12 resultados para Restraint System Tests.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

For many tree species, mating system analyses have indicated potential variations in the selfing rate and paternity correlation among fruits within individuals, among individuals within populations, among populations, and from one flowering event to another. In this study, we used eight microsatellite markers to investigate mating systems at two hierarchical levels (fruits within individuals and individuals within populations) for the insect pollinated Neotropical tree Tabebuia roseo-alba. We found that T. roseo-alba has a mixed mating system with predominantly outcrossed mating. The outcrossing rates at the population level were similar across two T. roseo-alba populations; however, the rates varied considerably among individuals within populations. The correlated paternity results at different hierarchical levels showed that there is a high probability of shared paternal parentage when comparing seeds within fruits and among fruits within plants and full-sibs occur in much higher proportion within fruits than among fruits. Significant levels of fixation index were found in both populations and biparental inbreeding is believed to be the main cause of the observed inbreeding. The number of pollen donors contributing to mating was low. Furthermore, open-pollinated seeds varied according to relatedness, including half-sibs, full-sibs, self-sibs and self- half-sibs. In both populations, the effective population size within a family (seed-tree and its offspring) was lower than expected for panmictic populations. Thus, seeds for ex situ conservation genetics, progeny tests and reforestation must be collected from a large number of seed-trees to guarantee an adequate effective population in the sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present study, we investigated the involvement of beta-adrenoceptors in the medial amygdaloid nucleus (MeA) in cardiovascular responses evoked in rats submitted to an acute restraint stress. We first pretreated Wistar rats with the nonselective beta-adrenoceptor antagonist propranolol microinjected bilaterally into the MeA (10, 15, and 20 nmol/100 nL) 10 min before exposure to acute restraint. The pretreatment with propranolol did not affect the blood pressure (BP) increase evoked by restraint. However, it increased the tachycardiac response caused by acute restraint when animals were pretreated with a dose of 15 nmol, without a significant effect on the BP response. This result indicates that beta-adrenoceptors in the MeA have an inhibitory influence on restraint-evoked heart rate (HR) changes. Pretreatment with the selective beta(2)-adrenoceptor antagonist ICI 118,551 (10, 15, and 20 nmol/100 nL) significantly increased the restraint-evoked tachycardiac response after doses of 15 and 20 nmol, an effect that was similar to that observed after the pretreatment with propranolol at a dose of 15 nmol, without a significant effect on the BP response. Pretreatment of the MeA with the selective beta(1)-adrenoceptor antagonist CGP 20712 (10, 15, and 20 nmol/100 nL) caused an opposite effect on the HR response, and a significant decrease in the restraint-evoked tachycardia was observed only after the dose of 20 nmol, without a significant effect on the BP response. Because propranolol is an equipotent antagonist of both beta(1) and beta(2)-adrenoceptors, and opposite effects were observed after the treatment with the higher doses of the selective antagonists ICI 118,551 and CGP 20712, the narrow window in the dose-response to propranolol could be explained by a functional antagonism resulting from the simultaneous inhibition of beta(1) and beta(2)-adrenoceptors by the treatment with propranolol. The present results suggest that beta(2)-adrenoceptors have an inhibitory influence on the restraint-evoked tachycardiac response, whereas beta(1)-adrenoceptors have a facilitatory influence on the restraint-evoked tachycardiac response. (c) 2012 IBRO. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. The aim of this study is to critically evaluate the bond strength (BS) of Glass-Ionomer Cements (GIC) to dentine with microtensile (mu TBS) and microshear (mu SBS) BS tests by assessing their rankings and failure patterns. Methods. Samples were made on flat dentine surfaces and submitted to mTBS and mSBS. The materials used were: high viscosity GIC (Ketac (TM) Molar Aplicap-KM), resin-modified GIC (Fuji II-FII), nano-filled resin-modified GIC (Ketac (TM) N100-N100) and an etch-and-rinse adhesive system with a composite resin (Adper (TM) Single Bond 2 and Z100 (TM)-Z100). All tests were performed with a Universal Testing Machine (24 h water storage, crosshead speed of 1 mm/min). Debonded