13 resultados para RIGID FIXATION

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study reports the case of a patient with a severely resorbed mandible who was treated without a bone graft, using short implants, internal rigid fixation, rhBMP-2 and beta-tricalcium phosphate. A 76-year-old woman, with a severely resorbed mandible (less than 3 mm), reported a history of nearly 25 years of complete edentulism and consecutive treatment failures, with total bilateral exposed inferior alveolar nerves and complete bone resorption of the inferior border in some areas. The treatment of choice was the placement of a 2.0 mm thick unilock bone plate (MatrixMandible, Synthes Maxillofacial, Paoli, PA, USA), to reinforce the mandible. Eight short implants with a regular platform (Nobel Biocare, Goteborg, Sweden) were placed: three on the external oblique line on both sides and two on the symphysis. In order to augment mandible height and coat the exposed thread of the anterior implants, rhBMP-2 (Infuse Bone, Meditronic Sofamor Danek, Memphis, TN, USA) and beta-tricalcium phosphate (Cerasorb; Curasan, Kleinostheim, Germany) were used. Four 1.3 mm L miniplates were placed to support the graft. 14 months after surgery, the patient was satisfied and had excellent function without complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Among the osteotomies performed in orthognathic surgery, the sagittal osteotomy of the mandibular ramus (SOMR) is the most common, allowing a great range of movements and stable internal fixation (SIF), therefore eliminating the need of maxillomandibular block in the postoperative period. Objectives: The purpose of this study was to evaluate the biomechanical resistance of three national systems used for SIF in SOMR in sheep mandibles. Material and methods: The study was performed in 30 sheep hemi-mandibles randomly divided into 3 experimental groups, each containing 10 hemi-mandibles. The samples were measured to avoid discrepancies and then subjected to SOMR with 5-mm advancement. In group I, 2.0x12 mm screws were used for fixation, inserted in an inverted "L" pattern (inverted "L" group). In group II, fixation was performed with two 2.0x12 mm screws, positioned in a linear pattern and a 4-hole straight miniplate and four 2.0x6.0 mm monocortical screws (hybrid group). In group III, fixation was performed with two-hole straight miniplates and eight 2.0x6.0 mm monocortical screws (mini plate group). All materials used for SIF were supplied by Osteosin - SIN. The hemimandibles were subjected to vertical linear load test by Kratos K2000MP mechanical testing unit for loading registration and displacement. Results: All groups showed similar resistance during mechanical test for loading and displacement, with no statistically significant differences between groups according to analysis of variance. Conclusion: These results indicate that the three techniques of fixation are equally effective for clinical fixation of SOMR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to compare the bone repair along a mandibular body osteotomy stabilized with 2.0 mm absorbable and metallic systems. 12 male, adult mongrel dogs were divided into two groups (metallic and absorbable) and subjected to unilateral osteotomy between the mandibular third and fourth premolars, which was stabilized by applying two 4-hole plates. At 2 and 18 weeks, three dogs from each group were killed and the osteotomy sites were removed and divided equally into three parts: the upper part was labelled the tension third (TT), the lower part the compression third (CT), and the part between the TT and CT the intermediary third (IT). Regardless of the treatment system, union between the fragments was observed at 18 weeks and the CT showed more advanced stages of bone repair than the TT. Histometric analysis did not reveal any significant differences among the 3 parts or systems in the distance between bone fragments at 2 weeks. Although at 18 weeks the proportions of newly formed bone did not differ among TT, IT and CT, significantly enhanced bone formation was observed in all sections for the metallic group. The patterns of repair were distinct between treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We tested the short-term effects of a nonrigid tool, identified as an "anchor system" (e.g., ropes attached to varying weights resting on the floor), on the postural stabilization of blindfolded adults with and without intellectual disabilities (ID). Participants held a pair of anchors one in each hand, under three weight conditions (250 g, 500 g and 1,000 g), while they performed a restricted balance task (standing for 30 s on a balance beam placed on top of a force platform). These conditions were called anchor practice trials. Before and after the practice trials, a condition without anchors was tested. Control practice groups, who practiced blocks of trials without anchors, included individuals with and