5 resultados para Right to Self-Determination

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Warfarin-dosing pharmacogenetic algorithms have presented different performances across ethnicities, and the impact in admixed populations is not fully known. Aims: To evaluate the CYP2C9 and VKORC1 polymorphisms and warfarin-predicted metabolic phenotypes according to both self-declared ethnicity and genetic ancestry in a Brazilian general population plus Amerindian groups. Methods: Two hundred twenty-two Amerindians (Tupinikin and Guarani) were enrolled and 1038 individuals from the Brazilian general population who were self-declared as White, Intermediate (Brown, Pardo in Portuguese), or Black. Samples of 274 Brazilian subjects from Sao Paulo were analyzed for genetic ancestry using an Affymetrix 6.0 (R) genotyping platform. The CYP2C9*2 (rs1799853), CYP2C9*3 (rs1057910), and VKORC1 g.-1639G>A (rs9923231) polymorphisms were genotyped in all studied individuals. Results: The allelic frequency for the VKORC1 polymorphism was differently distributed according to self-declared ethnicity: White (50.5%), Intermediate (46.0%), Black (39.3%), Tupinikin (40.1%), and Guarani (37.3%) (p < 0.001), respectively. The frequency of intermediate plus poor metabolizers (IM + PM) was higher in White (28.3%) than in Intermediate (22.7%), Black (20.5%), Tupinikin (12.9%), and Guarani (5.3%), (p < 0.001). For the samples with determined ancestry, subjects carrying the GG genotype for the VKORC1 had higher African ancestry and lower European ancestry (0.14 +/- 0.02 and 0.62 +/- 0.02) than in subjects carrying AA (0.05 +/- 0.01 and 0.73 +/- 0.03) (p = 0.009 and 0.03, respectively). Subjects classified as IM + PM had lower African ancestry (0.08 +/- 0.01) than extensive metabolizers (0.12 +/- 0.01) (p = 0.02). Conclusions: The CYP2C9 and VKORC1 polymorphisms are differently distributed according to self-declared ethnicity or genetic ancestry in the Brazilian general population plus Amerindians. This information is an initial step toward clinical pharmacogenetic implementation, and it could be very useful in strategic planning aiming at an individual therapeutic approach and an adverse drug effect profile prediction in an admixed population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Religious communities have been a challenge to HIV prevention globally. Focusing on the acceptability component of the right to health, this intervention study examined how local Catholic, Evangelical and Afro-Brazilian religious communities can collaborate to foster young people`s sexual health and ensure their access to comprehensive HIV prevention in their communities in Brazil. This article describes the process of a three-stage sexual health promotion and HIV prevention initiative that used a multicultural human rights approach to intervention. Methods included 27 in-depth interviews with religious authorities on sexuality, AIDS prevention and human rights training of 18 young people as research-agents, who surveyed 177 youth on the same issues using self-administered questionnaires. The results, analysed using a rights-based perspective on health and the vulnerability framework, were discussed in daylong interfaith workshops. Emblematic of the collaborative process, workshops are the focus of the analysis. Our findings suggest that this human rights framework is effective in increasing inter-religious tolerance and in providing a collective understanding of the sexuality and prevention needs of youth from different religious communities, and also serves as a platform for the expansion of state AIDS programmes based on laical principles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Losartan is an antihypertensive agent that lost its patent protection in 2010, and, consequently, it has been available in generic form. The latter motivated the search for a rapid and precise alternative method. Here, a simple conductometric titration in aqueous medium is described for the losartan analysis in pharmaceutical formulations. The first step of the titration occurs with the protonation of losartan producing a white precipitate and resulting in a slow increase in conductivity. When the protonation stage is complete, a sharp increase in conductivity occurs which was determined to be due to the presence of excess of acid. The titrimetric method was applied to the determination of losartan in pharmaceutical products and the results are comparable with values obtained using a chromatographic method recommended by the United States Pharmacopoeia. The relative standard deviation for successive measurements of a 125 mg L-1 (2.71x10(-4) mol L-1) losartan solution was approximately 2%. Recovery study in tablet samples ranged between 99 and 102.4%. The procedure is fast, simple, and represents an attractive alternative for losartan quantification in routine analysis. In addition, it avoids organic solvents, minimizes the risk of exposure to the operator, and the waste treatment is easier compared to classical chromatographic methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: This study evaluated the degree of conversion (DC) and working time (WT) of two commercial, dual-cured resin cements polymerized at varying temperatures and under different curing-light accessible conditions, using Fourier transformed infrared analysis (FTIR). Materials and Methods: Calibra (Cal; Dentsply Caulk) and Variolink II (Ivoclar Vivadent) were tested at 25 degrees C or preheated to 37 degrees C or 50 degrees C and applied to a similar-temperature surface of a horizontal attenuated-total-reflectance unit (ATR) attached to an infrared spectrometer. The products were polymerized using one of four conditions: direct light exposure only (600 mW/cm(2)) through a glass slide or through a 1.5- or 3.0-mm-thick ceramic disc (A2 shade, IPS e.max, Ivoclar Vivadent) or allowed to self-cure in the absence of light curing. FTIR spectra were recorded for 20 min (1 spectrum/s, 16 scans/spectrum, resolution 4 cm(-1)) immediately after application to the ATR. DC was calculated using standard techniques of observing changes in aliphatic-to-aromatic peak ratios precuring and 20-min postcuring as well as during each 1-second interval. Time-based monomer conversion analysis was used to determine WT at each temperature. DC and WT data (n=6) were analyzed by two-way analysis of variance and Tukey post hoc test (p=0.05). Results: Higher temperatures increased DC regardless of curing mode and product. For Calibra, only the 3-mm-thick ceramic group showed lower DC than the other groups at 25 degrees C (p=0.01830), while no significant difference was observed among groups at 37 degrees C and 50 degrees C. For Variolink, the 3-mm-thick ceramic group showed lower DC than the 1-mm-thick group only at 25 degrees C, while the self-cure group showed lower DC than the others at all temperatures (p=0.00001). WT decreased with increasing temperature: at 37 degrees C near 70% reduction and at 50 degrees C near 90% for both products, with WT reduction reaching clinically inappropriate times in some cases (p=0.00001). Conclusion: Elevated temperature during polymerization of dual-cured cements increased DC. WT was reduced with elevated temperature, but the extent of reduction might not be clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cloud point extraction (CPE) was employed for separation and preconcentration prior to the determination of nickel by graphite furnace atomic absorption spectrometry (GFAAS), flame atomic absorption spectrometry (FAAS) or UV-Vis spectrophotometry. Di-2-pyridyl ketone salicyloylhydrazone (DPKSH) was used for the first time as a complexing agent in CPE. The nickel complex was extracted from the aqueous phase using the Triton X-114 surfactant. Under optimized conditions, limits of detection obtained with GFAAS, FAAS and UV-Vis spectrophotometry were 0.14, 0.76 and 1.5 mu g L-1, respectively. The extraction was quantitative and the enrichment factor was estimated to be 27. The method was applied to natural waters, hemodialysis concentrates, urine and honey samples. Accuracy was evaluated by analysis of the NIST 1643e Water standard reference material.