surfaces were examined with a stereomicroscope (x40) to identify the failure mode. The data was analyzed with two-way ANOVA (p < 0.05) and LSD test. Results. Means were statistically different regarding the tests and materials, indicating that values for BS obtained for each material depend on the test performed. Failure analysis revealed that failures produced by mTBS were mainly cohesive for KM and FII. mu SBS failures were mainly adhesive or mixed for all materials. For the mTBS, the rank was Z100 > FII > KM = N100, whereas for the mSBS it was Z100 = FII = KM > N100. Conclusion: It may be concluded that distinct micro-mechanical tests present different failure patterns and rankings depending on the material to be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the application of Linear Matrix Inequalities to the robust and optimal adjustment of Power System Stabilizers with pre-defined structure. Results of some tests show that gain and zeros adjustments are sufficient to guarantee robust stability and performance with respect to various operating points. Making use of the flexible structure of LMI's, we propose an algorithm that minimizes the norm of the controllers gain matrix while it guarantees the damping factor specified for the closed loop system, always using a controller with flexible structure. The technique used here is the pole placement, whose objective is to place the poles of the closed loop system in a specific region of the complex plane. Results of tests with a nine-machine system are presented and discussed, in order to validate the algorithm proposed. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Medial amygdaloid nucleus (MeA) neurotransmission has an inhibitory influence on cardiovascular responses in rats submitted to restraint, which are characterized by both elevated blood pressure (BP) and intense heart rate (HR) increase. In the present study, we investigated the involvement of MeA adrenoceptors in the modulation of cardiovascular responses that are observed during an acute restraint. Male Wistar rats received bilateral microinjections of the selective alpha 1-adrenoceptor antagonist WB4101 (10, 15, and 20 nmol/100 nL) or the selective alpha 2-adrenoceptor antagonist RX821002 (10, 15, and 20 nmol/nL) into the MeA, before the exposure to acute restraint. The injection of WB4101 reduced the restraint-evoked tachycardia. In contrast, the injection of RX821002 increased the tachycardia. Both drugs had no influence on BP increases observed during the acute restraint. Our findings indicate that alpha 1 and alpha 2-adrenoceptors in the MeA play different roles in the modulation of the HR increase evoked by restraint stress in rats. Results suggest that alpha 1-adrenoceptors and alpha 2-adrenoceptors mediate the MeA-related facilitatory and inhibitory influences on restraint-related HR responses, respectively. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The vestibular-ocular reflex assessment is important, but not enough. Tridimensional electromagnetic sensor systems represent a new method to assess posturography. Aim: To assess body sway in healthy subjects who had positive Dix Hallpike and Epley maneuvers and with other vestibular dysfunctions by means of a three-dimensional system. Study design: Prospective. Materials and Methods: We had 23 healthy women, 15 with peripheral vestibular dysfunction found upon caloric test and 10 with positive Epley and Dix Hallpike maneuvers. All tests performed in the following positions: open and closed eyes on stable and unstable surfaces. Results: With the Eyes Open and on a stable surface, p < 0.01 between the control group and the one with peripheral vestibular dysfunction in all variables, except the a-p maximum, full speed and mediolateral trajectory velocity, which had a p < 0.01 between the group with vestibular dysfunction and controls in all positions. The group with positive Epley and Dix Hallpike maneuvers had p < 0.01 at full speed and in its components in the x and y in positions with open and eyes closed on an unstable surface. Conclusion: The tridimensional electromagnetic sensors system was able to generate reliable information about body sway in the study volunteers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports the results of full-scale tests in beam-to-column connections for composite slim floor systems, including tests on Bare Steel connection and composite connection. The tested system consists of a concrete-filled composite column and a composite floor where an asymmetric steel beam is connected to a composite column by shear steel plates. Tests results previously obtained on partially encased composite beams were used to define the position of the headed studs in the slim floor system. Based on the obtained results of connections, the composite and Bare Steel connection behaved as semi-rigid and nominally pinned respectively. The tests results also indicated a significant contribution of the slim floor to the moment capacity of the connection. