9 resultados para Multiplicação dos Pães
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
We aimed to develop site-specific sediment quality guidelines (SQGs) for two estuarine and port zones in Southeastern Brazil (Santos Estuarine System and Paranagua Estuarine System) and three in Southern Spain (Ria of Huelva, Bay of Cadiz, and Bay of Algeciras), and compare these values against national and traditionally used international benchmark values. Site-specific SQGs were derived based on sediment physical-chemical, toxicological, and benthic community data integrated through multivariate analysis. This technique allowed the identification of chemicals of concern and the establishment of effects range correlatively to individual concentrations of contaminants for each site of study. The results revealed that sediments from Santos channel, as well as inner portions of the SES, are considered highly polluted (exceeding SQGs-high) by metals, PAHs and PCBs. High pollution by PAHs and some metals was found in Sao Vicente channel. In PES, sediments from inner portions (proximities of the Ponta do Mix port`s terminal and the Port of Paranagua) are highly polluted by metals and PAHs, including one zone inside the limits of an environmental protection area. In Gulf of Cadiz, SQGs exceedences were found in Ria of Huelva (all analysed metals and PAHs), in the surroundings of the Port of CAdiz (Bay of CAdiz) (metals), and in Bay of Algeciras (Ni and PAHs). The site-specific SQGs derived in this study are more restricted than national SQGs applied in Brazil and Spain, as well as international guidelines. This finding confirms the importance of the development of site-specific SQGs to support the characterisation of sediments and dredged material. The use of the same methodology to derive SQGs in Brazilian and Spanish port zones confirmed the applicability of this technique with an international scope and provided a harmonised methodology for site-specific SQGs derivation. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Sediment quality from Paranagua Estuarine System (PES), a highly important port and ecological zone, was evaluated by assessing three lines of evidence: (1) sediment physical-chemical characteristics; (2) sediment toxicity (elutriates, sediment-water interface, and whole sediment); and (3) benthic community structure. Results revealed a gradient of increasing degradation of sediments (i.e. higher concentrations of trace metals, higher toxicity, and impoverishment of benthic community structure) towards inner PES. Data integration by principal component analysis (PCA) showed positive correlation between some contaminants (mainly As, Cr, Ni, and Pb) and toxicity in samples collected from stations located in upper estuary and one station placed away from contamination sources. Benthic community structure seems to be affected by both pollution and natural fine characteristics of the sediments, which reinforces the importance of a weight-of-evidence approach to evaluate sediments of PES. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
Nebulized l-epinephrine has been recommended for the treatment of viral croup. However, the few studies assessing its effect on post-extubation stridor (PES) have shown conflicting results. We compared the efficacy and safety of nebulized l-epinephrine at three different doses for the treatment of PES. We conducted a prospective, randomized, double-blind trial including all consecutive children with a PES score of a parts per thousand yen4 (Westley score). The primary efficacy outcome was change in PES score at 40 min. A reduction of a parts per thousand yen2 points in stridor score was defined as clinically significant. A total of 96 patients were randomly assigned to receive one of three doses of nebulized l-epinephrine upon achieving a PES score of 4 or more following extubation. Stridor score and vital signs were recorded before treatment, and at 20, 40, 60 and 180 min after nebulization. Baseline characteristics were similar among all study groups. No significant difference was detected among the treatments based on change in Westley score by intent-to-treat analysis. In addition, the difference in the number of patients who clinically improved among the treatment groups was not significant (p = 0.54). Patients receiving 5 ml nebulized epinephrine had a significant increase of systolic and diastolic blood pressure at 40 and 180 min. Nebulized l-epinephrine at doses of 0.5, 2.5 and 5 ml demonstrated a lack of dose response in effect on PES and a modestly clinically significant increase in undesired side effects (heart rate and blood pressure) at higher doses.
