7 resultados para Lenses.

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gold plasmonic lenses consisting of a planar concentric rings-groove with different periods were milled with a focused gallium ion beam on a gold thin film deposited onto an Er3+-doped tellurite glass. The plasmonic lenses were vertically illuminated with an argon ion laser highly focused by means of a 50x objective lens. The focusing mechanism of the plasmonic lenses is explained using a coherent interference model of surface plasmon-polariton (SPP) generation on the circular grating due to the incident field. As a result, phase modulation can be accomplished by the groove gap, similar to a nanoslit array with different widths. This focusing allows a high confinement of SPPs that can excite the Er3+ ions of the glass. The Er3+ luminescence spectra were measured in the far-field (500-750 nm wavelength range), where we could verify the excitation yield via the plasmonic lens on the Er3+ ions. We analyze the influence of the geometrical parameters on the luminescence spectra. The variation of these parameters results in considerable changes of the luminescence spectra.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To describe a new method for iris fixation of intraocular lens in the absence of capsular support during penetrating keratoplasty. Its a new technique of iris fixation of intraocular lens without capsular support during penetrating keratoplasty. This technique is used in cases with a healthy iris and partial or total absence of capsular support during penetrating keratoplasty. Tied Out Open Sky is a technique easy to perform for iris fixation of intraocular lens during penetrating keratoplasty. The big advantage is being able to tie off the intraocular lens off the eye and fasten it securely.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sulcus anatomy and possible correlations between sulcus diameter and white-to-white (WTW) diameter in pseudophakic eyes, data that may be important in the stability of add-on intraocular lenses (IOLs). SETTING: University Eye Hospital, Tuebingen, Germany. DESIGN: Case series. METHODS: In pseudophakic eyes, the axial length (AL) and horizontal WTW were measured by the IOLMaster device. Cross-sectional images were obtained with a 50 MHz ultrasound biomicroscope on the 4 meridians: vertical, horizontal (180 degrees), temporal oblique, and nasal oblique. Sulcus-to-sulcus (STS), angle-to-angle (ATA), and sclera-to-sclera (ScTSc) diameters were measured. The IOL optic diameter (6.0 mm) served as a control. To test reliability, optic measurements were repeated 5 times in a subset of eyes. RESULTS: The vertical ATA and STS diameters were statistically significantly larger than the horizontal diameter (P=.0328 and P=.0216, respectively). There was no statistically significant difference in ScTSc diameters. A weak correlation was found between WTW and horizontal ATA (r = 0.5766, P<.0001) and between WTW and horizontal STS (r = 0.5040, P=.0002). No correlation was found between WTW and horizontal ScTSc (r = 0.2217, P=.1217). CONCLUSIONS: The sulcus anatomy had a vertical oval shape with the vertical meridian being the largest, but it also had variation in the direction of the largest meridian. The WTW measurements showed a weak correlation with STS. In pseudophakic eyes, Soemmerring ring or a bulky haptic may affect the ciliary sulcus anatomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effects of laser focusing and fluence on LIBS analysis of pellets of plant leaves was evaluated. A Q-switched Nd:YAG laser (5ns, 10Hz, 1064nm) was used and the emission signals were collected by lenses into an optical fiber coupled to a spectrometer with Echelle optics and ICCD. Data were acquired from the accumulation of 20 laser pulses at 2.0 mu s delay and 5.0 mu s integration time gate. The emission signal intensities increased with both laser fluence and spot size. Higher sensitivities for Ca, K, Mg, P, Al, B, Cu, Fe, Mn, and Zn determinations were observed for fluences in the range from 25 to 60Jcm(-2). Coefficients of variation of site-to-site measurements were generally lower than 10% (n=30 sites, 20 laser pulses/site) for a fluence of 50Jcm(-2) and 750 mu m spot size. For most elements, there is an indication that accuracy is improved with higher fluences. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Background The authors have developed a small portable device for the objective measurement of the transparency of corneas stored in preservative medium, for use by eye banks in evaluation prior to transplantation. Methods The optical system consists of a white light, lenses, and pinholes that collimate the white light beams and illuminate the cornea in its preservative medium, and an optical filter (400–700 nm) that selects the range of the wavelength of interest. A sensor detects the light that passes through the cornea, and the average corneal transparency is displayed. In order to obtain only the tissue transparency, an electronic circuit was built to detect a baseline input of the preservative medium prior to the measurement of corneal transparency. The operation of the system involves three steps: adjusting the "0 %" transmittance of the instrument, determining the "100 %" transmittance of the system, and finally measuring the transparency of the preserved cornea inside the storage medium. Results Fifty selected corneas were evaluated. Each cornea was submitted to three evaluation methods: subjective classification of transparency through a slit lamp, quantification of the transmittance of light using a corneal spectrophotometer previously developed, and measurement of transparency with the portable device. Conclusion By comparing the three methods and using the expertise of eye bank trained personnel, a table for quantifying corneal transparency with the new device has been developed. The correlation factor between the corneal spectrophotometer and the new device is 0,99813, leading to a system that is able to standardize transparency measurements of preserved corneas, which is currently done subjectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To describe an extremely uncommon outbreak of eye lesions in a specific area of the Brazilian Amazonia. Methods Prospective noncomparative case series. Fifty-nine patients who developed eye lesions after swimming in the Araguaia river of Tocantins state in Brazil were examined. A team of ophthalmologists equipped with a slit-lamp, gonioscopic lenses, and indirect ophthalmoscopy performed full eye examination. Analysis of the flora and fauna of the river water was undertaken by a group of experts. Results and Conclusions Eighty-three eyes were affected. The most common lesions were corneal opacities seen in 34 eyes and conjunctival nodules diagnosed in 12 eyes. Severe visual acuity loss was detected in seven children with unilateral anterior chamber lesions. Spicules of the sponge species Drulia uruguayensis and Drulia ctenosclera were found inside three blind eyes that have been enucleated for diagnostic purposes. All eye lesions could be attributed to an outbreak of foreign bodies from fresh water sponges. Organic enrichment of the water resulting from the absence of sanitation probably was the key factor, which initiated a cycle of ecological imbalance that provoked human disease.