6 resultados para SPOT-SIZE CONVERTER
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objective: to evaluate the effects of low-level laser therapy for perineal pain and healing after episiotomy. Design: a double-blind, randomised, controlled clinical trial comparing perineal pain scores and episiotomy healing in women treated with low-level laser therapy (LLLT) and with the simulation of the treatment. Setting: the study was conducted in the Birth Centre and rooming-in units of Amparo Maternal, a maternity service located in the city of Sao Paulo, Brazil. Participants: fifty-two postpartum women who had had mediolateral episiotomies during their first normal delivery were randomly divided into two groups of 26: an experimental group and a control group. Intervention: in the experimental group, the women were treated with LLLT. Irradiation was applied at three points directly on the episiotomy after the suture and in three postpartum sessions: up to 2 hrs postpartum, between 20 and 24 hrs postpartum and between 40 and 48 hrs postpartum. The LLLT was performed with diode laser, with a wavelength of 660 nm (red light), spot size of 0.04 cm(2), energy density of 3.8 J/cm(2), radiant power of 15 mW and 10 s per point, which resulted in an energy of 0.15 J per point and a total energy of 0.45 J per session. The control group participants also underwent three treatment sessions, but without the emission of radiation (simulation group), to assess the possible effects of placebo treatment. Main outcomes: perineal pain scores, rated on a scale from 0 to 10, were evaluated before and immediately after the irradiation in the three sessions. The healing process was assessed using the REEDA scale (Redness, Edema, Echymosis, Discharge Aproximation) before each laser therapy session and 15 and 20 days after the women's discharge. Findings: comparing the pain scores before and after the LLLT sessions, the experimental group presented a significant within-group reduction in mean pain scores after the second and third sessions (p=0.003 and p<0.001, respectively), and the control group showed a significant reduction after the first treatment simulation (p=0.043). However, the comparison of the perineal pain scores between the experimental and control groups indicated no statistical difference at any of the evaluated time points. There was no significant difference in perineal healing scores between the groups. All postpartum women approved of the low-level laser therapy. Conclusions: this pilot study showed that LLLT did not accelerate episiotomy healing. Although there was a reduction in perineal pain mean scores in the experimental group, we cannot conclude that the laser relieved perineal pain. This study led to the suggestion of a new research proposal involving another irradiation protocol to evaluate LLLT's effect on perineal pain relief. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this study was to compare retrospectively the effect of three different treatments on the healing outcome of bisphosphonate-related osteonecrosis of the jaws (BRONJ) in cancer patients. Twenty-two cancer patients were treated for BRONJ with one of the following protocols: clinical (pharmacological therapy), surgical (pharmacological plus surgical therapy), or PRP plus LPT (pharmacological plus surgical plus platelet rich plasma (PRP) plus laser phototherapy (LPT). The laser treatment was applied with a continuous diode laser (InGaAlP, 660 nm) using punctual and contact mode, 40 mW, spot size 0.042 cm(2), 6 J/cm(2) (6 s) and total energy of 0.24 J per point. The irradiations were performed on the exposed bone and surrounding soft tissue. The analysis of demographic data and risk factors was performed by gathering the following information: age, gender, primary tumor, bisphosphonate (BP) used, duration of BP intake, history of chemotherapy, use of steroids, and medical history of diabetes. The association between the current state of BRONJ (with or without bone exposure) and other qualitative variables was determined using the chi-square or Fisher's exact test. In all tests, the significance level adopted was 5%. Most BRONJ lesions occurred in the mandible (77%) after tooth extraction (55%) and in women (72%). A significantly higher percentage of patients reached the current state of BRONJ without bone exposure (86%) in the PPR plus LPT group than in the pharmacological (0%) and surgical (40%) groups after 1-month follow-up assessment. These results suggest that the association of pharmacological therapy and surgical therapy with PRP plus LPT significantly improves BRONJ healing in oncologic patients. Although prospective studies with larger sample sizes are still needed, this preliminary study may be used to inform a better-designed future study. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
