21 resultados para Rational medicine use

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background. Acute normovolemic hemodilution (ANH) is an alternative to blood transfusion in surgeries involving blood loss. This experimental study was designed to evaluate whether pulse pressure variation (PPV) would be an adequate tool for monitoring changes in preload during ANH, as assessed by transesophageal echocardiography. Methods. Twenty-one anesthetized and mechanically ventilated pigs were randomized into three groups: CTL (control), HES (hemodilution with 6% hydroxyethyl starch at a 1:1 ratio) or NS (hemodilution with saline 0.9% at a 3:1 ratio). Hemodilution was performed in animals of groups NS and HES in two stages, with target hematocrits 22% and 15%, achieved at 30-minute intervals. After two hours, 50% of the blood volume withdrawn was transfused and animals were monitored for another hour. Statistical analysis was based on ANOVA for repeated measures followed by multiple comparison test (P<0.05). Pearson's correlations were performed between changes in left ventricular end-diastolic volume (LVEDV) and PPV, central venous pressure (CVP) and pulmonary artery occlusion pressure (PAOP). Results. Group NS received a significantly greater amount of fluids during ANH (NS, 900 +/- 168 mL vs. HES, 200 +/- 50 mL, P<0.05) and presented greater urine output (NS, 2643 +/- 1097mL vs. HES, 641 +/- 338mL, P<0.001). Significant decreases in LVEDV were observed in group NS from completion of ANH until transfusion. In group HES, only increases in LVEDV were observed, at the end of ANH and at transfusion. Such changes in LVEDV (Delta LVEDV) were better reflected by changes in PPV (Delta PPV, R=-0.62) than changes in CVP (Delta CVP R=0.32) or in PAOP (Delta PAOP, R=0.42, respectively). Conclusion. Changes in preload during ANH were detected by changes in PPV. Delta PPV was superior to Delta PAOP and Delta CVP to this end. (Minerva Anestesiol 2012;78:426-33)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: The objective of the study was to evaluate the ability of large-volume cone-beam computed tomography (CBCT) to detect horizontal root fracture and to test the influence of a metallic post. Methods: Through the examination of 40 teeth by large-volume CBCT (20-cm height and 15-cm diameter cylinder) at 0.2-mm voxel resolution, 2 observers analyzed the samples for the presence and localization of horizontal root fracture. Results: The values of accuracy in the groups that had no metallic post ranged from 33%-68%, whereas for the samples with the metallic post, values showed a wide variation (38%-83%). Intraobserver agreement showed no statistically significant difference between the groups with/without metallic post; both ranged from very weak to weak (kappa, 0.09-0.369). Conclusions: The low accuracy and low intraobserver and interobserver agreement reflect the difficulty in performing an adequate diagnosis of horizontal root fractures through a large-volume CBCT by using a small voxel reconstruction. (J Endod 2012;38:856-859)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. The purpose of this study was to evaluate the reactivity and polymerization kinetics behavior of a model dental adhesive resin with water-soluble initiator systems. Methods. A monomer blend based on Bis-GMA, TEGDMA and HEMA was used as a model dental adhesive resin, which was polymerized using a thioxanthone type (QTX) as a photoinitiator. Binary and ternary photoinitiator systems were formulated using 1 mol% of each initiator. The co-initiators used in this study were ethyl 4-dimethylaminobenzoate (EDAB), diphenyliodonium hexafluorophosphate (DPIHFP), 1,3-diethyl-2-thiobarbituric acid (BARB), p-toluenesulfinic acid and sodium salt hydrate (SULF). Absorption spectra of the initiators were measured using a UV-Vis spectrophotometer, and the photon absorption energy (PAE) was calculated. The binary system camphorquinone (CQ)/amine was used as a reference group (control). Twelve groups were tested in triplicate. Fourier-transform infrared spectroscopy (FTIR) was used to investigate the polymerization reaction during the photoactivation period to obtain the degree of conversion (DC) and maximum polymerization rate (R-p(max)) profile of the model resin. Results. In the analyzed absorption profiles, the absorption spectrum of QTX is almost entirely localized in the UV region, whereas that of CQ is in the visible range. With respect to binary systems, CQ + EDAB exhibited higher DC and R-p(max) values. In formulations that contained ternary initiator systems, the group CQ + QTX + EDAB was the only one of the investigated experimental groups that exhibited an R-p(max) value greater than that of CQ + EDAB. The groups QTX + EDAB + DPIHFP and QTX + DPIHFP + SULF exhibited values similar to those of CQ + EDAB with respect to the final DC; however, they also exhibited lower reactivity. Significance. Water-soluble initiator systems should be considered as alternatives to the widely used CQ/amine system in dentin adhesive formulations. