3 resultados para Occupational field
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objective: To evaluate whether there are visual and neurophysical decrements in workers with low exposure to Hg vapor. Methods: Visual fields, contrast sensitivity, color vision, and neuropsychological functions were measured in 10 workers (32.5 +/- 8.5 years) chronically exposed to Hg vapor (4.3 +/- 2.8 years; urinary Hg concentration 22.3 +/- 9.3 mu g/g creatinine). Results: For the worst eyes, we found altered visual field thresholds, lower contrast sensitivity, and color discrimination compared with controls (P < 0.05). There were no significant differences between Hg-exposed subjects and controls on. neuropsychological tests. Nevertheless, duration of exposure was statistically correlated to verbal memory and depression scores. Conclusions: Chronic exposure to Hg vapor at currently accepted safety levels was found to be associated with visual losses but not with neuropsychological dysfunctions in the sample of workers studied. (J Occup Environ Med. 2009,51:1403-1412)
Resumo:
Visual field losses associated with mercury (Hg) exposure have only been assessed in patients exposed to methylmercury. Here we evaluate the automated visual field in 35 ex-workers (30 males; 44.20+/-5.92 years) occupationaly exposed to mercury vapor and 34 controls (21 males; 43.29+/-8.33 years). Visual fields were analyzed with the Humphrey Field Analyzer II (model 750i) using two tests: the standard automated perimetry (SAP, white-on-white) and the short wavelength automated perimetry (SWAP, blue-on-yellow) at 76 locations within a 27 degrees central visual field. Results were analyzed as the mean of the sensitivities measured at the fovea, and at five successive concentric rings, of increasing eccentricity, within the central field. Compared to controls, visual field sensitivities of the experimental group measured using SAP were lower for the fovea as well as for all five eccentricity rings (p<0.05). Sensitivities were significantly lower in the SWAP test (p<0.05) for four of the five extra-foveal eccentricity rings; they were not significant for the fovea (p = 0.584) or for the 15 degrees eccentricity ring (p = 0.965). These results suggest a widespread reduction of sensitivity in both visual field tests. Previous reports in the literature describe moderate to severe concentric constriction of the visual field in subjects with methylmercury intoxication measured manually with the Goldman perimeter. The present results amplify concerns regarding potential medical risks of exposure to environmental mercury sources by demonstrating significant and widespread reductions of visual sensitivity using the more reliable automated perimetry. (C) 2007 Elsevier Inc. All rights reserved.
Resumo:
The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.