10 resultados para Objective Image Quality
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objectives: The objective of this study is to compare subjective image quality and diagnostic validity of cone-beam CT (CBCT) panoramic reformatting with digital panoramic radiographs. Materials and methods: Four dry human skulls and two formalin-fixed human heads were scanned using nine different CBCTs, one multi-slice CT (MSCT) and one standard digital panoramic device. Panoramic views were generated from CBCTs in four slice thicknesses. Seven observers scored image quality and visibility of 14 anatomical structures. Four observers repeated the observation after 4 weeks. Results: Digital panoramic radiographs showed significantly better visualization of anatomical structures except for the condyle. Statistical analysis of image quality showed that the 3D imaging modalities (CBCTs and MSCT) were 7.3 times more likely to receive poor scores than the 2D modality. Yet, image quality from NewTom VGi® and 3D Accuitomo 170® was almost equivalent to that of digital panoramic radiographs with respective odds ratio estimates of 1.2 and 1.6 at 95% Wald confidence limits. A substantial overall agreement amongst observers was found. Intra-observer agreement was moderate to substantial. Conclusions: While 2D-panoramic images are significantly better for subjective diagnosis, 2/3 of the 3D-reformatted panoramic images are moderate or good for diagnostic purposes. Clinical relevance: Panoramic reformattings from particular CBCTs are comparable to digital panoramic images concerning the overall image quality and visualization of anatomical structures. This clinically implies that a 3D-derived panoramic view can be generated for diagnosis with a recommended 20-mm slice thickness, if CBCT data is a priori available for other purposes.
Resumo:
OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.
Resumo:
Background: Few data on the definition of simple robust parameters to predict image noise in cardiac computed tomography (CT) exist. Objectives: To evaluate the value of a simple measure of subcutaneous tissue as a predictor of image noise in cardiac CT. Methods: 86 patients underwent prospective ECG-gated coronary computed tomographic angiography (CTA) and coronary calcium scoring (CAC) with 120 kV and 150 mA. The image quality was objectively measured by the image noise in the aorta in the cardiac CTA, and low noise was defined as noise < 30HU. The chest anteroposterior diameter and lateral width, the image noise in the aorta and the skin-sternum (SS) thickness were measured as predictors of cardiac CTA noise. The association of the predictors and image noise was performed by using Pearson correlation. Results: The mean radiation dose was 3.5 ± 1.5 mSv. The mean image noise in CT was 36.3 ± 8.5 HU, and the mean image noise in non-contrast scan was 17.7 ± 4.4 HU. All predictors were independently associated with cardiac CTA noise. The best predictors were SS thickness, with a correlation of 0.70 (p < 0.001), and noise in the non-contrast images, with a correlation of 0.73 (p < 0.001). When evaluating the ability to predict low image noise, the areas under the ROC curve for the non-contrast noise and for the SS thickness were 0.837 and 0.864, respectively. Conclusion: Both SS thickness and CAC noise are simple accurate predictors of cardiac CTA image noise. Those parameters can be incorporated in standard CT protocols to adequately adjust radiation exposure.