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To conduct a controlled study contrasting titanium surface topography after procedures that simulated 10 years of brushing using toothpastes with or without fluoride. Methods: Commercially pure titanium (cp Ti) and Ti-6Al-4V disks (6 mm circle divide x 4 mm) were mirror-polished and treated according to 6 groups (n = 6) as a function of immersion (I) or brushing (B) using deionised water (W), fluoride-free toothpaste (T) and fluoride toothpaste (FT). Surface topography was evaluated at baseline (pretreatment) and post-treatment, using atomic force microscope in order to obtain three-dimensional images and mean roughness. Specimens submitted to immersion were submerged in the vehicles without brushing. For brushed specimens, procedures were conducted using a linear brushing machine with a soft-bristled toothbrush. Immersion and brushing were performed for 244 h. IFT and BFT samples were analysed under scanning electron microscope with Energy-Dispersive X-ray Spectroscopy (EDS). Pre and post-treatment values were compared using the paired Student T-test (alpha = .05). Intergroup comparisons were conducted using one-way ANOVA with Tukey post-test (alpha = .05). Results: cp Ti mean roughness (in nanometers) comparing pre and post-treatment were: IW, 2.29 +/- 0.55/2.33 +/- 0.17; IT, 2.24 +/- 0.46/2.02 +/- 0.38; IFT, 2.22 +/- 0.53/1.95 +/- 0.36; BW, 2.22 +/- 0.42/3.76 +/- 0.45; BT, 2.27 +/- 0.55/16.05 +/- 3.25; BFT, 2.27 +/- 0.51/22.39 +/- 5.07. Mean roughness (in nanometers) measured in Ti-6Al-4V disks (pre/post-treatment) were: IW, 1.79 +/- 0.25/2.01 +/- 0.25; IT, 1.61 +/- 0.13/1.74 +/- 0.19; IFT, 1.92 +/- 0.39/2.29 +/- 0.51; BW, 2.00 +/- 0.71/2.05 +/- 0.43; BT, 2.37 +/- 0.86/11.17 +/- 2.29; BFT, 1.83 +/- 0.50/15.73 +/- 1.78. No significant differences were seen after immersions (p > .05). Brushing increased the roughness of cp Ti and of Ti-6Al-4V (p < .01); cp Ti had topographic changes after BW, BT and BFT treatments whilst Ti-6Al-4V was significantly different only after BT and BTF. EDS has not detected fluoride or sodium ions on metal surfaces. Conclusions: Exposure to toothpastes (immersion) does not affect titanium per se; their use during brushing affects titanium topography and roughness. The associated effects of toothpaste abrasives and fluorides seem to increase roughness on titanium brushed surfaces. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To investigate the periapical tissue response of 4 different retrograde root-filling materials, ie, intermediate restorative material, thermoplasticized gutta-percha, reinforced zinc oxide cement (Super-EBA), and mineral trioxide aggregate (MTA), in conjunction with an ultrasonic root-end preparation technique in an animal model. Materials and Methods: Vital roots of the third and fourth right mandibular premolars in 6 healthy mongrel dogs were apicectomized and sealed with 1 of the materials using a standardized surgical procedure. After 120 days, the animals were sacrificed and the specimens were analyzed radiologically, histologically, and scanning electron microscopically. The Fisher exact test was performed on the 2 outcome values. Results: Twenty-three sections were analyzed histologically. Evaluation showed better re-establishment of the periapical tissues and generally lower inflammatory infiltration in the sections from teeth treated with the intermediate restorative material and the MTA. New root cement on the resected dentin surfaces was seen on all sections regardless of the used material. New hard tissue formation, directly on the surface of the material, was seen only in the MTA sections. There was no statistical difference in outcome among the tested materials. Conclusions: The results from this dog model favor the intermediate restorative material and MTA as retrograde fillings when evaluating the bone defect regeneration. MTA has the most favorable periapical tissue response when comparing the biocompatibility of the materials tested. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:2041-2047, 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: To optimize patient functioning, rehabilitation professionals often rely on measurements of functioning as well as on classifications. Although the International Classification of Diseases (ICD) and the International Classification of Functioning, Disability and Health (ICF) are used, their joint use has yet to become an established practice. To encourage their joint use in daily practice, the World Health Organization (WHO) has invited all rehabilitation practitioners worldwide to support the ICD-11 revision process by identifying the ICF categories that correspond to specific rehabilitation-relevant health conditions. The first step in completing this task, generating the list of these health conditions, was taken at a February 2012 workshop in Sao Paulo, Brazil. Objectives: The