6 resultados para Lower limit
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
As a part of the AMAZE-08 campaign during the wet season in the rainforest of central Amazonia, an ultraviolet aerodynamic particle sizer (UV-APS) was operated for continuous measurements of fluorescent biological aerosol particles (FBAP). In the coarse particle size range (> 1 mu m) the campaign median and quartiles of FBAP number and mass concentration were 7.3x10(4) m(-3) (4.0-13.2x10(4) m(-3)) and 0.72 mu g m(-3) (0.42-1.19 mu g m(-3)), respectively, accounting for 24% (11-41%) of total particle number and 47% (25-65%) of total particle mass. During the five-week campaign in February-March 2008 the concentration of coarse-mode Saharan dust particles was highly variable. In contrast, FBAP concentrations remained fairly constant over the course of weeks and had a consistent daily pattern, peaking several hours before sunrise, suggesting observed FBAP was dominated by nocturnal spore emission. This conclusion was supported by the consistent FBAP number size distribution peaking at 2.3 mu m, also attributed to fungal spores and mixed biological particles by scanning electron microscopy (SEM), light microscopy and biochemical staining. A second primary biological aerosol particle (PBAP) mode between 0.5 and 1.0 mu m was also observed by SEM, but exhibited little fluorescence and no true fungal staining. This mode may have consisted of single bacterial cells, brochosomes, various fragments of biological material, and small Chromalveolata (Chromista) spores. Particles liquid-coated with mixed organic-inorganic material constituted a large fraction of observations, and these coatings contained salts likely from primary biological origin. We provide key support for the suggestion that real-time laser-induce fluorescence (LIF) techniques using 355 nm excitation provide size-resolved concentrations of FBAP as a lower limit for the atmospheric abundance of biological particles in a pristine environment. We also show some limitations of using the instrument for ambient monitoring of weakly fluorescent particles < 2 mu m. Our measurements confirm that primary biological particles, fungal spores in particular, are an important fraction of supermicron aerosol in the Amazon and that may contribute significantly to hydrological cycling, especially when coated by mixed inorganic material.
Resumo:
In the present work we revisit the size data of CdS microcrystals previously collected in the glassy matrix of Germanium oxide. The CdS clusters analyzed using electron microscopy images have shown a wurtzite structure. The mean average radius, dispersion and volume evaluated from the histograms showed good agreement for t(1/3), t(2/3) and t laws, respectively. We observed that the amount of microcrystals remains constant throughout the heat treatment process, as well as that the radii distribution has a lower limit and increases with heat treatment. The distribution of radii follows a distribution similar to the Lifshitz-Slyozov-Wagner distribution limited in the origin. Discussions led to the conclusion that the growth of CdS is a process that occurs after the fluctuating nucleation and coalescence phases. We then analyze the growth process, assuming that the evaporation is overcome by the precipitation rate, stabilizing all clusters with respect to dissolution back into the matrix. The problem was simplified neglecting anisotropy and the assuming a spherical shape for clusters and particles. The low interface tension was described in terms of an empirical potential barrier in the surface of the cluster. The growth dynamics developed considering that the number of clusters remains constant, and that the minimum size of these clusters grow with time, as the first order approximation showed a good agreement with the flaw. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
Cu(II)/neocuproine (2,9-dimethyl-1,10-phenanthroline) complexes were utilized for spectrophotometric determination of total polyphenol content in beers. This procedure is based on the reduction of Cu(II) by polyphenols in hydroethanolic medium (pH 7.0) in the presence of neocuproine, yielding Cu(I)/complexes with maximum absorption at 454 nm. The sensitivity of the proposed method was compared with the AOAC method using tannic and gallic acid as standards. The average apparent molar absorptivity, in L cm(-1) mol(-1), of tannic acid (3.50 +/- 0.20) x 10(5) and gallic acid (5.12 +/- 0.21) x 10(4), was twice as high for the proposed method. A lower limit of detection (LOD) (2.9 x 10(-1) mg L-1) was found when tannic acid was used in the proposed method. Additionally, less interference from the most common additives in beers was noticed. Total content of polyphenols was analyzed in 17 Brazilian samples. Results ranged from 35.5 to 556 mg L-1 of tannic acid, with higher values for recovery rates (45.4-118%, mean 85.0%) than for gallic acid. Although tannic acid is a mixture of polygalloyl glucoses, the total polyphenol content found in the samples suggests that tannic acid should be used as a standard. This is the first attempt to use this particular copper complex to quantify total polyphenol content in beer samples. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
This work aimed to apply genetic algorithms (GA) and particle swarm optimization (PSO) in cash balance management using Miller-Orr model, which consists in a stochastic model that does not define a single ideal point for cash balance, but an oscillation range between a lower bound, an ideal balance and an upper bound. Thus, this paper proposes the application of GA and PSO to minimize the Total Cost of cash maintenance, obtaining the parameter of the lower bound of the Miller-Orr model, using for this the assumptions presented in literature. Computational experiments were applied in the development and validation of the models. The results indicated that both the GA and PSO are applicable in determining the cash level from the lower limit, with best results of PSO model, which had not yet been applied in this type of problem.
Resumo:
We derive general rigorous lower bounds for the average ground state energy per site e ((d)) of the quantum and classical Edwards-Anderson spin-glass model in dimensions d=2 and d=3 in the thermodynamic limit. For the classical model they imply that e ((2))a parts per thousand yena'3/2 and e ((3))a parts per thousand yena'2.204a <-.
Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101