9 resultados para Magnetic response

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Understanding how magnetic materials respond to rapidly varying magnetic fields, as in dynamic hysteresis loops, constitutes a complex and physically interesting problem. But in order to accomplish a thorough investigation, one must necessarily consider the effects of thermal fluctuations. Albeit being present in all real systems, these are seldom included in numerical studies. The notable exceptions are the Ising systems, which have been extensively studied in the past, but describe only one of the many mechanisms of magnetization reversal known to occur. In this paper we employ the Stochastic Landau-Lifshitz formalism to study high-frequency hysteresis loops of single-domain particles with uniaxial anisotropy at an arbitrary temperature. We show that in certain conditions the magnetic response may become predominantly out-of-phase and the loops may undergo a dynamic symmetry loss. This is found to be a direct consequence of the competing responses due to the thermal fluctuations and the gyroscopic motion of the magnetization. We have also found the magnetic behavior to be exceedingly sensitive to temperature variations, not only within the superparamagnetic-ferromagnetic transition range usually considered, but specially at even lower temperatures, where the bulk of interesting phenomena is seen to take place. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Considerable effort has been made in recent years to optimize materials properties for magnetic hyperthermia applications. However, due to the complexity of the problem, several aspects pertaining to the combined influence of the different parameters involved still remain unclear. In this paper, we discuss in detail the role of the magnetic anisotropy on the specific absorption rate of cobalt-ferrite nanoparticles with diameters ranging from 3 to 14 nm. The structural characterization was carried out using x-ray diffraction and Rietveld analysis and all relevant magnetic parameters were extracted from vibrating sample magnetometry. Hyperthermia investigations were performed at 500 kHz with a sinusoidal magnetic field amplitude of up to 68 Oe. The specific absorption rate was investigated as a function of the coercive field, saturation magnetization, particle size, and magnetic anisotropy. The experimental results were also compared with theoretical predictions from the linear response theory and dynamic hysteresis simulations, where exceptional agreement was found in both cases. Our results show that the specific absorption rate has a narrow and pronounced maxima for intermediate anisotropy values. This not only highlights the importance of this parameter but also shows that in order to obtain optimum efficiency in hyperthermia applications, it is necessary to carefully tailor the materials properties during the synthesis process. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4729271]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Repetitive transcranial magnetic stimulation (rTMS) has been widely tested and shown to be effective for unipolar depression. Although it has also been investigated for bipolar depression (BD), there are only few rTMS studies with BD. Here, we investigated 56 patients with BD who received rTMS treatment until remission (defined as Hamilton Depression Rating Scores <= 7). We used simple and multiple logistic regressions to identify clinical and demographic predictors associated with duration of treatment (defined as <15 vs. >15 rTMS sessions). Age, refractoriness, number of prior depressive episodes, and severe depression at baseline were associated with a longer rTMS treatment. In the multivariate analysis, refractoriness (likelihood ratio (LR) = 4.33; p < 0.01) and baseline severity (LR = 0.18, p < 0.01) remained significant predictors. Our preliminary study showed that, in remitted patients, refractoriness and severity of index episode are associated with the need of a longer rTMS treatment; providing preliminary evidence of important factors associated with rTMS parameters adjustment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We find the first nonlinear correction to the field produced by a static charge at rest in a background constant magnetic field. It is quadratic in the charge and purely magnetic. The third-rank polarization tensor-the nonlinear response function-is written within the local approximation of the effective action in an otherwise model-and approximation-independent way within any P-invariant nonlinear electrodynamics, QED included. DOI: 10.1103/PhysRevD.86.125028

