10 resultados para Method of extraction
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Seaweeds are photosynthetic organisms important to their ecosystem and constitute a source of compounds with several different applications in the pharmaceutical, cosmetic and biotechnology industries, such as triacylglycerols, which can be converted to fatty acid methyl esters that make up biodiesel, an alternative source of fuel applied in economic important areas. This study evaluates the fatty acid profiles and concentrations of three Brazilian seaweed species, Hypnea musciformis (Wulfen) J.V. Lamouroux (Rhodophya), Sargassum cymosum C. Agardh (Heterokontophyta), and Ulva lactuca L. (Chlorophyta), comparing three extraction methods (Bligh & Dyer - B&D; AOAC Official Methods - AOM; and extraction with methanol and ultrasound - EMU) and two transesterification methods (7% BF3 in methanol - BF3; and 5% HCl in methanol - HCl). The fatty acid contents of the three species of seaweeds were significantly different when extracted and transesterified by the different methods. Moreover, the best method for one species was not the same for the other species. The best extraction and transesterification methods for H. musciformis, S. cymosum and U. lactuca were, respectively, AOM-HCl, B&D-BF3 and B&D-BF3/B&D-HCl. These results point to a matrix effect and the method used for the analysis of the fatty acid content of different organisms should be selected carefully.
Resumo:
Combining data from multiple analytical platforms is essential for comprehensive study of the molecular phenotype (metabotype) of a given biological sample. The metabolite profiles generated are intrinsically dependent on the analytical platforms, each requiring optimization of instrumental parameters, separation conditions, and sample extraction to deliver maximal biological information. An in-depth evaluation of extraction protocols for characterizing the metabolome of the hepatobiliary fluke Fasciola hepatica, using ultra performance liquid chromatography and capillary electrophoresis coupled with mass spectroscopy is presented. The spectrometric methods were characterized by performance, and metrics of merit were established, including precision, mass accuracy, selectivity, sensitivity, and platform stability. Although a core group of molecules was common to all methods, each platform contributed a unique set, whereby 142 metabolites out of 14,724 features were identified. A mixture design revealed that the chloroform:methanol:water proportion of 15:59:26 was globally the best composition for metabolite extraction across UPLC-MS and CE-MS platforms accommodating different columns and ionization modes. Despite the general assumption of the necessity of platform-adapted protocols for achieving effective metabotype characterization, we show that an appropriately designed single extraction procedure is able to fit the requirements of all technologies. This may constitute a paradigm shift in developing efficient protocols for high-throughput metabolite profiling with more-general analytical applicability.
Resumo:
This new and general method here called overflow current switching allows a fast, continuous, and smooth transition between scales in wide-range current measurement systems, like electrometers. This is achieved, using a hydraulic analogy, by diverting only the overflow current, such that no slow element is forced to change its state during the switching. As a result, this approach practically eliminates the long dead time in low-current (picoamperes) switching. Similar to a logarithmic scale, a composition of n adjacent linear scales, like a segmented ruler, measures the current. The use of a linear wide-range system based on this technique assures fast and continuous measurement in the entire range, without blind regions during transitions and still holding suitable accuracy for many applications. A full mathematical development of the method is given. Several computer realistic simulations demonstrated the viability of the technique.
Resumo:
Purpose: Dynamic near infrared fluorescence imaging of the urinary tract provides a promising way to diagnose ureteropelvic junction obstruction. Initial studies demonstrated the ability to visualize urine flow and peristalsis in great detail. We analyzed the efficacy of near infrared imaging in evaluating ureteropelvic junction obstruction, renal involvement and the anatomical detail provided compared to conventional imaging modalities. Materials and Methods: Ten swine underwent partial or complete unilateral ureteral obstruction. Groups were survived for the short or the long term. Imaging was performed with mercaptoacetyltriglycine diuretic renogram, magnetic resonance urogram, excretory urogram, ultrasound and near infrared imaging. Scoring systems for ureteropelvic junction obstruction were developed for magnetic resonance urogram and near infrared imaging. Physicians and medical students graded ureteropelvic junction obstruction based on magnetic resonance urogram and near infrared imaging results. Results: Markers of vascular and urinary dynamics were quantitatively consistent among control renal units. The same markers were abnormal in obstructed renal units with significantly different times of renal phase peak, start of pelvic phase and start of renal uptake. Such parameters were consistent with those obtained with mercaptoacetyltriglycine diuretic renography. Near infrared imaging provided live imaging of urinary flow, which was helpful in identifying the area of obstruction for surgical planning. Physicians and medical students categorized the degree of obstruction appropriately for fluorescence imaging and magnetic resonance urogram. Conclusions: Near infrared imaging offers a feasible way to obtain live, dynamic images of urine flow and ureteral peristalsis. Qualitative and quantitative parameters were comparable to those of conventional imaging. Findings support fluorescence imaging as an accurate, easy to use method of diagnosing ureteropelvic junction obstruction.
Resumo:
Computed tomography (CT)-guided percutaneous drilling is an alternative for osteoid osteoma treatment. This study aims to evaluate the remodeling of the drill orifice. The success rate and complications were also recorded and compared with other treatment methods.
