6 resultados para National standards

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To assess the setting time (ST), flow (FL), radiopacity (RD), solubility (SB) and dimensional change following setting (DC) of different sealers (AH Plus (R), Polifil, Apexit Plus (R), Sealapex (R), Endomethasone (R) and Endofill (R)) according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. Material and methods: Five samples of each material were used for each test. For ST, cast rings were filled with sealers and tested with a Gillmore needle. For FL, the sealer was placed on a glass plate. After 180 s, another plate with 20 g and a load of 100 g were applied on the material, and the diameters of the discs formed were measured. In RD, circular molds were filled with the sealers, radiographed and analyzed using Digora software. For SB, circular molds were filled with the sealers, a nylon thread was placed inside the material and another glass plate was positioned on the set, pressed and stored at 37 degrees C. Samples were weighed, placed in water, dried and reweighed. The water used for SB was analyzed by atomic absorption spectrometry. For DC, circular molds were filled with the sealers, covered by glass plates and stored at 37 degrees C. Samples were measured and stored in water for 30 days. After this period, they were dryed and measured again. Results: Regarding ST, AH Plus (R), Apexit (R) and Endofil (R) sealers are in accordance with ANSI/ADA standards. Endomethasone's manufacturer did not mention the ST; Polifil is an experimental sealer and Sealapex (R) did not set. Considering RD, SB and DC, all sealers were in accordance with ANSI/ADA. The spectrometric analysis showed that a significant amount of K+ and Zn2(+) ions was released from Apexit Plus (R) and Endofill (R), respectively. Conclusion: Except for DC, all other physicochemical properties of the tested sealers conformed to ANSI/ADA requirements.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the pH, calcium ion release, setting time, and solubility of white mineral trioxide aggregate (WMTA) and white Portland cement (WPC) combined with the following radiopacifying agents: bismuth oxide (BO), calcium tungstate (CT), and zirconium oxide (ZO). Methods: Fifty acrylic teeth with root-end filling material were immersed in ultrapure water for measurement of pH and calcium release (atomic absorption spectrophotometry) at 3, 24, 72, and 168 hours. For evaluation of setting time, each material was analyzed according to the American Society for Testing and Materials guidelines 266/08. The solubility test was performed according to American National Standards Institute/American Dental Association specification no. 57/2000. Solubility, setting time, and pH values were compared by using analysis of variance and Tukey test, and the values of calcium release were compared by the Kruskal-Wallis and Miller tests. The significance level was set at 5%. Results: The pH and calcium release were higher at 3 and 24 hours. WPC was the material with the higher values for both properties. WMTA had the greatest solubility among all materials (P < .05). All radiopacifiers increased the setting time of WPC, and WMTA had the shortest setting time among all materials (P < .05). Conclusions: All materials released calcium ions. Except for WPC/CT at 168 hours, all materials promoted an alkaline pH. On the basis of the obtained results, ZO and CT can be considered as potential radiopacifying agents to be used in combination with Portland cement. (J Endod 2012;38:394-397)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Baldi JV, Bernardes RA, Duarte MAH, Ordinola-Zapata R, Cavenago BC, Moraes JCS, de Moraes IG. Variability of physicochemical properties of an epoxy resin sealer taken from different parts of the same tube. International Endodontic Journal,similar to 45, 915920, 2012. Abstract Aim To analyse several physicochemical properties of AH Plus (Dentsply DeTrey, Konstanz, Germany), including setting time, flow, radiopacity and the degree of conversion (DC); and to correlate the results with the source of the material: from the beginning, middle or end of the tubes in which they were supplied. Methodology Three experimental groups were established for each property investigated. Group 1 corresponded to material taken from the beginning of tubes A and B; Group 2 corresponded to material taken from the middle of each tube; and group 3 corresponded to that from the end of each tube. The setting time, flow and radiopacity were studied according to American National Standards Institute/American Dental Association (ANSI/ADA) Specification 57. DC was determined from infrared spectra, which were recorded at 1-h intervals for the first 6 h; then, at 2-h intervals for the next 14 h; then, at 24 and 30 h. Data were analysed statistically by analysis of variance (anova), TukeyKramer, KruskalWallis and Dunn tests, with a significance level of 5%. Results Group 1 had a significantly longer setting time (2303 +/- 1058 min) (P < 0.05). Group 3 had the lowest flowability (30.0 +/- 0.7 mm) and the highest radiopacity (14.85 +/- 1.8 mm Al) (P < 0.05). No differences were found for the DC test (P > 0.05). Conclusion The results suggest that segregation occurs between the organic and inorganic components of AH Plus sealer, thereby changing the setting time, flow and radiopacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The huge transformations that occurred in the last two decades had impacts on the standards of food production and consumption, and determined a wider discussion in Brazil about the theme of food and nutrition security. It has also expanded the scope of it, which now considers nourishing aspects regarding the entire population and not only its most vulnerable segments. This research identified different meanings present in the speech about food and nutrition security, terms incorporated by movements and civil society organizations that were represented at the National Council for Food and Nutrition Security (administration 2004-2007). Thematic appropriation could be observed in the following directions: a) privileging the interaction between thematic fields from both production and consumption spheres; b) strengthening the idea of nutrition as a human right; c) including an ethical goal to the country's development; d) development of an intra and intersectorial perspective; e) identifying the need of dialogic and freeing educational processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared in vitro dissolution characteristics and other quality measures of different amoxicillin, metronidazole, and zidovudine products purchased in the Americas to a comparator pharmaceutical product (CPP). These three drugs are classified as Biopharmaceutics Classification System Class I drugs with the possibility that dissolution findings might be used to document bioequivalence. All investigated zidovudine products were found to be in vitro equivalent to the CPP. Only 3 of 12 tested amoxicillin products were found to be in vitro equivalent to the CPP. None of the tested metronidazole products were in vitro equivalent to the CPP. These findings suggest but do not confirm bioinequivalence where in vitro comparisons failed, given that an in vivo blood level study might have confirmed bioequivalence. At times, identifying a CPP in one of the selected markets proved difficult. The study demonstrates that products sold across national markets may not be bioequivalent. When coupled with the challenge of identifying a CPP in different countries, the results of this study suggest the value of an international CPP as well as increased use of BCS approaches as means of either documenting bioequivalence or signaling the need for further in vivo studies. Because of increased movement of medicines across national borders, practitioners and patients would benefit from these approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discussions on the future of cataloging has received increased attention in the last ten years, mainly due to the impact of rapid development of information and communication technologies in the same period, which has provided access to the Web anytime, anywhere. These discussions revolve around the need for a new bibliographic framework to meet the demand of this new reality in the digital environment, ie how libraries can process, store, deliver, share and integrate their collections (physical, digital or scanned), in current post-PC era? Faced with this question, Open Access, Open Source and Open Standards are three concepts that need to receive greater attention in the field of Library and Information Science, as it is believed to be fundamental elements for the change of paradigm of descriptive representation, currently based conceptually on physical item rather than intellectual work. This paper aims to raise and discuss such issues and instigate information professionals, especially librarians, to think, discuss and propose initiatives for such problems, contributing and sharing ideas and possible solutions, in multidisciplinary teams. At the end is suggested the effective creation of multidisciplinary and inter-institutional study groups on the future of cataloging and its impact on national collections, in order to contribute to the area of descriptive representation in national and international level