4 resultados para Mobile mammography

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Breast cancer is the most frequently diagnosed cancer and the leading cause of cancer deaths among women worldwide. The use of mobile mammography units to offer screening to women living in remote areas is a rational strategy to increase the number of women examined. This study aimed to evaluate results from the first 2 years of a government-organized mammography screening program implemented with a mobile unit (MU) and a fixed unit (FU) in a rural county in Brazil. The program offered breast cancer screening to women living in Barretos and the surrounding area. Methods: Based on epidemiologic data, 54 238 women, aged 40 to 69 years, were eligible for breast cancer screening. The study included women examined from April 1, 2003 to March 31, 2005. The chi-square test and Bonferroni correction analyses were used to evaluate the frequencies of tumors and the importance of clinical parameters and tumor characteristics. Significance was set at p < 0.05. Results: Overall, 17 964 women underwent mammography. This represented 33.1% of eligible women in the area. A mean of 18.6 and 26.3 women per day were examined in the FU and MU, respectively. Seventy six patients were diagnosed with breast cancer (41 (54%) in the MU). This represented 4.2 cases of breast cancer per 1000 examinations. The number of cancers detected was significantly higher in women aged 60 to 69 years than in those aged 50 to 59 years (p < 0.001) or 40 to 49 years (p < 0.001). No difference was observed between women aged 40 to 49 years and those aged 50 to 59 years (p = 0.164). The proportion of tumors in the early (EC 0 and EC I) and advanced (CS III and CS IV) stages of development were 43.4% and 15.8%, respectively. Conclusions: Preliminary results indicate that this mammography screening program is feasible for implementation in a rural Brazilian territory and favor program continuation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a Monte Carlo code was used to investigate the performance of different x-ray spectra in digital mammography, through a figure of merit (FOM), defined as FOM = CNR2/(D) over bar (g), with CNR being the contrast-to-noise ratio in image and (D) over bar (g) being the average glandular dose. The FOM was studied for breasts with different thicknesses t (2 cm <= t <= 8 cm) and glandular contents (25%, 50% and 75% glandularity). The anode/filter combinations evaluated were those traditionally employed in mammography (Mo/Mo, Mo/Rh, Rh/Rh), and a W anode combined with Al or K-edge filters (Zr, Mo, Rh, Pd, Ag, Cd, Sn), for tube potentials between 22 and 34 kVp. Results show that the W anode combined with K-edge filters provides higher values of FOM for all breast thicknesses investigated. Nevertheless, the most suitable filter and tube potential depend on the breast thickness, and for t >= 6 cm, they also depend on breast glandularity. Particularly for thick and dense breasts, a W anode combined with K-edge filters can greatly improve the digital technique, with the values of FOM up to 200% greater than that obtained with the anode/filter combinations and tube potentials traditionally employed in mammography. For breasts with t < 4 cm, a general good performance was obtained with the W anode combined with 60 mu m of the Mo filter at 24-25 kVp, while 60 mu m of the Pd filter provided a general good performance at 24-26 kVp for t = 4 cm, and at 28-30 and 29-31 kVp for t = 6 and 8 cm, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Background The public health system of Brazil is structured by a network of increasing complexity, but the low resolution of emergency care at pre-hospital units and the lack of organization of patient flow overloaded the hospitals, mainly the ones of higher complexity. The knowledge of this phenomenon induced Ribeirão Preto to implement the Medical Regulation Office and the Mobile Emergency Attendance System. The objective of this study was to analyze the impact of these services on the gravity profile of non-traumatic afflictions in a University Hospital. Methods The study conducted a retrospective analysis of the medical records of 906 patients older than 13 years of age who entered the Emergency Care Unit of the Hospital of the University of São Paulo School of Medicine at Ribeirão Preto. All presented acute non-traumatic afflictions and were admitted to the Internal Medicine, Surgery or Neurology Departments during two study periods: May 1996 (prior to) and May 2001 (after the implementation of the Medical Regulation Office and Mobile Emergency Attendance System). Demographics and mortality risk levels calculated by Acute Physiology and Chronic Health Evaluation II (APACHE II) were determined. Results From 1996 to 2001, the mean age increased from 49 ± 0.9 to 52 ± 0.9 (P = 0.021), as did the percentage of co-morbidities, from 66.6 to 77.0 (P = 0.0001), the number of in-hospital complications from 260 to 284 (P = 0.0001), the mean calculated APACHE II mortality risk increased from 12.0 ± 0.5 to 14.8 ± 0.6 (P = 0.0008) and mortality rate from 6.1 to 12.2 (P = 0.002). The differences were more significant for patients admitted to the Internal Medicine Department. Conclusion The implementation of the Medical Regulation and Mobile Emergency Attendance System contributed to directing patients with higher gravity scores to the Emergency Care Unit, demonstrating the potential of these services for hierarchical structuring of pre-hospital networks and referrals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a logic-based formalism for qualitative spatial reasoning with cast shadows (Perceptual Qualitative Relations on Shadows, or PQRS) and presents results of a mobile robot qualitative self-localisation experiment using this formalism. Shadow detection was accomplished by mapping the images from the robot’s monocular colour camera into a HSV colour space and then thresholding on the V dimension. We present results of selflocalisation using two methods for obtaining the threshold automatically: in one method the images are segmented according to their grey-scale histograms, in the other, the threshold is set according to a prediction about the robot’s location, based upon a qualitative spatial reasoning theory about shadows. This theory-driven threshold search and the qualitative self-localisation procedure are the main contributions of the present research. To the best of our knowledge this is the first work that uses qualitative spatial representations both to perform robot self-localisation and to calibrate a robot’s interpretation of its perceptual input.