9 resultados para Parametric analysis

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d(15) thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k(15) and piezoelectric stress constant e(15) when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d(15) MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A previous study on the characterization of effective material properties of a d15 thickness-shear piezoelectric Macro-Fibre Composite (MFC) made of seven layers (Kapton, Acrylic, Electrode, Piezoceramic Fibre and Epoxy Composite, Electrode, Acrylic, Kapton) using a finite element homogenization method has shown that the packaging reduces significantly the shear stiffness of the piezoceramic material and, thus, leads to significantly smaller effective electromechanical coupling coefficient k15 and piezoelectric stress constant e15 when compared to the piezoceramic fibre properties. Therefore, the main objective of this work is to perform a parametric analysis in which the effect of the variations of fibre volume fraction, Epoxy elastic modulus, electrode thickness and active layer thickness on the MFC effective material properties is evaluated. Results indicate that an effective d15 MFC should use relatively thick fibres having relatively high shear modulus and relatively stiff epoxy filler. On the other hand, the electrode thickness does not affect significantly the MFC performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The hallmark of Chagas disease (CD) is multifocal myocarditis and extensive fibrosis. We investigated the potential effect of colchicine on myocardial remodeling in experimental CD. Methods and Results: One hundred Syrian hamsters were randomly divided into noninfected untreated control (CG), noninfected control treated with colchicine (COLG 0.4 mg kg(-1) d(-1) by gavage), infected (IG), and infected treated with colchicine (ICOLG, 0.4 mg kg(-1) d(-1)) groups. The interstitial collagen volume fraction (ICVF) was evaluated by videomorphometry with picrosirius red staining. The gelatinolytic activities of matrix metalloproteinase (MMP) 2 were examined with the use of zymography. Myocarditis was described according to the Dallas criteria. Statistical comparisons were performed with parametric analysis of variance and Tukey test. ICVF (%) accumulation was attenuated in infected colchicine-treated animals in the left (CG 0.81 +/- 0.13, COLG 0.85 +/- 0.13, IG: 1.35 +/- 0.31,* ICOLG 1.06 +/- 0.19; *P < .05 compared with ICOLG) and right ventricles (CG 1.4 +/- 0.36, COLG 1.26 +/- 0.14, IG 1.97 +/- 0.058,* ICOLG: 1.52 +/- 0.23; *P < .05 compared with ICOLG). A significant increase in MMP-2 enzymatic activity (UA) was observed in ICOLG (17,432.8*) compared with GC (3731.6), COLG (2,792.6), and IG (4,286.3; *P < .001). In IG, 66% of animals had myocarditis compared with only 49% in ICOLG. Conclusions: Colchicine had a protective effect on myocardium, indicated by decreased interstitial myocardial fibrosis, increased intensity of MMP-2, and attenuated myocardial inflammation. (J Cardiac Fail 2012;18:654-659)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Catenary risers can present during installation a very low tension close to seabed, which combined with torsion moment can lead to a structural instability, resulting in a loop. This is undesirable once it is possible that the loop turns into a kink, creating damage. This work presents a numerical methodology to analyze the conditions of loop formation in catenary risers. Stability criteria were applied to finite element models, including geometric nonlinearities and contact constraint due to riser-seabed interaction. The classical Greenhill's formula was used to predict the phenomenon and parametric analysis shows a “universal plot” able to predict instability in catenaries using a simple equation that can be applied for typical risers installation conditions and, generically, for catenary lines under torsion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Background For analyzing longitudinal familial data we adopted a log-linear form to incorporate heterogeneity in genetic variance components over the time, and additionally a serial correlation term in the genetic effects at different levels of ages. Due to the availability of multiple measures on the same individual, we permitted environmental correlations that may change across time. Results Systolic blood pressure from family members from the first and second cohort was used in the current analysis. Measures of subjects receiving hypertension treatment were set as censored values and they were corrected. An initial check of the variance and covariance functions proposed for analyzing longitudinal familial data, using empirical semi-variogram plots, indicated that the observed trait dispersion pattern follows the assumptions adopted. Conclusion The corrections for censored phenotypes based on ordinary linear models may be an appropriate simple model to correct the data, ensuring that the original variability in the data was retained. In addition, empirical semi-variogram plots are useful for diagnosis of the (co)variance model adopted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The autoregressive (AR) estimator, a non-parametric method, is used to analyze functional magnetic resonance imaging (fMRI) data. The same method has been used, with success, in several other time series data analysis. It uses exclusively the available experimental data points to estimate the most plausible power spectra compatible with the experimental data and there is no need to make any assumption about non-measured points. The time series, obtained from fMRI block paradigm data, is analyzed by the AR method to determine the brain active regions involved in the processing of a given stimulus. This method is considerably more reliable than the fast Fourier transform or the parametric methods. The time series corresponding to each image pixel is analyzed using the AR estimator and the corresponding poles are obtained. The pole distribution gives the shape of power spectra, and the pixels with poles at the stimulation frequency are considered as the active regions. The method was applied in simulated and real data, its superiority is shown by the receiver operating characteristic curves which were obtained using the simulated data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the optimization or parametric analyses of risers, several configurations must be analyzed. It is laborious to perform time domain solutions for the dynamic analysis, since they are time-consuming tasks. So, frequency domain solutions appear to be a possible alternative, mainly in the early stages of a riser design. However, frequency domain analysis is linear and requires that nonlinear effects are treated. The aim of this paper is to present a possible way to treat some of these nonlinearities, using an iterative process together with an analytical correction, and compare the results of a frequency domain analysis with the those of a full nonlinear analysis. [DOI: 10.1115/1.4006149]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of piezoelectric materials for the development of electromechanical devices for the harvesting or scavenging of ambient vibrations has been extensively studied over the last decade. The energy conversion from mechanical (vibratory) to electrical energy is provided by the electromechanical coupling between mechanical strains/stresses and electric charges/voltages in the piezoelectric material. The majority of the studies found in the open literature present a tip-mass cantilever piezoelectric device tuned on the operating frequency. Although recent results show that these devices can be quite effective for harvesting small amounts of electrical energy, little has been published on the robustness of these devices or on the effect of parametric uncertainties on the energy harvested. This work focuses on a cantilever plate with bonded piezoelectric patches and a tip-mass serving as an energy harvesting device. The rectifier and storage electric circuit was replaced by a resistive circuit (R). In addition, an alternative to improve the harvesting performance by adding an inductance in series to the harvesting circuit, thus leading to a resonant circuit (RL), is considered. A coupled finite element model leading to mechanical (displacements) and electrical (charges at electrodes) degrees of freedom is considered. An analysis of the effect of parametric uncertainties of the device on the electric output is performed. Piezoelectric and dielectric constants of the piezoelectric active layers and electric circuit equivalent inductance are considered as stochastic parameters. Mean and confidence intervals of the electric output are evaluated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

—This paper presents a textile patch antenna designed for WBAN applications at 2.45 GHz ISM band. The antenna uses denim as substrate and conductive fabric for the ground plane and radiator layers. The main purpose of this paper is to analyze the influence of typical deviation of denim properties and patch radiator dimensions on the performance of the antenna. The parameters considered in the analysis are the relative permittivity and thickness of denim and the width and length of the rectangular patch radiator. The dependence of the central operation frequency of the antenna on those parameters was studied using the antenna reflection coefficient obtained from EM simulations. Rules of thumb for one-shot design were derived and applied to design a rectangular patch antenna. An antenna prototype was fabricated and measured, demonstrating a 10 dB impedance band of 4.8 % centered at 2.45 GHz, in good agreement with simulated results