6 resultados para Pulse Width Modulation (PWM)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence has been used in many applications of magnetic resonance imaging (MRI) and low-resolution NMR (LRNMR) spectroscopy. Recently. CPMG was used in online LRNMR measurements that use long RF pulse trains, causing an increase in probe temperature and, therefore, tuning and matching maladjustments. To minimize this problem, the use of a low-power CPMG sequence based on low refocusing pulse flip angles (LRFA) was studied experimentally and theoretically. This approach has been used in several MRI protocols to reduce incident RF power and meet the specific absorption rate. The results for CPMG with LRFA of 3 pi/4 (CPMG(135)), pi/2 (CPMG(90)) and pi/4 (CPMG(45)) were compared with conventional CPMG with refocusing pi pulses. For a homogeneous field, with linewidth equal to Delta nu = 15 Hz, the refocusing flip angles can be as low as pi/4 to obtain the transverse relaxation time (T(2)) value with errors below 5%. For a less homogeneous magnetic field. Delta nu = 100 Hz, the choice of the LRFA has to take into account the reduction in the intensity of the CPMG signal and the increase in the time constant of the CPMG decay that also becomes dependent on longitudinal relaxation time (T(1)). We have compared the T(2) values measured by conventional CPMG and CPMG(90) for 30 oilseed species, and a good correlation coefficient, r = 0.98, was obtained. Therefore, for oilseeds, the T(2) measurements performed with pi/2 refocusing pulses (CPMG(90)), with the same pulse width of conventional CPMG, use only 25% of the RF power. This reduces the heating problem in the probe and reduces the power deposition in the samples. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.
Auditory brainstem implant outcomes and MAP parameters: Report of experiences in adults and children
Resumo:
The auditory brainstem implant (ABI) was first developed to help neurofibromatosis type 2 patients. Recently, its use has been recently extended to adults with non-tumor etiologies and children with profound hearing loss who were not candidates for a cochlear implant (Cl). Although the results has been extensively reported, the stimulation parameters involved behind the outcomes have received less attention. Objective: The aim of this study is to describe the audiologic outcomes and the MAP parameters in ABI adults and children at our center. Methods: Retrospective chart review. Five adults and four children were implanted with the ABI24M from September 2005 to June 2009. In the adult patients, four had Neurofibromatosis type 2, and one had postmeningitic deafness with complete ossification of both cochleae. Three of the children had cochlear malformation or dysplasia, and one had complete ossified cochlea due to meningitis. Map parameters as well as the intraoperative electrical auditory brainstem responses were collected. Evaluation was performed with at least six months of device use and included free-field hearing thresholds, speech perception tests in the adult patients and for the children, the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) and (ESP) were used to evaluate the development of auditory skills, besides the MUSS to evaluate. Results: The number of active electrodes that did not cause any non-auditory sensation varied from three to nineteen. All of them were programmed with SPEAK strategy, and the pulse widths varied from 100 to 300 mu s. Free-field thresholds with warble tones varied from very soft auditory sensation of 70 dBHL at 250 Hz to a pure tone average of 45 dBHL. Speech perception varied from none to 60% open-set recognition of sentences in silence in the adult population and from no auditory sensation at all to a slight improvement in the IT-MAIS/MAIS scores. Conclusion: We observed that ABI may be a good option for offering some hearing attention to both adults and children. In children, the results might not be enough to ensure oral language development. Programming the speech processor in children demands higher care to the audiologist. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Introduction: Laser hair removal is becoming an increasingly popular alternative to traditional methods such as shaving, waxing, among other methods. Semiconductor diode lasers are considered the most efficient light sources available and are especially well suited for clinical applications including hair reduction. The effectiveness of laser hair reduction depends on many variables, including the skin type of the patient. Material and Methods: A patient with Fitzpatrick Skin Type IV was submitted to laser hair removal of the arms with a high-power diode laser system with long pulses with a wavelength of 800 nm, a fluence of 40 J/cm2 and a pulse width of 20 ms. A 12-month follow-up assessment was performed and included photography and questionnaire. Results: Hypopigmentation was observed after a single laser hair removal section. After 6 months with the area totally covered, a gradual suntan with a sun screen lotion with an SPF of 15 was prescribed by the dermatologist. After 12 months of the initial treatment, a complete recovery of the hypopigmentation was achieved. Conclusion: Although a safe procedure, lasers for hair removal may be associated with adverse side effects including undesired pigment alterations. Before starting a laser hair removal treatment, patients seeking the eradication of hair should be informed that temporary, and possibly permanent, pigmentary changes may occur.
