8 resultados para STOCKINGS, COMPRESSION
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Aim. The aim of this study was to evaluate whether an association of elastic stockings and walking for a short period in the late afternoon reduces leg edema. Methods. Volume changes of the legs of sixteen patients (32 limbs), who walked on a treadmill for 30 minutes using elastic compression stockings, were analyzed in a quantitative, cross-over randomized (in order of arrival at the clinic) study. They were submitted to volumetry using the water displacement technique and subsequently required to put on 20/30 made-to-measure compression stockings (Sigvaris). The patients walked on a treadmill for 30 minutes and after removing the stockings volumetry of the legs was again performed. Legs were assessed using the CEAP classification and divided into groups. Analysis of variance was used for statistical analysis with an alpha error of 5% being considered acceptable. Results. When participants walked wearing compression stockings, there was a reduction in leg volume. When the CEAP classification was evaluated, it was noted that there was a statistically significant difference for the CEAP C0, C1 and C2 categories of legs using stockings compared to those that did not use. Conclusion. Compression stockings have a synergistic effect with walking in the late afternoon thus reducing edema of the lower limbs. [Int Angiol 2012;31:490-3]
Resumo:
The centrifuge technique was used to investigate the influence of particle size, applied compression, and substrate material (stainless steel, glass, Teflon, and poly(vinyl chloride)) on particle-surface adhesion force. For this purpose, phosphatic rock (rho(p) = 3090 kg/m(3)) and manioc starch particles (rho(p) = 1480 kg/m(3)) were used as test particles. A microcentrifuge that reached a maximum rotation speed of 14 000 rpm and which contained specially designed centrifuge tubes was used in the adhesion force measurements. The curves showed that the adhesion force profile followed a normal log distribution. The adhesion force increased linearly with particle size and with the increase of each increment of compression force. The manioc starch particles presented greater adhesion forces than the phosphatic rock particles for all particle sizes studied. The glass substrate showed a higher adherence than the other materials, probably due to its smoother topographic surface roughness in relation to the other substrata.
Resumo:
Background Chyle fistulas may occur after left neck dissections that include level IV, due to injury of the thoracic duct or of 1 of its major branches. Despite being unusual, this complication carries substantial postoperative morbidity and even mortality. So far, no effective intraoperative maneuver has been reported to detect this fistula at the end of a neck dissection. In this cohort study, we sought to describe a simple new maneuver, intraoperative abdominal compression, which can effectively help to identify an open major lymphatic duct on level IV at the end of a neck dissection. Patients and Methods From March 1989 to September 2010, 206 patients underwent neck dissections involving left level IV, and underwent intraoperative abdominal compression. There were 119 men and 87 women, with ages ranging from 18 to 81 years (median, 52 years). One hundred forty-four patients had squamous cell carcinomas, 54 had thyroid carcinomas, 5 had malignant melanomas, and 3 had salivary cancers. Distribution by type of left neck dissection was: selective including levels II, III, and IV (73 cases; 35.4%), selective including levels II, III, IV, and V (55 cases; 26.6%), selective including levels I, II, III, and IV (12 cases; 5.8%), modified radical (47 cases; 22.8%), and radical (19 cases; 9.2%). In all cases, at the end of the procedure, the endotracheal tube was temporarily disconnected from the ventilator. Keeping the dissected level IV area under clear visualization, an abdominal compression was performed. At this moment, any detected lymphatic leak was carefully clamped and tied with nonabsorbable sutures. After ventilating the patient, the intraoperative abdominal compression was repeated to reassure complete occlusion of the lymphatic vessel. Results In 13 cases (6.3%), a chyle leak was detected after performing the intraoperative abdominal compression. All leaks except for 2 were successfully controlled after 1 attempt. In these 2 patients, a patch of muscle and fat tissue was applied with fibrin glue on the top. In 1 of these patients, another chyle leak in a different location was detected only at the second intraoperative abdominal compression, and was also effectively closed. Postoperatively, there were 2 (1%) chyle fistulas, both among these 13 cases, and all were successfully managed with clinical measures only. No fistulas occurred among the remaining 193 patients in whom intraoperative abdominal compression did not demonstrate lymphatic leak. Conclusion To our knowledge, this is the first description of a specific maneuver to actively detect a lymphatic fistula at the end of a left neck dissection involving level IV. In this study, intraoperative abdominal compression was able to detect an open lymphatic vessel in 6.3% of the cases, as well as to assure its effective sealing in the remaining 93.7% of the patients. Moreover, no life-threatening high-volume fistula was noted in this study. (C) 2012 Wiley Periodicals, Inc. Head Neck, 2012
Resumo:
During orthodontic tooth movement (OTM), alveolar bone is resorbed by osteoclasts in compression sites (CS) and is deposited by osteoblasts in tension sites (TS). The aim of this study was to develop a standardized OTM protocol in mice and to investigate the expression of bone resorption and deposition markers in CS and TS. An orthodontic appliance was placed in C57BL6/J mice. To define the ideal orthodontic force, the molars of the mice were subjected to forces of 0.1 N, 0.25 N, 0.35 N and 0.5 N. The expression of mediators that are involved in bone remodeling at CS and TS was analyzed using a Real-Time PCR. The data revealed that a force of 0.35 N promoted optimal OTM and osteoclast recruitment without root resorption. The levels of TNF-alpha, RANKL, MMP13 and OPG were all altered in CS and TS. Whereas TNF-a and Cathepsin K exhibited elevated levels in CS. RUNX2 and OCN levels were higher in TS. Our results suggest that 0.35 N is the ideal force for OTM in mice and has no side effects. Moreover, the expression of bone remodeling markers differed between the compression and the tension areas, potentially explaining the distinct cellular migration and differentiation patterns in each of these sites. (C) 2012 Elsevier Ltd. All rights reserved.
