20 resultados para Metal sensitivity test

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. Methods: Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injection. Patients were submitted to a complete evaluation including best corrected visual acuity, contrast sensitivity and optical coherence tomography measurements before treatment and one and three months after injection. Visual acuity, contrast sensitivity and optical coherence tomography measurements were compared to baseline values. Results: Mean visual acuity measurement improved from 0.77 logMAR at baseline to 0.613 logMAR one month after injection (P=0.0001) but worsened to 0.75 logMAR after three months. Contrast sensitivity test demonstrated significant improvement at spatial frequencies of 3, 6, 12 and 18 cycles/degree one month after injection and at the spatial frequency of 12 cycles/degree three months after treatment. Mean +/- standard deviation baseline central macular thickness (552 +/- 150 mu m) reduced significantly one month (322 +/- 127 mu m, P=0.0001) and three months (439 perpendicular to 179 mu m, P=0.01) after treatment. Conclusions: Bevacizumab injection improves visual acuity and contrast sensitivity and reduces central macular thickness one month after treatment. Visual acuity returns to baseline levels at the 3-month follow-up, but some beneficial effect of the treatment is still present at that time, as evidenced by optical coherence tomography-measured central macular thickness and contrast sensitivity measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Color vision impairment emerges at early stages of diabetes mellitus type 2 (DM2) and may precede diabetic retinopathy or the appearance of vascular alterations in the retina. The aim of the present study was to compare the evaluation of the color vision with two different tests - the Lanthony desaturated D-15d test (a traditional color arrangement test), and the Cambridge Colour Test (CCT) (a computerized color discrimination test) - in patients diagnosed with DM2 without clinical signs of diabetic retinopathy (DR), and in sex- and age-matched control groups. Both color tests revealed statistically significant differences between the controls and the worst eyes of the DM2 patients. In addition, the degree of color vision impairment diagnosed by both tests correlated with the disease duration. The D-15d outcomes indicated solely tritan losses. In comparison, CCT outcomes revealed diffuse losses in color discrimination: 13.3% for best eyes and 29% for worst eyes. In addition, elevation of tritan thresholds in the DM2 patients, as detected by the Trivector subtest of the CCT, was found to correlate with the level of glycated hemoglobin. Outcomes of both tests confirm that subclinical losses of color vision are present in DM2 patients at an early stage of the disease, prior to signs of retinopathy. Considering the advantages of the CCT test compared to the D-15d test, further studies should attempt to verify and/or improve the efficiency of the CCT test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study aimed at providing conditions for the assessment of color discrimination in children using a modified version of the Cambridge Colour Test (CCT, Cambridge Research Systems Ltd., Rochester, UK). Since the task of indicating the gap of the Landolt C used in that test proved counterintuitive and/or difficult for young children to understand, we changed the target Stimulus to a patch of color approximately the size of the Landolt C gap (about 7 degrees Of Visual angle at 50 cm from the monitor). The modifications were performed for the CCT Trivector test which measures color discrimination for the protan, deutan and tritan confusion lines. Experiment I Sought to evaluate the correspondence between the CCT and the child-friendly adaptation with adult subjects (n = 29) with normal color vision. Results showed good agreement between the two test versions. Experiment 2 tested the child-friendly software with children 2 to 7 years old (n = 25) using operant training techniques for establishing and maintaining the subjects` performance. Color discrimination thresholds were progressively lower as age increased within the age range tested (2 to 30 years old), and the data-including those obtained for children-fell within the range of thresholds previously obtained for adults with the CCT. The protan and deutan thresholds were consistently lower than tritan thresholds, a pattern repeatedly observed in adults tested with the CCT. The results demonstrate that the test is fit for assessment of color discrimination in young children and may be a useful tool for the establishment of color vision