18 resultados para Prótese dentária. Zircônia. Resíduo. Uniaxial. Isostática. Zirkonzahn

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Treatment of patients with cleft lip and palate is completed with fixed prostheses, removable, total, implants and aims to restore aesthetics, phonetics and function and should be guided by the basic principles of oral rehabilitation, such as physiology, stability, aesthetics, hygiene and the expectations of the patient. In order to obtain longevity of a prosthetic rehabilitation, the periodontal and dental tissue as well as the biomechanics of the prosthesis are to be respected. The purpose of this article is to describe the types of prosthetics treatment, which are performed at HRAC/USP for the rehabilitation of cleft area in adult patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From a recent perspective the morse-taper dental implants connections are increasingly being used as an alternative for replacement of a missing teeth. Nevertheless, there are a large variety of prosthetic components available on the market with some limitations regarding the final prothesis. This article demonstrated the difficulties and limitations of prosthesis implant-retained connections when using morse-taper implants (with a prosthetic index) case in which the surgical placement of the implant wasn’t successfully performed. The alternative to overcome this scenario was the technique using the tube screw over the top of a mini abutment component. It was possible to manufacture and to have satisfactory adaptation, achieving the satisfaction of the patient, restoring function and esthetics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: This study compared the resistance to fracture of endodontically treated teeth restored with different intraradicular posts with different lengths and full coverage metallic crowns. Methods: Sixty extracted human canine teeth were randomly divided into 6 groups. Groups CP5, CP75 and CP10 were restored using custom cast post and core (CP) and groups PF5, PF75 and PF10 were restored with provisional pre-fabricated tin post (PF) and composite resin core at 5 mm, 7.5 mm and 10 mm of intraradicular length, respectively. The specimens were submitted to dynamic cyclic loading and those that resisted to this load were submitted to load compression using a universal testing machine. Compressive load was applied at a 45-degree angle to the long axis of the tooth until failure. Results: Kruskal-Wallis one-way analysis of variance by ranks showed statistically significant differences among the groups (p<0.0001). However, when the means were compared using the Tukey’s test, significant differences were noted between groups CP5 and CP10 and between groups CP10 and PF5. All groups presented root fractures and post displacements during mechanical cycling. All teeth in groups CP5 and PF5 failed the dynamic cycling test. Conclusions: This study showed that increasing intraradicular post length also increases resistance to fracture of endodontically treated teeth. On the other hand, most endodontically treated teeth restored with pre-fabricated tin posts (provisional posts) failed in the dynamic cycling test

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the impact of global and/or local strain engineering techniques on tri-gate p- and nMuGFETs performance is experimentally evaluated. Multiple gate structures were analyzed through basic and analog performance parameters for four different splits processed with different strain-engineering techniques (unstrained, uniaxial, biaxial and uniaxial+biaxial stress). While n-channel devices with narrow fins present a worse analog behavior, biaxial stress promotes the electron mobility for larger devices increasing the voltage gain. Besides the voltage gain, the transconductance, output conductance and Early Voltage are also evaluated. Although pMuGFETs are less affected by the strain engineering, they present better analog behavior for all studied devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lyotropic liquid crystalline quaternary mixtures of potassium laurate (KL), potassium sulphate (K2SO4)/alcohol (n-OH)/water, with the alcohols having different numbers of carbon atoms in the alkyl chain (n), from 1-octanol to 1-hexadecanol, were investigated by optical techniques (optical microscopy and laser conoscopy). The biaxial nematic phase domain is present in a window of values of n = n(KL) +/- 2, where n(KL) = 11 is the number of carbon atoms in the alkyl chain of KL. The biaxial phase domain became smaller and the uniaxial-to-biaxial phase transition temperatures shifted to relatively higher temperatures upon going from 1-nonanol to 1-tridecanol. Moreover, compared with other lyotropic mixtures these new mixtures present high birefringence values, which we expect to be related to the micellar shape anisotropy. Our results are interpreted assuming that alcohol molecules tend to segregate in the micelles in a way that depends on the relative value of n with respect to nKL. The larger the value of n, the more alcohol molecules tend to be located in the curved parts of the micelle, favoring the uniaxial nematic calamitic phase with respect to the biaxial and uniaxial discotic nematic phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding how magnetic materials respond to rapidly varying magnetic fields, as in dynamic hysteresis loops, constitutes a complex and physically interesting problem. But in order to accomplish a thorough investigation, one must necessarily consider the effects of thermal fluctuations. Albeit being present in all real systems, these are seldom included in numerical studies. The notable exceptions are the Ising systems, which have been extensively studied in the past, but describe only one of the many mechanisms of magnetization reversal known to occur. In this paper we employ the Stochastic Landau-Lifshitz formalism to study high-frequency hysteresis loops of single-domain particles with uniaxial anisotropy at an arbitrary temperature. We show that in certain conditions the magnetic response may become predominantly out-of-phase and the loops may undergo a dynamic symmetry loss. This is found to be a direct consequence of the competing responses due to the thermal fluctuations and the gyroscopic motion of the magnetization. We have also found the magnetic behavior to be exceedingly sensitive to temperature variations, not only within the superparamagnetic-ferromagnetic transition range usually considered, but specially at even lower temperatures, where the bulk of interesting phenomena is seen to take place. