7 resultados para Physics, Radiation
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This work deals with MEH-PPV thin films to be used as gamma radiation sensors. The polymer thin films with two different thicknesses (30 and 100 nm) were irradiated at room temperature with different gamma radiation doses (up to 25 kGy). Optical properties of the material were investigated with FTIR and UV-Vis absorption spectroscopy. Results show that gamma radiation does not degrade substantially the thin-film material, suggesting that a crosslink effect may be occurring. The characteristic absorption peak of MEH-PPV, around 500 nm is shifted to shorter wavelengths with the increase of gamma radiation doses for both thicknesses samples. The 30-nm-thick samples showed a larger variation absorbance at a specific wavelength and a larger peak shift. These results indicate their potential for use in monitoring the radiation doses used on the sterilization of health care products.
Resumo:
Silver/alanine nanocomposites with varying mass percentage of silver have been produced. The size of the silver nanoparticles seems to drive the formation of the nanocomposite, yielding a homogeneous dispersion of the silver nanoparticles in the alanine matrix or flocs of silver nanoparticles segregated from the alanine crystals. The alanine crystalline orientation is modified according to the particle size of the silver nanoparticles. Concerning a mass percentage of silver below 0.1%, the nanocomposites are homogeneous, and there is no particle aggregation. As the mass percentage of silver is increased, the system becomes unstable, and there is particle flocculation with subsequent segregation of the alanine crystals. The nanocomposites have been analyzed by transmission electron microscopy (TEM), UV-Vis absorption spectroscopy, X-ray diffraction (XRD), and Fourier transform infrared (FTIR) spectroscopy and they have been tested as radiation detectors by means of electron spin resonance (ESR) spectroscopy in order to detect the paramagnetic centers created by the radiation. In fact, the sensitivity of the radiation detectors is optimized in the case of systems containing small particles (30 nm) that are well dispersed in the alanine matrix. As the agglomeration increases, particle growth (up to 1.5 mu m) and segregation diminish the sensitivity. In conclusion, nanostructured materials can be used for optimization of alanine sensitivity, by taking into account the influence of the particles size of the silver nanoparticles on the detection properties of the alanine radiation detectors, thus contributing to the construction of small-sized detectors.
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
Double-stranded pBS plasmid DNA was irradiated with gamma rays at doses ranging from 1 to 12 kGy and electron beams from 1 to 10 kGy. Fragment-size distributions were determined by direct visualization, using atomic force microscopy with nanometer-resolution operating in non-tapping mode, combined with an improved methodology. The fragment distributions from irradiation with gamma rays revealed discrete-like patterns at all doses, suggesting that these patterns are modulated by the base pair composition of the plasmid. Irradiation with electron beams, at very high dose rates, generated continuous distributions of highly shattered DNA fragments, similar to results at much lower dose rates found in the literature. Altogether, these results indicate that AFM could supplement traditional methods for high-resolution measurements of radiation damage to DNA, while providing new and relevant information.
Resumo:
The exact expressions for the characteristics of synchrotron radiation of charged particles in the first excited state are obtained in analytical form using quantum theory methods. We performed a detailed analysis of the angular distribution structure of radiation power and its polarization for particles with spin 0 and 1/2. It is shown that the exact quantum calculations lead to results that differ substantially from the predictions of classical theory.
Resumo:
The aim of this study was to evaluate the gamma radiation effects on odor volatiles in oolong tea at doses of 0, 5, 10, 15 and 20 kGy. The volatile organic compounds were extracted by hydrodistillation and analyzed by GC/MS. The irradiation has a large influence on oolong tea odor profile, once it was identified 40% of new compounds after this process, the 5 kGy and 20 kGy were the doses that degraded more volatiles found naturally in this kind of tea and the dose of 10 kGy was the dose that formed more new compounds. Statistical difference was found between the 5 kGy and 15 kGy volatile profiles, however the sensorial analysis showed that the irradiation at dose up 20 kGy did not interfere on consumer perception. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To evaluate the effectiveness and safety of postoperative low single-dose of beta-irradiation (beta-RT) in pterygium comparing conjunctival autograft (CAG) surgery with CAG plus adjuvant beta-RT in a randomized clinical trial. Methods: This trial was designed as a prospective, randomized, single-center study. Surgery was performed in all cases according to the CAG technique. One hundred and eight pterygia were post-operatively randomized to CAG + beta-RT or CAGalone. In the case of beta-RT, a (90) Sr eye applicator was used to deliver 10 Gy to the sclera surface at a dose rate of between 200 and 250 cGy/min. After treatment, both an ophthalmologist and a radiation oncologist performed the follow-up examinations. The accumulated data were analyzed using a group sequential test. Results: Between February 2008 and September 2008, 116 eyes with primary pterygium were operated on according to the trial protocol. Adjuvant treatment was performed within 24 h post-operatively. Eight patients were lost to follow-up, resulting in 108 patients who could be analyzed. At a mean follow-up of 18 months (range, 8-33), in the 54 eyes randomized to receive CAG + beta-RT, 5 relapses occurred compared with 12 recurrences in the 54 eyes in CAG, for a crude control rate of 90.8 % vs. 78%; p = 0.032, respectively. The treatment complications as hyperemia, total dehiscence of the autograft and dellen were significantly more frequent in the CAG (p < 0.05). The arm of beta-RT resulted in better cosmetic results and improves of symptoms than CAG. Conclusions: A low single-dose of beta-RT of 10 Gy after CAG surgery was a simple, effective, and safe treatment that reduced the risk of primary pterygium recurrence, improved symptoms after surgery, resulting in a better cosmetic effect than only CAG. (C) 2012 Elsevier Inc.