thresholds during development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We assessed chromatic discrimination in multiple sclerosis (MS) patients both with (ON) and without (no ON) a history of optic neuritis using the Cambridge color test (CCT). Our goal was to determine the magnitude and chromatic axes of any color vision losses in both patient groups, and to evaluate age-related changes in chromatic discrimination in both patient groups compared to normals. Using the CCT, we measured chromatic discrimination along the protan, deutan and tritan axes in 35 patients with MS (17 ON eyes) and 74 age matched controls. Color thresholds for both patient groups were significantly higher than controls` along the protan and tritan axes (P < 0.001). In addition, the ON and no-ON groups differed significantly along all three-color axes (p < 0.001). MS patients presented a progressive color discrimination impairment with age (along the deutan and tritan axes) that was almost two times faster than controls, even in the absence of ON. These findings suggest that demyelinating diseases reduce sensitivity to color vision in both red-green and blue-yellow axes, implying impairment in both parvocellular and koniocellular visual pathways. The CCT is a useful tool to help characterize vision losses in MS and the relationship between these losses and degree of optic nerve involvement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. Material and Methods: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey's multiple comparison test (p<0.05). Results: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. Conclusions: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Obtaining ecotoxicological data on pesticides in tropical regions is imperative for performing more realistic risk analysis, and avoidance tests have been proposed as a useful, fast and cost-effective tool. Therefore, the present study aimed to evaluate the avoidance behavior of Eisenia andrei to a formulated product, Vertimec(A (R)) 18 EC (a.i abamectin), in tests performed on a reference tropical artificial soil (TAS), to derive ecotoxicological data on tropical conditions, and a natural soil (NS), simulating crop field conditions. In TAS tests an adaptation of the substrate recommended by OECD and ISO protocols was used, with residues of coconut fiber as a source of organic matter. Concentrations of the pesticide on TAS test ranged from 0 to 7 mg abamectin/kg (dry weight-d.w.). In NS tests, earthworms were exposed to samples of soils sprayed in situ with: 0.9 L of Vertimec(A (R)) 18 EC/ha (RD); twice as much this dosage (2RD); and distilled water (Control), respectively, and to 2RD: control dilutions (12.5, 25, 50, 75%). All tests were performed under 25 +/- A 2A degrees C, to simulate tropical conditions, and a 12hL:12hD photoperiod. The organisms avoided contaminated TAS for an EC50,48h = 3.918 mg/kg soil d.w., LOEC = 1.75 mg/kg soil d.w. and NOEC = 0.85 mg/kg soil d.w. No significant avoidance response occurred for any NS test. Abamectin concentrations in NS were rather lower than EC50, 48h and LOEC determined in TAS tests. The results obtained contribute to overcome a lack of ecotoxicological data on pesticides under tropical conditions, but more tests with different soil invertebrates are needed to improve pesticides risk analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High saturated and trans fatty acid intake, the typical dietary pattern of Western populations, favors a proinflammatory status that contributes to generating insulin resistance (IR). We examined whether the consumption of these fatty acids was associated with IR and inflammatory markers. In this cross-sectional study, 127 non-diabetic individuals were allocated to a group without IR and 56 to another with IR, defined as homeostasis model assessment-IR (HOMA-IR) >2.71. Diet was assessed using 24-h food recalls. Multiple linear regression was employed to test independent associations with HOMA-IR. The IR group presented worse anthropometric, biochemical and inflammatory profiles. Energy intake was correlated with abdominal circumference and inversely with adiponectin concentrations (r = -0.227, P = 0.002), while saturated fat intake correlated with inflammatory markers and trans fat with HOMA-IR (r = 0.160, P = 0.030). Abdominal circumference was associated with HOMA-IR (r = 0.430, P < 0.001). In multiple analysis, HOMA-IR remained associated with trans fat intake (beta = 1.416, P = 0.039) and body mass index (beta = 0.390, P < 0.001), and was also inversely associated with adiponectin (beta = -1.637, P = 0.004). Inclusion of other nutrients (saturated fat and added sugar) or other inflammatory