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The world's largest ethanol producer (USA) uses corn as feedstock. DDGS (distillers dried grains with solubles) is the main waste generated from this process (around 32 million t/year). DDGS samples were pyrolyzed at 1000 ºC in a furnace with controlled atmosphere. The effluent was channeled to a second furnace, in which catalyst substrates were placed. Chromatographic analysis was used to evaluate the gaseous effluents, showing that the catalyst reduced hydrocarbon emissions. The solid products formed were analyzed by SEM and TEM. Graphitic structures and carbon nanofibers, 50 µm in length and with diameters of 80-200 nm, were formed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esse trabalho estuda a viabilidade técnica da fabricação de cimento com uma mistura de resíduo proveniente da serragem de blocos de granito e escória de aciaria LD. Para isso, foi preparada uma mistura desses materiais de modo que a relação %CaO / %SiO2 fosse 1,2. Essa mistura foi fundida e resfriada rapidamente em água. A amostra foi caracterizada e o difratograma de raios X mostrou um material amorfo e a presença das fases mineralógicas Akermanita e Gehlenita, as quais são consideradas como as fases mineralógicas ideais para a atividade hidráulica. Essa mistura foi adicionada ao clínquer para a fabricação de cimento. Com o cimento fabricado, foram feitos ensaios cujos resultados são apresentados e comparados com os valores obtidos para o cimento de alto-forno. Esses resultados indicam a viabilidade técnica da utilização da mistura na fabricação de cimento.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo do presente estudo foi analisar como a prevalência e a distribuição da cárie dentária influenciam o tamanho da amostra em levantamentos epidemiológicos, e os custos para sua realização. Foram utilizados dados de levantamentos realizados em escolares de 12 anos em Bauru nos anos de 1976, 1984, 1990, 1994 e 2001, e em Piracicaba nos anos de 2001 e 2005. Os tamanhos amostrais foram dimensionados considerando-se a média e o desvio padrão obtidos, fixando-se erro amostral em 1%, 2%, 5% e 10%. Os custos foram estimados considerando material permanente, de consumo e recursos humanos. Verificou-se aumento no tamanho das amostras em ambos os municípios, variando de 119 em 1976 para 1.118 em 2001 em Bauru, e de 954 em 2001 para 1.252 em 2005 em Piracicaba, considerando-se um erro amostral de 10%. Considerando-se diferentes erros amostrais, verificou-se o custo para o levantamento, sendo que o mesmo depende do quanto o pesquisador se permite errar em relação ao verdadeiro valor da média da população. Conclui-se que a diminuição da prevalência da cárie dentária determinou o aumento no tamanho das amostras e a elevação dos custos para realização dos levantamentos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo ilustra o impacto da calcinação de resíduo de bauxita (RB) nas propriedades de suspensões formuladas com cimento Portland, tanto no estado fresco como no endurecido. As suspensões foram avaliadas contendo uma razão constante de água-cimento e teor de resíduo variando de 5% a 20% em peso e em substituição ao cimento. As propriedades reológicas e a resistência mecânica foram alteradas em função do aumento do teor de RB, mas a calcinação não teve influência no resultado final obtido, seja no estado fresco ou no endurecido. Assim, pode-se afirmar que a utilização de resíduo de bauxita, natural ou calcinada, em formulações com cimento Portland pode reduzir o consumo de cimento, sendo uma alternativa para a utilização de uma grande quantidade deste tipo de resíduo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: A maioria dos pacientes com perda auditiva, incluindo casos de perdas severas, é beneficiada com o uso de aparelho de amplificação sonora individual. Acredita-se que o implante coclear estabeleça melhores resultados na reabilitação de uma criança com perda auditiva nos casos em que a gravidade da deficiência torna os aparelhos acústicos convencionais incapazes de fornecer informação sonora adequada, já que estes necessitam de reserva coclear suficiente para que ocorra detecção acústica. OBJETIVO: Avaliar se em pacientes portadores de surdez pré-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. SÍNTESE DOS DADOS: Revisão sistemática realizada a partir de consulta a artigos científicos selecionados por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Entre os 2169 artigos consultados, 12 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Entre os desenhos de estudos analisados na revisão, 7 são do tipo coorte prospectivo e 5 são estudos transversais. CONCLUSÃO: O implante coclear demonstrou, através de diversos estudos, ser atualmente, a melhor alternativa para os casos de perdas auditivas bilaterais severas ou profundas, atingindo resultados superiores em percepção e desenvolvimento de fala em crianças pré-linguais quando comparados aos aparelhos de amplificação sonora convencionais.