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trigeneration systems have been used with advantage in the last years in distributed electricity generation systems as a function of a growth of natural gas pipeline network distribution system, tax incentives, and energy regulation policies. Typically, a trigeneration system is used to produce electrical power simultaneously with supplying heating and cooling load by recovering the combustion products thermal power content that otherwise would be driven to atmosphere. Concerning that, two small scale trigeneration plants have been tested for overall efficiency evaluation and operational comparison. The first system is based on a 30 kW (ISO) natural gas powered microturbine, and the second one uses a 26 kW natural gas powered internal combustion engine coupled to an electrical generator as a prime mover. The stack gases from both machines were directed to a 17.6 kW ammonia-water absorption refrigeration chiller for producing chilled water first and next to a water heat recovery boiler in order to produce hot water. Experimental results are presented along with relevant system operational parameters for appropriate operation including natural gas consumption, net electrical and thermal power production, i.e., hot and cold water production rates, primary energy saving index, and the energy utilization factor over total and partial electrical load operational conditions. (c) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to assess re-hospitalization rates of individuals with psychosis and bipolar disorder and to study determinants of readmission. Methods: Prospective observational study, conducted in Sao Paulo, Brazil. One hundred-sixty-nine individuals with bipolar and psychotic disorder in need of hospitalization in the public mental health system were followed for 12 months after discharge. Their families were contacted by telephone and interviews were conducted at 1, 2, 6 and 12 months post-discharge to evaluate readmission rates and factors related. Results: One-year re-hospitalization rate was of 42.6%. Physical restraint during hospital stay was a risk factor (OR = 5.4-10.5) for readmission in most models. Not attending consultations after discharge was related to the 12-month point readmission (OR = 8.5, 95% CI 2.3-31.2) and to the survival model (OR = 3.2, 95% CI 1.5-7.2). Number of previous admissions was a risk factor for the survival model (OR = 6.6-11.9). Family's agreement with permanent hospitalization of individuals with mental illness was the predictor associated to readmission in all models (OR = 3.5-10.9) and resulted in shorter survival time to readmission; those readmitted were stereotyped as dangerous and unhealthy. Conclusions: Family's stigma towards mental illness might contribute to the increase in readmission rates of their relatives with psychiatric disorders. More studies should be conducted to depict mechanisms by which stigma increases re-hospitalization rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess re-hospitalization rates of individuals with psychosis and bipolar disorder and to study determinants of readmission. METHODS: Prospective observational study, conducted in São Paulo, Brazil. One hundred-sixty-nine individuals with bipolar and psychotic disorder in need of hospitalization in the public mental health system were followed for 12 months after discharge. Their families were contacted by telephone and interviews were conducted at 1, 2, 6 and 12 months post-discharge to evaluate readmission rates and factors related. RESULTSOne-year re-hospitalization rate was of 42.6%. Physical restraint during hospital stay was a risk factor (OR = 5.4-10.5) for readmission in most models. Not attending consultations after discharge was related to the 12-month point readmission (OR = 8.5, 95%CI 2.3-31.2) and to the survival model (OR = 3.2, 95%CI 1.5-7.2). Number of previous admissions was a risk factor for the survival model (OR = 6.6-11.9). Family's agreement with permanent hospitalization of individuals with mental illness was the predictor associated to readmission in all models (OR = 3.5-10.9) and resulted in shorter survival time to readmission; those readmitted were stereotyped as dangerous and unhealthy. CONCLUSIONS: Family's stigma towards mental illness might contribute to the increase in readmission rates of their relatives with psychiatric disorders. More studies should be conducted to depict mechanisms by which stigma increases re-hospitalization rates.