without ID. The anchor system improved subjects' balance during the standing task, for both groups. For the control groups, the performance of successive trials in the condition without the anchor system showed no improvement in postural stability. The individuals with intellectual disability, as well as their peers without ID, used the haptic cues of nonrigid tools (i.e., the anchor system) to stabilize their posture, and the short-term stabilizing effects appeared to result from their previous use of the anchor system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intensive scheduling in sports requires athletes to resume physical activity shortly after injury. The purpose of this study was to investigate early isokinetic muscle strength and knee function on bone-patellar tendon-bone (BPTB) ACL reconstruction with double femoral pin fixation or interference screw technique. A prospective study was conducted from 2008 to 2009, with 48 athletes who received femoral BPTB fixation with interference screw (n = 26) or double pin (n = 22). Clinical (IKDC objective score and hop test) and isokinetic muscle strength (peak torque (PT), PT/body weight and flexion/extension rate (F/E) in 60 and 240A degrees/s) were analyzed at 6 months of follow-up. Analysis at baseline showed no differences between groups before surgery related to age, gender, associated injury, Tegner or Lysholm score; thus showing that groups were similar. During follow-up, however, there were significant differences between the two groups in some of the isokinetic muscle strength: PT/BW 60A degrees/s (Double Pin = 200% +/- A 13% vs. Interference Screw = 253% +/- A 16%*, *P = 0.01); F/E 60A degrees/s (Double Pin = 89% +/- A 29%* vs. Interference Screw = 74% +/- A 12%, *P = 0.04). No statistical differences between groups were observed on IKDC objective score, hop test and complications. The significant muscle strength outcome of the interference screw group found in this study gives initial evidence that this fixation technique is useful for athletes that may need accelerated rehabilitation. Early return to sports ability signaled by isokinetic muscle strength is of clinical relevance as it is one of the main goals for athletes' rehabilitation. III.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of sewage sludge is a highly promising practice for the development of sustainable agricultural systems. The objective of this study was to evaluate doses of sewage sludge composted with and without Rhizobium inoculation in leaf N content, nodule number, nodule dry weight and plant during flowering. The experiment was conducted in the greenhouse of the Department of Soil Science and Natural Resources College of Agricultural Sciences of Botucatu, using as substrate used in vessels of 30 liters a Red Yelow Latosol sandy texture with experimental design adopted was randomized blocks constituted for 10 treatments and five doses of composted sewage sludge (0, 10, 20, 30, 40 t ha(-1)) with or without inoculation Bradyrhizobium japonic with three replications. There was an increase in the number and dry weight of nodules and shoot dry mass of soybeans due to the increase of the dose of sludge up to a dose of 20 t ha(-1) and after this dose there was a decrease of these parameters. At a dose of 10 t ha(-1) sludge compost inoculated seeds showed higher for foliar concentrations of N and number of nodules compared with uninoculated seeds. At a dose of 30 t ha(-1) inoculated seeds were higher compared to uninoculated in all parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Primary and secondary stabilities of immediately loaded mandibular implants restored with fixed prostheses (FP) using rigid or semirigid splinting systems were clinically and radiographically evaluated. Methods: Fifteen edentulous patients were rehabilitated using hybrid FP; each had 5 implants placed between the mental foramens. Two groups were randomly divided: group 1-FP with the conventional rigid bar splinting the implants and group 2-semi-rigid cantilever extension system with titanium bars placed in the 2 distal abutment cylinders. Primary stability was evaluated using resonance frequency analysis after installation of the implant abutments. The measurements were made at 3 times: T0, at baseline; T1, 4 months after implant placement; and T2, 8 months after implant placement. Presence of mobility and inflammation in the implant surrounding regions were checked. Stability data were submitted to statistical analysis for comparison between groups (P, 0.05). Results: Implant survival rate for the implants was of 100% in both groups. No significant differences in the mean implant stability quotient values were found for both groups from baseline and after the 8-month follow-up. Conclusion: The immediate loading of the implants was satisfactory, and both splinting conditions (rigid and semi-rigid) can be successfully used for the restoration of edentulous