Resumo:
The interference of some specific aqueous two-phase system (ATPS) phase-forming components in bovine serum albumin (BSA) determination by the Bradford method was investigated. For this purpose, calibration curves were obtained for BSA in the presence of different concentrations of salts and polymers. A total of 19 salts [Na2SO4, (NH4)(2)SO4, MgSO4, LiSO4, Na2HPO4, sodium phosphate buffer (pH 7.0), NaH2PO4, K2HPO4, potassium phosphate buffer (pH 7.0), KH2PO4, C6H8O7, Na3C6HSO7, KCHO2, NaCHO2, NaCO3, NaHCO3, C2H4O2, sodium acetate buffer (pH 4.5), and NaC2H3O2] and 7 polymers [PEG 4000, PEG 8000, PEG 20000, UCON 3900, Ficoll 70000, PES 100000, and PVP 40000] were tested, and each calibration curve was compared with the one obtained for BSA in water. Some concentrations of salts and polymers had considerable effect in the BSA calibration curve. Carbonate salts were responsible for the highest salt interference, whereas citric and acetic acids did not produce interference even in the maximum concentration level tested (5 wt%). Among the polymers, UCON gave the highest interference, whereas Ficoll did not produce interference when used in concentrations up to 10 wt%. It was concluded that a convenient dilution of the samples prior to the protein quantification is needed to ensure no significant interference from ATPS phase-forming constituents. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
Polymer electrolytes (PEs) are currently the focus of much attention as potential electrolytes in electrochemical devices such as batteries, display devices and sensors. Deoxyribonucleic acid (DNA) as an important biological macromolecule has electric conducting electrochemical properties and unique three dimensional structures. With the goal of developing a new family of environmentally friendly multifunctional biohybrid materials displaying simultaneously high ionic conductivity we have produced in the present work, flexible films based on DNA, incorporating ionic liquids (ILs). Over the last decade ILs have been employed as a new media in electrochemistry and electroanalysis. The materials studied here have been characterized by means of Differential Scanning Calorimetry, Complex Impedance Spectroscopy and Cyclic Voltammetry. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
As emas são aves ratitas nativas do continente sul americano, são consideradas aves primitivas do ponto de vista filogenético que constituem um grupo altamente especializado. Este estudo buscou caracterizar macro e microscopicamente o fígado e pâncreas de emas. O material foi coletado no Centro de Multiplicação de Animais Silvestres (CEMAS), na cidade de Mossoró-RN, Brasil, (Registro IBAMA n° 14.78912). Utilizaram-se 20 animais jovens com idade entre dois e seis meses independente do sexo. Em emas, o fígado se relacionava cranialmente com o ápice do coração, dorsalmente com os pulmões, esôfago e o proventrículo gástrico, caudalmente, com o ventrículo gástrico, o baço, o duodeno e parte do jejuno. Apresentava coloração vermelha escura e possuía apenas dois lobos, sendo o direito ligeiramente menor que o esquerdo. Histologicamente, era revestido por uma cápsula de tecido conjuntivo delgada e cada lóbulo hepático pôde ser identificado pela presença evidente de veias centrais, com muitos sinusoides comunicando-se com elas. O pâncreas, ventralmente, apresentava-se como uma fita fina, formado por um lobo dorsal e um lobo ventral. Longitudinalmente o pâncreas em emas localiza-se no mesentério dorsal desde o fígado até a flexura cranial do duodeno, mantendo-se preso às alças duodenais por ligamentos. Histologicamente, era composto por uma cápsula delgada de tecido conjuntivo denso, com discretos lóbulos separados por tecido conjuntivo capsular, compostos por estruturas tubuloalveolares e ductos. O fígado e pâncreas de emas apresentam padrão morfológico similar ao descrito para aves domésticas.
Resumo:
Gellan-based polymer electrolytes (PEs), doped with lithium iodide (LiI), were prepared and their electrical properties were characterized. The samples are thermally stable up to 234 degrees C and exhibit ionic conductivity of 3.8 x 10(-4) S/cm at room temperature for the sample doped with 40 wt% of LiI. Addition of 10 wt% of glycerol promotes an increase of the ionic conductivity to 1.5 x 10(-3) S/cm, which remains stable up to 100 degrees C. The activation energies of 2.4 to 12.4 kJ/mol were derived from the Arrhenius model. The repeated ionic conductivity measurements as a function of temperature show that these membranes can be reversibly used between the room temperature and 100 degrees C.
Resumo:
A multiplicação de experiências participativas visando ampliar o controle social sobre políticas e políticos tornou-se fenômeno relevante no Brasil e mundo afora. Neste artigo é apresentado um quadro analítico útil à comparação da diversidade da inovação democrática enquanto arquitetura da participação orientada para o controle social. Mediante a aplicação desse quadro, examinamos a configuração de duas arquiteturas contrastantes, originárias de dois contextos nacionais distintos: México e Brasil.
Resumo:
This paper presents the results of research aiming to develop partial discharge detection techniques in high voltage equipment, at substation environment. Measurements of high frequency components of leakage current, at equipments' grounding conductor, were performed. This procedure was performed with the equipment energized and without disconnecting it from the system. The partial discharge generated current pulse is picked up by a high frequency CT, and is detected by an oscilloscope. The partial discharge identification was made considering previously obtained laboratory results, where partial discharges were characterized by means of its time domain signatures. This paper focuses measurements in SF6 circuit breakers. Encouraging results were obtained, showing the feasibility of detecting partial discharges in energized equipment in the laboratory and in the field, in a substation environment, using this method.