objectives of this paper are to present the results of the Sao Paulo workshop, and to invite practitioners to participate in the ICD-ICF joint use initiative. Discussion: Alternating plenary and small working group sessions were held and 103 rehabilitation-relevant health conditions were identified. With this list available, WHO together with the International Society of Physical and Rehabilitation Medicine (ISPRM), is reaching out to clinicians of all rehabilitation disciplines to take on the challenge of identifying the ICF categories for at least one of the health conditions listed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: The aim of the current study was to compare the objective and subjective effects of continuous positive airway pressure to the use of nasal dilator strips in patients with acromegaly and moderate to severe obstructive sleep apnea. METHODS: We studied 12 patients with acromegaly and moderate to severe obstructive sleep apnea (male/females = 8/4, age = 52 +/- 8 ys, body mass index = 33.5 +/- 4.6 Kg/m(2), apnea-hypopnea index = 38 +/- 14 events/h) who had been included in a randomized, crossover study to receive three months of treatment with continuous positive airway pressure and nasal dilator strips. All patients were evaluated at study entry and at the end of each treatment by polysomnography, and Epworth Sleepiness Scale, Pittsburgh Sleep Quality Index and treatment satisfaction questionnaires. ClinicalTrials.gov: NCT01265121 RESULTS: The apnea-hypopnea index values decreased significantly with continuous positive airway pressure treatment but did not change with the use of nasal dilator strips. All of the subjective symptoms improved with both treatments, but these improvements were significantly greater with continuous positive airway pressure than with the nasal dilator strips. CONCLUSION: The use of nasal dilator strips had a much smaller effect on the severity of obstructive sleep apnea in patients with acromegaly and moderate to severe obstructive sleep apnea in comparison to the use of continuous positive airway pressure. Moreover, the improvement in several subjective parameters without any significant objective improvement in obstructive sleep apnea resulting from the use of nasal dilator strips is compatible with a placebo effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports the case of a patient with a severely resorbed mandible who was treated without a bone graft, using short implants, internal rigid fixation, rhBMP-2 and beta-tricalcium phosphate. A 76-year-old woman, with a severely resorbed mandible (less than 3 mm), reported a history of nearly 25 years of complete edentulism and consecutive treatment failures, with total bilateral exposed inferior alveolar nerves and complete bone resorption of the inferior border in some areas. The treatment of choice was the placement of a 2.0 mm thick unilock bone plate (MatrixMandible, Synthes Maxillofacial, Paoli, PA, USA), to reinforce the mandible. Eight short implants with a regular platform (Nobel Biocare, Goteborg, Sweden) were placed: three on the external oblique line on both sides and two on the symphysis. In order to augment mandible height and coat the exposed thread of the anterior implants, rhBMP-2 (Infuse Bone, Meditronic Sofamor Danek, Memphis, TN, USA) and beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) were used. Four 1.3 mm L miniplates were placed to support the graft. 14 months after surgery, the patient was satisfied and had excellent function without complications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: There are no current guidelines for diagnosing and managing mild prenatal hydronephrosis. Variations in physician approach make it difficult to analyze outcomes and establish optimal management. We determined the variability of diagnostic approach and management regarding prenatal hydronephrosis among maternal-fetal medicine obstetricians, pediatric urologists and pediatric radiologists. Materials and Methods: Online surveys were sent to mailing lists for national societies for each specialty. Participants were surveyed regarding criteria for diagnosing mild prenatal hydronephrosis and recommendations for postnatal management, including use of antibiotic prophylaxis, followup scheduling and type of followup imaging. Results: A total of 308 maternal-fetal medicine obstetricians, 126 pediatric urologists and 112 pediatric radiologists responded. Pediatric urologists and radiologists were divided between Society for Fetal Urology criteria and use of anteroposterior pelvic diameter for diagnosis, while maternal-fetal medicine obstetricians preferred using the latter. For postnatal evaluation radiologists preferred using personal criteria, while urologists preferred using anteroposterior pelvic diameter or Society for Fetal Urology grading system. There was wide variation in the use of antibiotic prophylaxis among pediatric urologists. Regarding the use of voiding cystourethrography/radionuclide