Resumo:
Fibromyalgia (FM) is characterized by chronic non-inflammatory widespread pain (CWP) and changes in sympathetic function. In attempt to elucidate the pathophysiological mechanisms of FM we used a well-established CWP animal model. We aimed to evaluate changes in cardiac autonomic balance and baroreflex function in response to CWP induction in rats. CWP was induced by two injections of acidic saline (pH 4.0, n = 8) five days apart into the left gastrocnemius muscle. Control animals were injected twice with normal saline (pH 7.2, n = 6). One day after the second injection of acidic saline or normal saline, the animals had pulse interval (PI) and systolic arterial pressure (SAP) variability, and spontaneous baroreflex sensitivity (BRS) evaluated. After induction of CWP, there was an increase of power in the low frequency (LF) band of PI spectrum (12.75 +/- 1.04 nu), a decrease in the high frequency (HF) band (87.25 +/- 1.04 nu) and an increase of LF/HF ratio (0.16 +/- 0.01), when compared to control animals (7.83 +/- 1.13 nu LF; 92.16 +/- 1.13 nu HF; 0.08 +/- 0.01 LF/HF). In addition, there was an increase of power in the LF band of SAP spectrum (7.93 +/- 1.39 mmHg(2)) when compared to control animals (2.97 +/- 0.61 mmHg(2)). BRS was lower in acidic saline injected rats (0.59 +/- 0.06 ms/mmHg) when compared to control animals (0.71 +/- 0.03 ms/mmHg). Our results showed that induction of CWP in rats shifts cardiac sympathovagal balance towards sympathetic predominance and decreases BRS. These data corroborate findings in humans with FM. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Oxygen-deficient TiO2 films with enhanced visible and near-infrared optical absorption have been deposited by reactive sputtering using a planar diode radio frequency magnetron configuration. It is observed that the increase in the absorption coefficient is more effective when the O-2 gas supply is periodically interrupted rather than by a decrease of the partial O-2 gas pressure in the deposition plasma. The optical absorption coefficient at 1.5 eV increases from about 1 x 10(2) cm(-1) to more than 4 x 10(3) cm(-1) as a result of the gas flow discontinuity. A red-shift of similar to 0.24 eV in the optical absorption edge is also observed. High resolution transmission electron microscopy with composition analysis shows that the films present a dense columnar morphology, with estimated mean column width of 40nm. Moreover, the interruptions of the O-2 gas flow do not produce detectable variations in the film composition along its growing direction. X-ray diffraction and micro-Raman experiments indicate the presence of the TiO2 anatase, rutile, and brookite phases. The anatase phase is dominant, with a slight increment of the rutile and brookite phases in films deposited under discontinued O-2 gas flow. The increase of optical absorption in the visible and near-infrared regions has been attributed to a high density of defects in the TiO2 films, which is consistent with density functional theory calculations that place oxygen-related vacancy states in the upper third of the optical bandgap. The electronic structure calculation results, along with the adopted deposition method and experimental data, have been used to propose a mechanism to explain the formation of the observed oxygen-related defects in TiO2 thin films. The observed increase in sub-bandgap absorption and the modeling of the corresponding changes in the electronic structure are potentially useful concerning the optimization of efficiency of the photocatalytic activity and the magnetic doping of TiO2 films. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4724334]