskalWallis, anova, Tukeys and Friedman tests, with a significance level of 5%. Group I showed improvement in the reported pain at the first follow-up (2 weeks), whereas for groups II and III, this progress was detected only after 6 weeks and 3 months, respectively. The PPT values did not change significantly. It was concluded that behavioural changes are effective in the management of pain in MMP patients. However, the simultaneous use of occlusal devices appears to produce an earlier improvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Arthritis may affect the larynx and produce symptoms such as hoarseness and vocal fatigue. Objective: This paper aimed to evaluate the laryngeal manifestations of rheumatoid arthritis. Methods: This is prospective study assessed 27 patients with rheumatoid arthritis with the aid of videolaryngostroboscopy, auditory-perceptual analysis of the speech using the GIRBAS scale, acoustic analysis and the Voice Handicap Index questionnaire. Results: Nineteen patients had laryngeal complaints, the main ones being intermittent dysphonia and sensation of a foreign body in the throat. The most frequent laryngoscopical finding was overlapping arytenoids. Three patients had low pitch, nine patients had mild dysphonia and roughness. Median acoustic measures were: F0, 198.39 Hz; Jitter, 0.815; Shimmer, 4.915; and NHR, 0.144. Regarding the Voice Handicap Index, the median score was zero in all domains. There was a statistically significant correlation between voice complaints and the domains of this index. Functional classes were significantly correlated to: overlapping arytenoids (p = 0.001), PPQ (p = 0.0257), Shimmer (p = 0.0295), APQ (p = 0.0195), and the VHI physical (p = 0.0227) and total domains (p = 0.0425). Conclusion: Laryngeal complaints were reported by 70.4% of the patients and laryngoscopical alterations were observed in 48% of the subjects. Voice acoustic evaluation and self-perception were altered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate in vivo the failure rate of metallic brackets bonded with two orthodontic composites. Nineteen patients with ages ranging from 10.5 to 38.7 years needing corrective orthodontic treatment were selected for study. The enamel surfaces from second premolars to second premolars were treated with Transbond Plus-Self Etching Primer (3M Unitek). Next, 380 orthodontic brackets were bonded on maxillary and mandibular teeth, as follows: 190 with Transbond XT composite (3M Unitek) (control) and 190 with Transbond Plus Color Change (3M Unitek) (experimental) in contralateral quadrants. The bonded brackets were light cured for 40 s, and initial alignment archwires were inserted. Bond failure rates were recorded over a six-month period. At the end of the evaluation, six bond failures occurred, three for each composite. Kaplan-Meyer method and log-rank test (Mantel-Cox) was used for statistical analysis, and no statistically significant difference was found between the materials (p=0.999). Both Transbond XT and Transbond Plus Color Change composites had low debonding rates over the study period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this study was to evaluate in vivo the bonding of metallic orthodontic brackets with different adhesive systems. MATERIAL AND METHODS: Twenty patients (10.5-15.1 years old) who had sought corrective orthodontic treatment at a University Orthodontic Clinic were evaluated. Brackets were bonded from the right second premolar to the left second premolar in the upper and lower arches using: Orthodontic Concise, conventional Transbond XT, Transbond XT without primer, and Transbond XT associated with Transbond Plus Self-etching Primer (TPSEP). The 4 adhesive systems were used in all patients using a split-mouth design; each adhesive system was used in one quadrant of each dental arch, so that each group of 5 patients received the same bonding sequence. Initial archwires were inserted 1 week after bracket bonding. The number of bracket failures for each adhesive system was quantified over a 6-month period. RESULTS: The number of debonded brackets was: 8- Orthodontic Concise, 2- conventional Transbond XT, 9- Transbond XT without primer, and 1- Transbond XT + TPSEP. By using the Kaplan-Meier methods, statistically significant differences were found between the materials (p=0.0198), and the Logrank test identified these differences. Conventional Transbond XT and Transbond XT + TPSEP adhesive systems were statistically superior to Orthodontic Concise and Transbond XT without primer (p<0.05). There was no statistically significant difference between the dental arches (upper and lower), between the dental arch sides (right and left), and among the quadrants. CONCLUSIONS: The largest number of bracket failures occurred with Orthodontic Concise and Transbond XT without primer systems and few bracket failures occurred with conventional Transbond XT and Transbond XT+TPSEP. More bracket failures were observed in the posterior region compared with the anterior region.