2 resultados para Red Cross

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate the nature of extremely red galaxies (ERGs), objects whose colours are redder than those found in the red sequence present in colour–magnitude diagrams of galaxies. We selected from the Sloan Digital Sky Survey Data Release 7 a volume-limited sample of such galaxies in the redshift interval 0.010 < z < 0.030, brighter than Mr = −17.8 (magnitudes dereddened, corrected for the Milky Way extinction) and with (g − r) colours larger than those of galaxies in the red sequence. This sample contains 416 ERGs, which were classified visually. Our classification was cross-checked with other classifications available in the literature. We found from our visual classification that the majority of objects in our sample are edge-on spirals (73 per cent). Other spirals correspond to 13 per cent, whereas elliptical galaxies comprise only 11 per cent of the objects. After comparing the morphological mix and the distributions of Hα/Hβ and axial ratios of ERGs and objects in the red sequence, we suggest that dust, more than stellar population effects, is the driver of the red colours found in these extremely red galaxies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low level laser therapy (LLLT) is used in several applications, including the reduction of inflammatory processes. It might be used to prevent the systemic inflammatory response syndrome (SIRS), which some patients develop after cardiopulmonary bypass (CPB) surgery. The objectives of this study were to investigate light distribution inside blood, in order to implement the LLLT during CPB, and, through this study, to determine the best wavelength and the best way to perform the treatment. The blood, diluted to the same conditions of CPB procedure was contained inside a cuvette and an optical fiber was used to collect the scattered light. Two wavelengths were used: 632.8 nm and 820 nm. Light distribution in blood inside CPB tubes was also evaluated. Compared to the 820 nm light, the 632.8 nm light is scattered further away from the laser beam, turning it possible that a bigger volume of blood be treated. The blood should be illuminated through the smallest diameter CPB tube, using at least four distinct points around it, in only one cross section, because the blood is kept passing through the tube all the time and the whole volume will be illuminated.