2 resultados para Orthodontic anchorage techniques

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to compare the effects of active and passive lacebacks on antero-posterior position of maxillary first molars and central incisors during leveling phase. Twenty-three subjects with Class I and Class II malocclusion were treated with first premolars extraction using preadjusted appliances (MBT 0.022-inch brackets). The leveling phase was performed with stainless steel archwires only. The sample was divided into 2 groups: 14 subjects received active lacebacks (Group 1) and 9 subjects received passive lacebacks (Group 2). Lacebacks were made from 0.008-inch ligature wire. Lateral cephalometric radiographs were taken pre- and post-leveling phase. Student's t-test was applied to determine the differences between pre- and post-leveling mean values and to determine the mean differences between groups. In Group I, the first molars showed a significant mesial movement, whereas no change was observed in Group 2. In both groups, maxillary central incisor crowns moved to lingual side. In conclusion, active laceback produced anchorage loss of maxillary first molars whereas passive laceback did not affect the position of these teeth. Active and passive lacebacks were effective in preventing central incisor proclination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To verify if mini-implant mobility is affected by the presence of periodontopathogens, frequently associated with peri-implantitis. Materials and Methods: The surfaces of 31 mini-implants used for skeletal anchorage in orthodontic patients were evaluated. Polymerase chain reaction was used for identification of the presence of DNA from three different periodontopathogens (P. intermedia [Pi], A. actinomycetemcomitans [Aa], and P. gingivalis [Pg]) in 16 mini-implants without mobility (control group) and 15 mini-implants with mobility (experimental group). Results: The results showed that Pi was present in 100% of the samples, from both groups: Aa was found in 31.3% of the control group and in 13.3% of the experimental group. Pg was detected in 37.4% of the control group and in 33.3% of the experimental group. The Fisher exact test and the odds ratio (OR) values for Aa and Pg (OR = 0.34; 95% confidence interval [CI]: 0.05-2.10 and OR = 0.61; 95% Cl: 0.13-2.79, respectively) showed no significant association (P > .05) between the periodontopathogens studied and the mobility of the mini-implants. Conclusions: It can be concluded that the presence of Aa, Pi, and Pg around mini-implants is not associated with mobility. (Angle Orthod. 2012;82:591-595.)