Resumo:
FUNDAMENTO: A redução da frequência cardíaca (FC) na angiografia por tomografia das artérias coronarianas (ATCCor) é fundamental para a qualidade de imagem. A eficácia dos bloqueadores de cálcio como alternativas para pacientes com contraindicações aos betabloqueadores não foi definida. OBJETIVOS: Comparar a eficácia na redução da FC e variabilidade RR do metoprolol e diltiazem na ATCCor. MÉTODOS: Estudo prospectivo, randomizado, aberto, incluiu pacientes com indicação clínica de ATCCor, em ritmo sinusal, com FC>70bpm e sem uso de agentes que interferissem com a FC. Cinquenta pacientes foram randomizados para grupos: metoprolol IV 5-15 mg ou até FC≤60 bpm(M), e diltiazem IV 0,25-0,60mg/kg ou até FC≤60 bpm (D). Pressão arterial (PA) e FC foram aferidas na condição basal, 1min, 3min e 5min após agentes, na aquisição e após ATCCor. RESULTADOS: A redução da FC em valores absolutos foi maior no grupo M que no grupo D (1, 3, 5min, aquisição e pós-exame). A redução percentual da FC foi significativamente maior no grupo M apenas no 1 min e 3 min após início dos agentes. Não houve diferença no 5 min, durante a aquisição e após exame. A variabilidade RR percentual do grupo D foi estatisticamente menor do que a do grupo M durante a aquisição (variabilidade RR/ FC média da aquisição). Um único caso de BAV, 2:1 Mobitz I, revertido espontaneamente ocorreu (grupo D). CONCLUSÃO: Concluímos que o diltiazem é uma alternativa eficaz e segura aos betabloqueadores na redução da FC na realização de angiografia por tomografia computadorizada das artérias coronarianas. (Arq Bras Cardiol. 2012; [online].ahead print, PP.0-0)
Resumo:
In this work, a Monte Carlo code was used to investigate the performance of different x-ray spectra in digital mammography, through a figure of merit (FOM), defined as FOM = CNR2/(D) over bar (g), with CNR being the contrast-to-noise ratio in image and (D) over bar (g) being the average glandular dose. The FOM was studied for breasts with different thicknesses t (2 cm <= t <= 8 cm) and glandular contents (25%, 50% and 75% glandularity). The anode/filter combinations evaluated were those traditionally employed in mammography (Mo/Mo, Mo/Rh, Rh/Rh), and a W anode combined with Al or K-edge filters (Zr, Mo, Rh, Pd, Ag, Cd, Sn), for tube potentials between 22 and 34 kVp. Results show that the W anode combined with K-edge filters provides higher values of FOM for all breast thicknesses investigated. Nevertheless, the most suitable filter and tube potential depend on the breast thickness, and for t >= 6 cm, they also depend on breast glandularity. Particularly for thick and dense breasts, a W anode combined with K-edge filters can greatly improve the digital technique, with the values of FOM up to 200% greater than that obtained with the anode/filter combinations and tube potentials traditionally employed in mammography. For breasts with t < 4 cm, a general good performance was obtained with the W anode combined with 60 mu m of the Mo filter at 24-25 kVp, while 60 mu m of the Pd filter provided a general good performance at 24-26 kVp for t = 4 cm, and at 28-30 and 29-31 kVp for t = 6 and 8 cm, respectively.
Resumo:
Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.
Resumo:
Context. The ESO public survey VISTA variables in the Via Lactea (VVV) started in 2010. VVV targets 562 sq. deg in the Galactic bulge and an adjacent plane region and is expected to run for about five years. Aims. We describe the progress of the survey observations in the first observing season, the observing strategy, and quality of the data obtained. Methods. The observations are carried out on the 4-m VISTA telescope in the ZYJHK(s) filters. In addition to the multi-band imaging the variability monitoring campaign in the K-s filter has started. Data reduction is carried out using the pipeline at the Cambridge Astronomical Survey Unit. The photometric and astrometric calibration is performed via the numerous 2MASS sources observed in each pointing. Results. The first data release contains the aperture photometry and astrometric catalogues for 348 individual pointings in the ZYJHK(s) filters taken in the 2010 observing season. The typical image quality is similar to 0 ''.9-1 ''.0. The stringent photometric and image quality requirements of the survey are satisfied in 100% of the JHK(s) images in the disk area and 90% of the JHK(s) images in the bulge area. The completeness in the Z and Y images is 84% in the disk, and 40% in the bulge. The first season catalogues contain 1.28 x 10(8) stellar sources in the bulge and 1.68 x 10(8) in the disk area detected in at least one of the photometric bands. The combined, multi-band catalogues contain more than 1.63 x 10(8) stellar sources. About 10% of these are double detections because of overlapping adjacent pointings. These overlapping multiple detections are used to characterise the quality of the data. The images in the JHK(s) bands extend typically similar to 4 mag deeper than 2MASS. The magnitude limit and photometric quality depend strongly on crowding in the inner Galactic regions. The astrometry for K-s = 15-18 mag has rms similar to 35-175 mas. Conclusions. The VVV Survey data products offer a unique dataset to map the stellar populations in the Galactic bulge and the adjacent plane and provide an exciting new tool for the study of the structure, content, and star-formation history of our Galaxy, as well as for investigations of the newly discovered star clusters, star-forming regions in the disk, high proper motion stars, asteroids, planetary nebulae, and other interesting objects.