The effects of laser focusing and fluence on LIBS analysis of pellets of plant leaves was evaluated. A Q-switched Nd:YAG laser (5ns, 10Hz, 1064nm) was used and the emission signals were collected by lenses into an optical fiber coupled to a spectrometer with Echelle optics and ICCD. Data were acquired from the accumulation of 20 laser pulses at 2.0 mu s delay and 5.0 mu s integration time gate. The emission signal intensities increased with both laser fluence and spot size. Higher sensitivities for Ca, K, Mg, P, Al, B, Cu, Fe, Mn, and Zn determinations were observed for fluences in the range from 25 to 60Jcm(-2). Coefficients of variation of site-to-site measurements were generally lower than 10% (n=30 sites, 20 laser pulses/site) for a fluence of 50Jcm(-2) and 750 mu m spot size. For most elements, there is an indication that accuracy is improved with higher fluences. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Abstract Background It has been speculated that the biostimulatory effect of Low Level Laser Therapy could cause undesirable enhancement of tumor growth in neoplastic diseases. The aim of the present study is to analyze the behavior of melanoma cells (B16F10) in vitro and the in vivo development of melanoma in mice after laser irradiation. Methods We performed a controlled in vitro study on B16F10 melanoma cells to investigate cell viability and cell cycle changes by the Tripan Blue, MTT and cell quest histogram tests at 24, 48 and 72 h post irradiation. The in vivo mouse model (male Balb C, n = 21) of melanoma was used to analyze tumor volume and histological characteristics. Laser irradiation was performed three times (once a day for three consecutive days) with a 660 nm 50 mW CW laser, beam spot size 2 mm2, irradiance 2.5 W/cm2 and irradiation times of 60s (dose 150 J/cm2) and 420s (dose 1050 J/cm2) respectively. Results There were no statistically significant differences between the in vitro groups, except for an increase in the hypodiploid melanoma cells (8.48 ± 1.40% and 4.26 ± 0.60%) at 72 h post-irradiation. This cancer-protective effect was not reproduced in the in vivo experiment where outcome measures for the 150 J/cm2 dose group were not significantly different from controls. For the 1050 J/cm2 dose group, there were significant increases in tumor volume, blood vessels and cell abnormalities compared to the other groups. Conclusion LLLT Irradiation should be avoided over melanomas as the combination of high irradiance (2.5 W/cm2) and high dose (1050 J/cm2) significantly increases melanoma tumor growth in vivo.
Resumo:
The LA-MC-ICP-MS method applied to U-Pb in situ dating is still rapidly evolving due to improvements in both lasers and ICP-MS. To test the validity and reproducibility of the method, 5 different zircon samples, including the standard Temora-2, ranging in age between 2.2 Ga and 246 Ma, were dated using both LA-MC-ICP-MS and SHRIMP. The selected zircons were dated by SHRIMP and, after gentle polishing, the laser spot was driven to the same site or on the same zircon phase with a 213 nm laser microprobe coupled to a multi-collector mixed system. The data were collected with a routine spot size of 25 μm and, in some cases, of 15 and 40 μm. A careful cross-calibration using a diluted U-Th-Pb solution to calculate the Faraday reading to counting rate conversion factors and the highly suitable GJ-1 standard zircon for external calibrations were of paramount importance for obtaining reliable results. All age results were concordant within the experimental errors. The assigned age errors using the LA-MC-ICP-MS technique were, in most cases, higher than those obtained by SHRIMP, but if we are not faced with a high resolution stratigraphy, the laser technique has certain advantages.
Resumo:
Objectives: The objective of this study was to apply low-level laser therapy (LLLT) to accelerate the recovery process of a child patient with Bell's palsy (BP). Design: This was a prospective study. Subject: The subject was a three-year-old boy with a sudden onset of facial asymmetry due to an unknown cause. Materials and methods: The low-level laser source used was a gallium aluminum arsenide semiconductor diode laser device (660nm and 780 nm). No steroids or other medications were given to the child. The laser beam with a 0.04-cm2 spot area, and an aperture with approximately 1-mm diameter, was applied in a continuous emission mode in direct contact with the facial area. The duration of a laser session was between 15 and 30 minutes, depending on the chosen points and the area being treated. Light was applied 10 seconds per point on a maximum number of 80 points, when the entire affected (right) side of the face was irradiated, based on the small laser beam spot size. According to the acupuncture literature, this treatment could also be carried out using 10-20 Chinese acupuncture points, located unilaterally on the face. In this case study, more points were used because the entire affected side of the face (a large area) was irradiated instead of using acupuncture points. Outcome measures: The House-Brackmann grading system was used to monitor the evolution of facial nerve motor function. Photographs were taken after every session, always using the same camera and the same magnitude. The three-year-old boy recovered completely from BP after 11 sessions of LLLT. There were 4 sessions a week for the first 2 weeks, and the total treatment time was 3 weeks. Results: The result of this study was the improvement of facial movement and facial symmetry, with complete reestablishment to normality. Conclusions: LLLT may be an alternative to speed up facial normality in pediatric BP.