4 resultados para Processing steps

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A polarimetric X-band radar has been deployed during one month (April 2011) for a field campaign in Fortaleza, Brazil, together with three additional laser disdrometers. The disdrometers are capable of measuring the raindrop size distributions (DSDs), hence making it possible to forward-model theoretical polarimetric X-band radar observables at the point where the instruments are located. This setup allows to thoroughly test the accuracy of the X-band radar measurements as well as the algorithms that are used to correct the radar data for radome and rain attenuation. For the campaign in Fortaleza it was found that radome attenuation dominantly affects the measurements. With an algorithm that is based on the self-consistency of the polarimetric observables, the radome induced reflectivity offset was estimated. Offset corrected measurements were then further corrected for rain attenuation with two different schemes. The performance of the post-processing steps was analyzed by comparing the data with disdrometer-inferred polarimetric variables that were measured at a distance of 20 km from the radar. Radome attenuation reached values up to 14 dB which was found to be consistent with an empirical radome attenuation vs. rain intensity relation that was previously developed for the same radar type. In contrast to previous work, our results suggest that radome attenuation should be estimated individually for every view direction of the radar in order to obtain homogenous reflectivity fields.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports the implementation of GMPs in a mozzarella cheese processing plant. The mozzarella cheese manufacturing unit is located in the Southwestern region of the state of Parana, Brazil, and processes 20,000 L of milk daily. The implementation of GMP took place with the creation of a multi-disciplinary team and it was carried out in four steps: diagnosis, report of the diagnosis and road map, corrective measures and follow-up of GMP implementation. The effectiveness of actions taken and GMP implementation was compared by the total percentages of non-conformities and conformities before and after implementation of GMR Microbiological indicators were also used to assess the implementation of GMP in the mozzarella cheese processing facility. Results showed that the average percentage of conformity after the implementation of GMP was significant increased to 66%, while before it was 32% (p < 0.05). The populations of aerobic microorganisms and total coliforms in equipment were significantly reduced (p < 0.05) after the implementation of GMP, as well as the populations of total coliforms in the hands of food handlers (p < 0.05). In conclusion, GMP implementation changed the overall organization of the cheese processing unity, as well as managers and food handlers' behavior and knowledge on the quality and safety of products manufactured. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton nuclear magnetic resonance (H-1 NMR) spectroscopy for detection of biochemical changes in biological samples is a successful technique. However, the achieved NMR resolution is not sufficiently high when the analysis is performed with intact cells. To improve spectral resolution, high resolution magic angle spinning (HR-MAS) is used and the broad signals are separated by a T-2 filter based on the CPMG pulse sequence. Additionally, HR-MAS experiments with a T-2 filter are preceded by a water suppression procedure. The goal of this work is to demonstrate that the experimental procedures of water suppression and T-2 or diffusing filters are unnecessary steps when the filter diagonalization method (FDM) is used to process the time domain HR-MAS signals. Manipulation of the FDM results, represented as a tabular list of peak positions, widths, amplitudes and phases, allows the removal of water signals without the disturbing overlapping or nearby signals. Additionally, the FDM can also be used for phase correction and noise suppression, and to discriminate between sharp and broad lines. Results demonstrate the applicability of the FDM post-acquisition processing to obtain high quality HR-MAS spectra of heterogeneous biological materials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes the development of a visual stimulus generator to be used in neuroscience experiments with invertebrates such as flies. The experiment consists in the visualization of a fixed image that is displaced horizontally according to the stimulus data. The system is capable of displaying 640 x 480 pixels with 256 intensity levels at 200 frames per second (FPS) on conventional raster monitors. To double the possible horizontal positioning possibilities from 640 to 1280, a novel technique is presented introducing artificial inter-pixel steps. The implementation consists in using two video frame buffers containing each a distinct view of the desired image pattern. This implementation generates a visual effect capable of doubling the horizontal positioning capabilities of the visual stimulus generator allowing more precise and movements more contiguous. (C) 2011 Elsevier Inc. All rights reserved.