Resumo:
This study aimed to evaluate the sleep quality and impact of thoracentesis on sleep in patients with a large pleural effusion. Patients with large unilateral pleural effusion were evaluated by the Pittsburgh Sleep Quality Index (PSQI) questionnaire and dyspnea Borg scale. Full polysomnography (PSG) was performed on the night before and 36 h after thoracentesis. We studied 19 patients, 11 males and 8 females, age 55 +/- 18 years and body mass index of 26 +/- 5 kg/m(2). The baseline sleep quality was poor (PSQI = 9.1 +/- 3.5). Thoracentesis removed 1.624 +/- 796 mL of pleural fluid and resulted in a significant decrease in dyspnea Borg scale (2.3 +/- 2.1 vs. 0.8 +/- 0.9, p < 0.001). The PSG before and after thoracentesis showed no significant change in apnea-hypopnea index and sleep time with oxygen saturation < 90%. There was a significant improvement in sleep efficiency (76% vs. 81%, p = 0.006), decrease percent sleep stage 1 (16% vs. 14%, p = 0.002), and a trend improvement in total sleep time (344 +/- 92 vs. 380 +/- 69 min, p = 0.056) and percentage of rapid eye movement sleep (15% vs. 20%, p = 0.053). No significant changes occurred in six patients that performed two consecutive PSG before thoracentesis. The improvement in sleep quality was not associated with the volume of pleural fluid withdrawn or changes in dyspnea. Patients with large pleural effusion have poor subjective and objective sleep quality that improves after thoracentesis.
Resumo:
There is a wide range of telecommunications services that transmit voice, video and data through complex transmission networks and in some cases, the service has not an acceptable quality level for the end user. In this sense the study of methods for assessing video quality and voice have a very important role. This paper presents a classification scheme, based on different criteria, of the methods and metrics that are being studied in recent years. This paper presents how the video quality is affected by degradation in the transmission channel in two kinds of services: Digital TV (ISDB-TB) due the fading in the air interface and video streaming service on an IP network due packet loss. For Digital TV tests was set up a scenario where the digital TV transmitter is connected to an RF channel emulator, where are inserted different fading models and at the end, the videos are saved in a mobile device. The tests of streaming video were performed in an isolated scenario of IP network, which are scheduled several network conditions, resulting in different qualities of video reception. The video quality assessment is performed using objective assessment methods: PSNR, SSIM and VQM. The results show how the losses in the transmission channel affects the quality of end-user experience on both services studied.
Resumo:
The objective of this work were apply and provide a preliminary evaluation of the Weather Research and Forecasting model coupled with Chemistry (WRF-Chem) performance, for Londrina region. We performed comparison with measurements obtained in meteorological stations. The model was configured to run with three domains with 27,9 and 3 km of grid resolution, using the ndown program and also was realized a simulation with the model configured to run with a single domain using a land use file based in a classified image for region of MODIS sensor. The emission files to supply the chemistry run were generated based in the work of Martins et al., 2012. RADM2 chemical mechanism and MADE/SORGAM modal aerosol models were used in the simulations. The results demonstrated that model was able to represent coherently the formation and dispersion of the pollution in Metropolitan Region of Londrina and also the importance of using the appropriate land use file for the region.