Resumo:
Aims To evaluate the ability of multifocal transient pattern electroretinography (mfPERG) to detect neural loss and assess the relationship between mfPERG and visual-field (VF) loss in eyes with chiasmal compression. Methods 23 eyes from 23 patients with temporal VF defects and band atrophy of the optic nerve and 21 controls underwent standard automated perimetry and mfPERG using a stimulus pattern of 19 rectangles, each consisting of 12 squares. The response was determined for the central rectangle, for the nasal and temporal hemifields (eight rectangles each) and for each quadrant (three rectangles) in both patients and controls. Comparisons were made using variance analysis. Correlations between VF and mfPERG measurements were verified by linear regression analysis. Results Mean +/- SD mfPERG amplitudes from the temporal hemifield (0.50 +/- 0.17 and 0.62 +/- 0.32) and temporal quadrants (superior 0.42 +/- 0.21 and 0.52 +/- 0.35, inferior 0.51 +/- 0.23 and 0.74 +/- 0.40) were significantly lower in eyes with band atrophy than in controls (0.78 +/- 0.24, 0.89 +/- 0.28, 0.73 +/- 60.26, 0.96 +/- 0.36, 0.79 +/- 0.26 and 0.91 +/- 0.31, respectively). No significant difference was observed in nasal hemifield measurements. Significant correlations (0.36-0.73) were found between VF relative sensitivity and mfPERG amplitude in different VF sectors. Conclusions mfPERG amplitude measurements clearly differentiate eyes with temporal VF defect from controls. The good correlation between mfPERG amplitudes and the severity of VF defect suggests that mfPERG may be used as an indicator of ganglion cell dysfunction.
Resumo:
This paper emphasizes the influence of micro mechanisms of failure of a cellular material on its phenomenological response. Most of the applications of cellular materials comprise a compression loading. Thus, the study focuses on the influence of the anisotropy in the mechanical behavior of cellular material under cyclic compression loadings. For this study, a Digital Image Correlation (DIC) technique (named Correli) was applied, as well as SEM (Scanning Electron Microscopy) images were analyzed. The experimental results are discussed in detail for a closed-cell rigid poly (vinyl chloride) (PVC) foam, showing stress-strain curves in different directions and why the material can be assumed as transversely isotropic. Besides, the present paper shows elastic and plastic Poisson's ratios measured in different planes, explaining why the plastic Poisson's ratios approach to zero. Yield fronts created by the compression loadings in different directions and the influence of spring-back phenomenon on hardening curves are commented, also.
Resumo:
This paper presents a method to design membrane elements of concrete with orthogonal mesh of reinforcement which are subject to compressive stress. Design methods, in general, define how to quantify the reinforcement necessary to support the tension stress and verify if the compression in concrete is within the strength limit. In case the compression in membrane is excessive, it is possible to use reinforcements subject to compression. However, there is not much information in the literature about how to design reinforcement for these cases. For that, this paper presents a procedure which uses the model based on Baumann's [1] criteria. The strength limits used herein are those recommended by CEB [3], however, a model is proposed in which this limit varies according to the tensile strain which occur perpendicular to compression. This resistance model is based on concepts proposed by Vecchio e Collins [2].
Resumo:
There is no reason for Dentistry to use different terms for phenomena defined in Physics, the specific field in which concepts associated with forces are established and adapted. In place of pressure/tension, the compression/traction pair should be used. This study defines each one of these terms and justifies their use. Our contemporary world demands standardized criteria, methods, measures, concepts and terms to ensure that study protocols, results and applications are used in the same way in any country or area of human action.