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The success of magnetic hyperthermia cancer treatments rely strongly on the magnetic properties of the nanoparticles and their intricate dependence on the externally applied field. This is particularly more so as the response departs from the low field linear regime. In this paper we introduce a new parameter, referred to as the efficiency in converting electromagnetic energy into thermal energy, which is shown to be remarkably useful in the analysis of the system response, especially when the power loss is investigated as a function of the applied field amplitude. Using numerical simulations of dynamic hysteresis, through the stochastic Landau-Lifshitz model, we map in detail the efficiency as a function of all relevant parameters of the system and compare the results with simple-yet powerful-predictions based on heuristic arguments about the relaxation time. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4705392]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The photoluminescence from individual quantum wells of artificially disordered weakly coupled multi-layers embedded in wide AlGaAs parabolic wells was investigated in a strong magnetic field. We show that the response of the individual wells is very different from the average response of the multi-layers studied by transport measurements and that photoluminescence represents a local probe of the quantum Hall state formed in three-dimensional electron system. The observed magnetic field induced variations of the in-layer electron density demonstrate the formation of a new phase in the quasi-three-dimensional electron system. The sudden change in the local electron density found at the Landau filling factor nu = 1 by both the magneto-transport and the magneto-photoluminescence measurements was assigned to the quantum phase transition. Copyright (C) EPLA, 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pulmonary arterial hypertension (PAH) is a disease of the pulmonary vasculature characterized by vasoconstriction and vascular remodeling leading to a progressive increase in pulmonary vascular resistance (PVR). It is becoming increasingly recognized that it is the response of the right ventricle (RV) to the increased afterload resulting from this increase in PVR that is the most important determinant of patient outcome. A range of hemodynamic, structural, and functional measures associated with the RV have been found to have prognostic importance in PAH and, therefore, have potential value as parameters for the evaluation and follow-up of patients. If such measures are to be used clinically, there is a need for simple, reproducible, accurate, easy-to-use, and noninvasive methods to assess them. Cardiac magnetic resonance imaging (CMRI) is regarded as the "gold standard" method for assessment of the RV, the complex structure of which makes accurate assessment by 2-dimensional methods, such as echocardiography, challenging. However, the majority of data concerning the use of CMRI in PAH have come from studies evaluating a variety of different measures and using different techniques and protocols, and there is a clear need for the development of standardized methodology if CMRI is to be established in the routine assessment of patients with PAH. Should such standards be developed, it seems likely that CMRI will become an important method for the noninvasive assessment and monitoring of patients with PAH. (C) 2012 Elsevier Inc. All rights reserved. (Am J Cardiol 2012;110[suppl]:25S-31S)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Enhanced sodium intake increases volume overload, oxidative stress and production of proinflammatory cytokines. In animal models, increased sodium intake favours ventricular dysfunction after myocardial infarction (MI). The aim of this study was to investigate, in human subjects presenting with ST-segment elevation MI (STEMI), the impact of sodium intake prior the coronary event. Methods: Consecutive patients (n = 372) admitted within the first 24 h of STEMI were classified by a food intake questionnaire as having a chronic daily intake of sodium higher (HS) or lower (LS) than 1.2 g in the last 90 days before MI. Plasma levels of 8-isoprostane, interleucin-2 (IL-2), tumour necrosis factor type alpha (TNF-alpha), C-reactive protein (CRP) and brain natriuretic peptide (BNP) were measured at admission and at the fifth day. Magnetic resonance imaging was performed immediately after discharge. Total mortality and recurrence of acute coronary events were investigated over 4 years of follow-up. Results: The decrease of 8-isoprostane was more prominent and the increase of IL-2, TNF-alpha and CRP less intense during the first 5 days in LS than in HS patients (p < 0.05). Sodium intake correlated with change in plasma BNP between admission and fifth day (r = 0.46; p < 0.0001). End-diastolic volumes of left atrium and left ventricle were greater in HS than in LS patients (p < 0.05). In the first 30 days after MI and up to 4 years afterwards, total mortality was higher in HS than in LS patients (p < 0.05). Conclusion: Excessive sodium intake increases oxidative stress, inflammatory response, myocardial stretching and dilatation, and short and long-term mortality after STEMI. (C) 2012 Elsevier Ireland Ltd. All rights reserved.