markers (IL-6 and CRP) into the models did not modify these associations. Our study supports that trans fat intake impairs insulin sensitivity. The hypothesis that its effect could depend on transcription factors, resulting in expression of proinflammatory genes, was not corroborated. We speculate that trans fat interferes predominantly with insulin signaling via intracellular kinases, which alter insulin receptor substrates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the tensile strength, elongation, microhardness, microstructure and fracture pattern of various metal ceramic alloys cast under different casting conditions. Two Ni-Cr alloys, Co-Cr and Pd-Ag were used. The casting conditions were as follows: electromagnetic induction under argon atmosphere, vacuum, using blowtorch without atmosphere control. For each condition, 16 specimens, each measuring 25 mm long and 2.5 mm in diameter, were obtained. Ultimate tensile strength (UTS) and elongation (EL) tests were performed using a Kratos machine. Vickers Microhardness (VM), fracture mode and microstructure were analyzed by SEM. UTS, EL and VM data were statistically analyzed using ANOVA. For UTS, alloy composition had a direct influence on casting condition of alloys (Wiron 99 and Remanium CD), with higher values shown when cast with Flame/Air (p < 0.05). The factors "alloy" and "casting condition" influenced the EL and VM results, generally presenting opposite results, i.e., alloy with high elongation value had lower hardness (Wiron 99), and casting condition with the lowest EL values had the highest VM values (blowtorch). Both factors had significant influence on the properties evaluated, and prosthetic laboratories should select the appropriate casting method for each alloy composition to obtain the desired property.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To determine the accuracy of the Timed Up and Go Test (TUGT) for screening the risk of falls among community-dwelling elderly individuals. Method: This is a prospective cohort study with a randomly by lots without reposition sample stratified by proportional partition in relation to gender involving 63 community-dwelling elderly individuals. Elderly individuals who reported having Parkinson's disease, a history of transitory ischemic attack, stroke and with a Mini Mental State Exam lower than the expected for the education level, were on a wheelchair and that reported a single fall in the previous six months were excluded. The TUGT, a mobility test, was the measure of interested and the occurrence of falls was the outcome. The performance of basic activities of daily living (ADL) and instrumental activities of daily living (IADL) was determined through the Older American Resources and Services, and the socio-demographic and clinical data were determined through the use of additional questionnaires. Receiver Operating Characteristic Curves were used to analyze the sensitivity and specificity of the TUGT. Results: Elderly individuals who fell had greater difficulties in ADL and IADL (p<0.01) and a slower performance on the TUGT (p=0.02). No differences were found in socio-demographic and clinical characteristics between fallers and non- fallers. Considering the different sensitivity and specificity, the best predictive value for discriminating elderly individuals who fell was 12.47 seconds [(RR= 3.2) 95% CI: 1.3- 7.7]. Conclusions: The TUGT proved to be an accurate measure for screening the risk of falls among elderly individuals. Although different from that reported in the international literature, the 12.47 second cutoff point seems to be a better predictive value for Brazilian elderly individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We deal with the optimization of the production of branched sheet metal products. New forming techniques for sheet metal give rise to a wide variety of possible profiles and possible ways of production. In particular, we show how the problem of producing a given profile geometry can be modeled as a discrete optimization problem. We provide a theoretical analysis of the model in order to improve its solution time. In this context we give the complete convex hull description of some substructures of the underlying polyhedron. Moreover, we introduce a new class of facet-defining inequalities that represent connectivity constraints for the profile and show how these inequalities can be separated in polynomial time. Finally, we present numerical results for various test instances, both real-world and academic examples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and aims: Although studies have shown association of birth weight (BW) and adult body mass