mandibles. (Implant Dent 2012;21:486-490)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study is to evaluate the differences on FTIR spectra of the normal lung cell (noncancerous mice lung epithelial cell line e10) due to different fixation protocols for histological processing. The results shown that formalin and methacarn (normally used in fixation) did cause many changes on the FTIR spectra of mice lung cells e10, mainly in the organic compounds (800-1800 cm(-1)) in lipids, DNA, and proteins, and the alcohol 70% fixation protocol caused almost no changes on the FTIR spectra compared to unfixed cells spectra (in PBS). It can be concluded that histological processing with alcohol 70% fixation protocol can be used in the FTIR study of mice lung cell line e10.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The bone tissue responses to Cyanoacrylate have been described in the literature, but none used N-butyl-2-cyanoacrilate (NB-Cn) for bone graft fixation. Purpose: The aims of the study were: (a) to analyze the bone grafts volume maintenance fixed either with NB-Cn or titanium screw; (b) to assess the incorporation of onlay grafts on perforated recipient bed; and (c) the differences of expression level of tartrate-resistant acid phosphatase (TRAP) protein involved in bone resorption. Materials and Methods: Eighteen New Zealand White rabbits were submitted to calvaria onlay grafting on both sides of the mandible. On one side, the graft was fixed with NB-Cn, while on the other hand the bone graft was secured with an osteosynthesis screw. The computed tomography (CT) was performed just after surgery and at animals sacrifice, after 1 (n = 9) and 6 weeks (n = 9), in order to estimate the bone grafts volume along the experiments. Histological sections of the grafted areas were prepared to evaluate the healing of bone grafts and to assess the expression of TRAP protein. Results: The CT scan showed better volume maintenance of bone grafts fixed with NB-Cn (p = 0.05) compared with those fixed with screws, in both experimental times (analysis of variance). The immunohistochemical evaluation showed that the TRAP expression in a 6-week period was significantly higher compared with the 1-week period, without showing significant difference between the groups (Wilcoxon and MannWhitney). Histological analysis revealed that the NB-Cn caused periosteum damage, but provided bone graft stabilization and incorporation similar to the control group. Conclusion: The perforation provided by screw insertion into the graft during fixation may have triggered early revascularization and remodeling to render increased volume loss compared with the experimental group. These results indicate that the NB-Cn possesses equivalent properties to titanium screw to be used as bone fixation material in osteosynthesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The metabolic capacity for nitrogen fixation is known to be present in several prokaryotic species scattered across taxonomic groups. Experimental detection of nitrogen fixation in microbes requires species-specific conditions, making it difficult to obtain a comprehensive census of this trait. The recent and rapid increase in the availability of microbial genome sequences affords novel opportunities to re-examine the occurrence and distribution of nitrogen fixation genes. The current practice for computational prediction of nitrogen fixation is to use the presence of the nifH and/or nifD genes. Results Based on a careful comparison of the repertoire of nitrogen fixation genes in known diazotroph species we propose a new criterion for computational prediction of nitrogen fixation: the presence of a minimum set of six genes coding for structural and biosynthetic components, namely NifHDK and NifENB. Using this criterion, we conducted a comprehensive search in fully sequenced genomes and identified 149 diazotrophic species, including 82 known diazotrophs and 67 species not known to fix nitrogen. The taxonomic distribution of nitrogen fixation in Archaea was limited to the Euryarchaeota phylum; within the Bacteria domain we predict that nitrogen fixation occurs in 13 different phyla. Of these, seven phyla had not hitherto been known to contain species capable of nitrogen fixation. Our analyses also identified protein sequences that are similar to nitrogenase in organisms that do not meet the minimum-gene-set criteria. The existence of nitrogenase-like proteins lacking conserved co-factor ligands in both diazotrophs and non-diazotrophs suggests their potential for performing other, as yet unidentified, metabolic functions. Conclusions Our predictions expand the known phylogenetic diversity of nitrogen fixation, and suggest that this trait may be much more common in nature than it is currently thought. The diverse phylogenetic distribution of nitrogenase-like proteins indicates potential new roles for anciently duplicated and divergent members of this group of enzymes.