3 resultados para Maghetti, Benedetto

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Breast cancer metastasis is a leading cause of death by malignancy in women worldwide. Efforts are being made to further characterize the rate-limiting steps of cancer metastasis, i.e. extravasation of circulating tumor cells and colonization of secondary organs. In this study, we investigated whether angiotensin II, a major vasoactive peptide both produced locally and released in the bloodstream, may trigger activating signals that contribute to cancer cell extravasation and metastasis. We used an experimental in vivo model of cancer metastasis in which bioluminescent breast tumor cells (D3H2LN) were injected intra-cardiacally into nude mice in order to recapitulate the late and essential steps of metastatic dissemination. Real-time intravital imaging studies revealed that angiotensin II accelerates the formation of metastatic foci at secondary sites. Pre-treatment of cancer cells with the peptide increases the number of mice with metastases, as well as the number and size of metastases per mouse. In vitro, angiotensin II contributes to each sequential step of cancer metastasis by promoting cancer cell adhesion to endothelial cells, trans-endothelial migration and tumor cell migration across extracellular matrix. At the molecular level, a total of 102 genes differentially expressed following angiotensin II pretreatment were identified by comparative DNA microarray. Angiotensin II regulates two groups of connected genes related to its precursor angiotensinogen. Among those, up-regulated MMP2/MMP9 and ICAM1 stand at the crossroad of a network of genes involved in cell adhesion, migration and invasion. Our data suggest that targeting angiotensin II production or action may represent a valuable therapeutic option to prevent metastatic progression of invasive breast tumors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of dental plaque and moisture on performance of a laser fluorescence device in detecting occlusal and proximal caries lesions in primary teeth. Fifty-five occlusal and 58 proximal sites on primary molars were evaluated using a DIAGNOdent pen (LFpen) device. For the drying time study, the evaluations were performed in: (I) moist teeth; (II) teeth dried for 3 s, or (III) dried for 15 s. For the plaque study, the evaluations were done in sites: (I) without plaque; (II) with plaque, and (III) after cleaning. Evaluation of the teeth sections in stereomicroscope was the reference standard method. LF pen values, sensitivity, specificity, and accuracy were compared. The values obtained after 15 s of drying were higher than those obtained with moist teeth or dried for 3 s at both occlusal and proximal surfaces. However, there was no change in the performance in detecting caries lesions. With regard to the presence of plaque, there was no significant change in the readings of the device, but specificity was decreased in occlusal surfaces with plaque. At proximal surfaces, however, no significant differences were observed. In conclusion, the moisture conditions do not influence significantly the performance of the LFpen, but the presence of plaque can affect its performance in detecting occlusal caries lesions in primary teeth.