3 resultados para Polarization value (Pr)

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a simultaneous optical signal-to-noise ratio (OSNR) and differential group delay (DGD) monitoring method based on degree of polarization (DOP) measurements in optical communications systems. For the first time in the literature (to our best knowledge), the proposed scheme is demonstrated to be able to independently and simultaneously extract OSNR and DGD values from the DOP measurements. This is possible because the OSNR is related to maximum DOP, while DGD is related to the ratio between the maximum and minimum values of DOP. We experimentally measured OSNR and DGD in the ranges from 10 to 30 dB and 0 to 90 ps for a 10 Gb/s non-return-to-zero signal. A theoretical analysis of DOP accuracy needed to measure low values of DGD and high OSNRs is carried out, showing that current polarimeter technology is capable of yielding an OSNR measurement within 1 dB accuracy, for OSNR values up to 34 dB, while DGD error is limited to 1.5% for DGD values above 10 ps. For the first time to our knowledge, the technique was demonstrated to accurately measure first-order polarization mode dispersion (PMD) in the presence of a high value of second-order PMD (as high as 2071 ps(2)). (C) 2012 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electronic polarization induced by the interaction of a reference molecule with a liquid environment is expected to affect the magnetic shielding constants. Understanding this effect using realistic theoretical models is important for proper use of nuclear magnetic resonance in molecular characterization. In this work, we consider the pyridine molecule in water as a model system to briefly investigate this aspect. Thus, Monte Carlo simulations and quantum mechanics calculations based on the B3LYP/6-311++G (d,p) are used to analyze different aspects of the solvent effects on the N-15 magnetic shielding constant of pyridine in water. This includes in special the geometry relaxation and the electronic polarization of the solute by the solvent. The polarization effect is found to be very important, but, as expected for pyridine, the geometry relaxation contribution is essentially negligible. Using an average electrostatic model of the solvent, the magnetic shielding constant is calculated as -58.7 ppm, in good agreement with the experimental value of -56.3 ppm. The explicit inclusion of hydrogen-bonded water molecules embedded in the electrostatic field of the remaining solvent molecules gives the value of -61.8 ppm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar o valor da avaliação radiográfica pré-operatória nas revisões de artroplastias totais do joelho. MÉTODOS: Trinta e um joelhos operados no período de 2006 a 2008 em uma série consecutiva de casos de cirurgia de revisão de artroplastia total de joelho foram analisados retrospectivamente. CRITÉRIOS ANALISADOS: número de cunhas ou enxertos ósseos estruturados utilizados para preenchimento dos defeitos ósseos; localização das cunhas e enxertos ósseos utilizados e espessura média do polietileno utilizada. A classificação AORI era estabelecida previamente através de radiografias pré-operatórias segundo critérios preestabelecidos. Após a análise, os joelhos foram divididos em quatro grupos (I, IIA, IIB e III). RESULTADOS: O número médio de cunhas ou enxertos ósseos utilizados em cada joelho variou de maneira crescente entre os grupos (grupo I: 1,33; grupo IIA: 2; grupo IIB: 4,33; grupo III: 4,83) (P = 0,0012). As localizações mais comuns foram: medial na tíbia e posteromedial no fêmur. Não houve diferença estatisticamente significante na espessura do polietileno utilizado. CONCLUSÃO: A classificação AORI para defeitos ósseos no joelho baseada em radiografias pré-operatórias mostrou correlação crescente com a necessidade de utilização de cunhas e/ou enxertos estruturados na revisão de artroplastia total do joelho. Porém, até 46% dos joelhos dos grupos I e IIA apresentaram falhas ósseas de até 5mm não diagnosticadas através das radiografias pré-operatórias.