cystography in patients with prenatal hydronephrosis, neither urologists nor radiologists were consistent in their recommendations. Finally, there was no agreement on length of followup for mild prenatal hydronephrosis. Conclusions: We observed a lack of uniformity regarding grading criteria in diagnosing hydronephrosis prenatally and postnatally among maternal-fetal medicine obstetricians, pediatric urologists and pediatric radiologists. There was also a lack of agreement on the management of mild intermittent prenatal hydronephrosis, resulting in these cases being managed inconsistently. A unified set of guidelines for diagnosis, evaluation and management of mild intermittent prenatal hydronephrosis would allow more effective evaluation of outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim: To evaluate the effect of a space-maintaining device fixed to the lateral wall of the maxillary sinus after the elevation of the sinus mucosa on bone filling of the sinus cavity. Material and methods: Immediately after the elevation of the maxillary sinus Schneiderian membrane accomplished through lateral antrostomy in four monkeys, a titanium device was affixed to the lateral sinus wall protruding into the sinus cavity to maintain the mucosa elevated without the use of grafting material. The healing of the tissue around the implants was evaluated after 3 and 6 months. Ground sections were prepared and analyzed histologically. Results: The void under the elevated sinus membrane, originally filled with the blood clot, was reduced after 3 as well as after 6 months of healing of about 56% and 40.5%, respectively. In seven out of eight cases, the devices had perforated the sinus mucosa. The formation of mineralized bone and bone marrow amounted to about 42% and 69% after 3 and 6 months, respectively. The connective tissue represented about 53% and 23% of the newly formed tissue after 3 and 6 months, respectively. Conclusions: New bone formation was found below the devices. However, shrinkage of the newly formed tissue was observed both after 3 and 6 months of healing. Hence, the space-maintaining function of the devices used in the present study has to be questioned.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Tuberculosis (TB) remains a public health issue worldwide. The lack of specific clinical symptoms to diagnose TB makes the correct decision to admit patients to respiratory isolation a difficult task for the clinician. Isolation of patients without the disease is common and increases health costs. Decision models for the diagnosis of TB in patients attending hospitals can increase the quality of care and decrease costs, without the risk of hospital transmission. We present a predictive model for predicting pulmonary TB in hospitalized patients in a high prevalence area in order to contribute to a more rational use of isolation rooms without increasing the risk of transmission. Methods: Cross sectional study of patients admitted to CFFH from March 2003 to December 2004. A classification and regression tree (CART) model was generated and validated. The area under the ROC curve (AUC), sensitivity, specificity, positive and negative predictive values were used to evaluate the performance of model. Validation of the model was performed with a different sample of patients admitted to the same hospital from January to December 2005. Results: We studied 290 patients admitted with clinical suspicion of TB. Diagnosis was confirmed in 26.5% of them. Pulmonary TB was present in 83.7% of the patients with TB (62.3% with positive sputum smear) and HIV/AIDS was present in 56.9% of patients. The validated CART model showed sensitivity, specificity, positive predictive value and negative predictive value of 60.00%, 76.16%, 33.33%, and 90.55%, respectively. The AUC was 79.70%. Conclusions: The CART model developed for these hospitalized patients with clinical suspicion of TB had fair to good predictive performance for pulmonary TB. The most important variable for prediction of TB diagnosis was chest radiograph results. Prospective validation is still necessary, but our model offer an alternative for decision making in whether to isolate patients with clinical suspicion of TB in tertiary health facilities in countries with limited resources.