Resumo:
The objective of this study was to investigate the possibility of using hydric restriction as a method for evaluating vigor of soybean seeds. The soybean seeds, cultivar BRS 245RR, represented by four different seed lots, were characterized by germination and vigor. For the treatment of hydric restriction and temperature, the combination of substrate water potential and temperature were the following: deionized water (0.0 MPa); polyethylene glycol (PEG 6000) aqueous solution (-0.1, -0.3 and -0.5 MPa); and four temperatures (20 ºC, 25 ºC, 30 ºC, and 35 ºC), respectively. A completely randomized experimental design was used, with four replications per treatment, and the ANOVA was performed individually for each combination of temperature and water potential of substrate. According to results obtained, the test of hydric restriction has the same efficiency of the accelerated aging test in estimating vigor of soybean seeds, cv. BRS 245RR, when water potentials of -0.1 MPa or -0.3 MPa at a temperature of 25 ºC, or -0.3 MPa at a temperature of 30 ºC are used.
Resumo:
Landfarm soils are employed in industrial and petrochemical residue bioremediation. This process induces selective pressure directed towards microorganisms capable of degrading toxic compounds. Detailed description of taxa in these environments is difficult due to a lack of knowledge of culture conditions required for unknown microorganisms. A metagenomic approach permits identification of organisms without the need for culture. However, a DNA extraction step is first required, which can bias taxonomic representativeness and interfere with cloning steps by extracting interference substances. We developed a simplified DNA extraction procedure coupled with metagenomic DNA amplification in an effort to overcome these limitations. The amplified sequences were used to generate a metagenomic data set and the taxonomic and functional representativeness were evaluated in comparison with a data set built with DNA extracted by conventional methods. The simplified and optimized method of RAPD to access metagenomic information provides better representativeness of the taxonomical and metabolic aspects of the environmental samples.
Resumo:
The present work describes for the first time the use of SPME coupled to LC-MS/MS employing the polar organic mode in a stereoselective fungal biotransformation study to investigate the fungi ability to biotransform the drug risperidone into its chiral and active metabolite 9-hydroxyrisperidone (9-RispOH). The chromatographic separation was performed on a Chiralcel OJ-H column using methanol:ethanol (50:50, v/v) plus 0.2% triethylamine as the mobile phase at a flow rate of 0.8 mL min(-1). The SPME process was performed using a C18 fiber, 30 min of extraction time and 5 min of desorption time in the mobile phase. The method was completely validated and all parameters were in agreement with the literature recommendations. The Cunninghamella echinulata fungus was able to biotransform risperidone into the active metabolite, (+)-9-RispOH, resulting in 100% of enantiomeric excess. The Cunninghamella elegans fungus was also able to stereoselectively biotransform risperidone into (+)- and (-)-9-RispOH enantiomers at different rates. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Objective: To evaluate the degree of perception of laypersons, dental professionals, and dental students regarding dental esthetics in cases with mandibular central incisor extraction. Materials and Methods: Using a smile photograph of a person with normal occlusion and all teeth, modifications were made to reflect the extraction of a mandibular incisor of various compositions and sizes. For this purpose a program specifically for image manipulation (Adobe Photoshop CS3, Adobe Systems Inc) was used. After manipulation the images were printed on photographic paper, attached to a questionnaire and distributed to laypersons, dental professionals, and dental students (n = 90) to evaluate the degree of perception and esthetic using a scale of attractiveness, where 0 = hardly attractive, 5 = attractive, and 10 = very attractive. The differences between examiners were checked by the Mann-Whitney test. All the statistics were performed with a confidence level of 95%. Results: The results demonstrated the skill of the dental professionals and dental students in perceiving the difference between cases of normal occlusion and cases where an incisor was lacking (P < .05). The photograph in which the lateral incisors were shown to be larger than the central incisor was the one that obtained the highest value among the cases of extraction in all groups of evaluators. Conclusions: It can be concluded that dental professionals and dental students are more skillful at identifying deviation from normality. In addition, central incisor extraction should always be discarded when there are other treatment options available. (Angle Orthod. 2012;82:732-738.)
Resumo:
Most studies on measures of transpiration of plants, especially woody fruit, relies on methods of heat supply in the trunk. This study aimed to calibrate the Thermal Dissipation Probe Method (TDP) to estimate the transpiration, study the effects of natural thermal gradients and determine the relation between outside diameter and area of xylem in 'Valencia' orange young plants. TDP were installed in 40 orange plants of 15 months old, planted in boxes of 500 L, in a greenhouse. It was tested the correction of the natural thermal differences (DTN) for the estimation based on two unheated probes. The area of the conductive section was related to the outside diameter of the stem by means of polynomial regression. The equation for estimation of sap flow was calibrated having as standard lysimeter measures of a representative plant. The angular coefficient of the equation for estimating sap flow was adjusted by minimizing the absolute deviation between the sap flow and daily transpiration measured by lysimeter. Based on these results, it was concluded that the method of TDP, adjusting the original calibration and correction of the DTN, was effective in transpiration assessment.