index (BMI) with insulin sensitivity in adults, there is limited evidence that BW is associated with insulin secretion. We assessed the associations between BW and current BMI with insulin sensitivity and secretion in young Latin American adults. Methods and results: Two birth cohorts, one from Ribeirao Preto, Brazil, based on 1984 participants aged 23-25 years, and another from Limache, Chile, based on 965 participants aged 22-28 years were studied. Weight and height at birth, and current fasting plasma glucose and insulin levels were measured. Insulin sensitivity (HOMA%S) and secretion (HOMA%beta) were estimated using the Homeostatic Model Assessment (HOMA2). Multiple linear regression analyses were carried out to test the associations between BW and adult BMI z-scores on log HOMA%S and log HOMA%beta. BW z-score was associated with HOMA%S in the two populations and HOMA%beta in Ribeirao Preto when adult BMI z-score was included in the model. BW z-score was associated with decreasing insulin secretion even without adjusting for adult BMI, but only in Ribeirao Preto. BMI z-score was associated with low HOMA%S and high HOMA%beta. No interactions between BW and BMI z-scores on insulin sensitivity were shown. Conclusions: This study supports the finding that BW may affect insulin sensitivity and secretion in young adults. The effect size of BW on insulin status is small in comparison to current BMI. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We sought to evaluate the performance of diagnostic tools to establish an affordable setting for early detection of cervical cancer in developing countries. We compared the performance of different screening tests and their feasibility in a cohort of over 12,000 women: conventional Pap smear, liquid-based cytology, visual inspection with acetic acid (VIA), visual inspection with Iodine solution (VILI), cervicography, screening colposcopy, and high-risk human papillomavirus (HPV) testing (HR-HPV) collected by physician and by self-sampling. HR-HPV assay collected by the physician has the highest sensitivity (80 %), but high unnecessary referrals to colposcopy (15.1 %). HR-HPV test in self-sampling had a markedly lower (57.1 %) sensitivity. VIA, VILI, and cervicography had a poor sensitivity (47.4, 55, and 28.6 %, respectively). Colposcopy presented with sensitivity of 100 % in detecting CIN2+, but the lowest specificity (66.9 %). Co-testing with VIA and VILI Pap test increased the sensitivity of stand-alone Pap test from 71.6 to 87.1 % and 71.6 to 95 %, respectively, but with high number of unnecessary colposcopies. Co-testing with HR-HPV importantly increased the sensitivity of Pap test (to 86 %), but with high number of unnecessary colposcopies (17.5 %). Molecular tests adjunct to Pap test seems a realistic option to improve the detection of high-grade lesions in population-based screening programs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background In areas with limited structure in place for microscopy diagnosis, rapid diagnostic tests (RDT) have been demonstrated to be effective. Method The cost-effectiveness of the Optimal® and thick smear microscopy was estimated and compared. Data were collected on remote areas of 12 municipalities in the Brazilian Amazon. Data sources included the National Malaria Control Programme of the Ministry of Health, the National Healthcare System reimbursement table, hospitalization records, primary data collected from the municipalities, and scientific literature. The perspective was that of the Brazilian public health system, the analytical horizon was from the start of fever until the diagnostic results provided to patient and the temporal reference was that of year 2006. The results were expressed in costs per adequately diagnosed cases in 2006 U.S. dollars. Sensitivity analysis was performed considering key model parameters. Results In the case base scenario, considering 92% and 95% sensitivity for thick smear microscopy to Plasmodium falciparum and Plasmodium vivax, respectively, and 100% specificity for both species, thick smear microscopy is more costly and more effective, with an incremental cost estimated at US$549.9 per adequately diagnosed case. In sensitivity analysis, when sensitivity and specificity of microscopy for P. vivax were 0.90 and 0.98, respectively, and when its sensitivity for P. falciparum was 0.83, the RDT was more cost-effective than microscopy. Conclusion Microscopy is more cost-effective than OptiMal® in these remote areas if high accuracy of microscopy is maintained in the field. Decision regarding use of rapid tests for diagnosis of malaria in these areas depends on current microscopy accuracy in the field.