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leprosy is an infectious disease caused by Mycobacterium leprae. The polymerase chain reaction (PCR) has been applied to detect M. leprae in different clinical samples and urine seems to be attractive for this purpose. PCR was used to improve the sensitivity for diagnosing leprosy by amplifying a 151-bp PCR fragment of the M. leprae pra gene (PCR-Pra) in urine samples. Seventy-three leprosy patients (39 males and 34 females, 14 to 78 years old) were selected for leprosy diagnosis at a reference laboratory in Maringa, PR, Brazil. Of these, 36 were under anti-leprosy multidrug therapy with dapsone and rifampicin for tuberculoid (TT) and dapsone, rifampicin and clofazimine for borderline (BB) and lepromatous (LL) forms. The control group contained 50 healthy individuals without any clinical history of leprosy. DNA isolated from leprosy patients' urine samples was successfully amplified by PCR-Pra in 46.6% (34/73) of the cases. The positivity of PCR-Pra for patients with the TT form was 75% for both patients under treatment and non-treated patients (P = 0.1306). In patients with the LL form, PCR-Pra positivity was 52 and 30% for patients under treatment and non-treated patients, respectively (P = 0.2386). PCR-Pra showed a statistically significant difference in detecting M. leprae between the TT and LL forms of leprosy in patients under treatment (P = 0.0033). Although the current study showed that the proposed PCR-Pra has some limitations in the detection of M. leprae, this method has the potential to be a useful tool for leprosy diagnosis mainly in TT leprosy where the AFB slit-skin smear is always negative.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. Matrices of unsplinted attachment systems are generally reported to be the weak component of implant overdentures, often requiring frequent maintenance. Clinical wear results in reduced retention of the prosthesis, requiring activation or renewal of the matrix to restore the initial level of retention. Purpose. The purpose of this retrospective study was to measure the wear of the matrix of a ball attachment after various periods of clinical wear. Material and methods. Seventy specimens of 3 groups of matrices of ball attachments that had been in use for mean periods of 12.3 months (1Y group, n=26), 39.0 months (3Y group, n=28) and 95.6 months (8Y group, n=16) were retrieved from 35 patients (2 specimens per patient) and measured on a coordinate measuring machine equipped with a touch trigger probe. Ten unused matrices were used as controls (CTRL group). The external and internal matrix diameters and deviations from circularity were measured. For the various time periods, the decreases in matrix thickness were calculated and compared with controls. Kruskal-Wallis 1-way ANOVA by ranks, followed by the Mann-Whitney post hoc tests, were conducted to test for differences in median values among groups (alpha=.05). Results. For the internal upper diameter of the matrices tested, the Kruskal-Wallis and Mann-Whitney tests revealed significant differences for the 3 groups compared to the controls. For group 1Y, a significant difference (P<.001) of the internal upper diameter was found compared to the CTRL group. Compared to the controls, the nonparametric analyses for groups 3Y and 8Y showed significant differences for the internal upper diameter (P<.001) and deviations from circularity (P<.001). For groups 1Y, 3Y and 8Y, matrix thickness losses were 07, 47 and 70 pm, respectively. Conclusions. Within the limitations of this study, it was observed that one year of clinical wear had limited effect on the ball attachment matrices. Three to 8 years of clinical use resulted in a significant decrease of matrix thickness, especially at the tip of the retentive lamellae. (J Prosthet Dent 2012;107:191-198)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Acute bronchiolitis is a leading cause of infant hospitalization and is most commonly caused by respiratory syncytial virus. Etiological tests are not required for its diagnosis, but the influence of viral screening on the therapeutic approach for acute bronchiolitis remains unclear. METHODS: A historical cohort was performed to assess the impact of viral screening on drug prescriptions. The study included infants up to one year of age who were hospitalized for bronchiolitis. Virus screening was performed using immunofluorescence assays in nasopharyngeal aspirates. The clinical data were obtained from the patients' medical records. Therapeutic changes were considered to be associated with viral screening when made within 24 hours of the release of the results. RESULTS: The frequency of prescriptions for beta agonists, corticosteroids and antibiotics was high at the time of admission and was similar among the 230 patients. The diagnosis of pneumonia and otitis was associated with the introduction of antibiotics but did not influence antibiotics maintenance after the results of the virus screening were obtained. Changes in the prescriptions were more frequent for the respiratory syncytial virus patients compared to patients who had negative viral screening results (p=0.004), especially the discontinuation of antibiotics (p<0.001). The identification of respiratory syncytial virus was associated with the suspension of antibiotics (p=0.003), even after adjusting for confounding variables (p=0.004); however, it did not influence the suspension of beta-agonists or corticosteroids. CONCLUSION: The identification of respiratory syncytial virus in infants with bronchiolitis was independently associated with the discontinuation of antibiotics during hospitalization.