Purpose: To evaluate biomechanical changes measured with the ORA (Ocular Response Analyzer (R); Reichert Ophthalmic Instruments, Buffalo, New York, USA) after Lasik with the Moria One Use Plus and to compare the biomechanics changes after myopic and hyperopic ablations. Methods: Fourteeneyes for hyperopia (H) and 19 eyes for myopia (M) were evaluated with the ORA preoperatively and 1 month after Lasik with thin flap (100 microns) using SBK-OUP (Sub-Bowman Keratomileusis-One Use Plus, Moria (R)). CH (Corneal Hysteresis), CRF (Corneal Resistance Factor), IOPg (gold-standard, Goldmann correlated Intraocular pressure), IOPcc (Corneal compensated Intraocular pressure) and more 38 variables derived from the corneal biomechanical response signal of the ORA were analyzed. The Wilcoxon test was used to assess differences between the variables before and after surgery for each group and the differences between the pre and postoperative (1 month) myopic eyes were compared with those obtained in hyperopic eyes, using the Mann-Whitney test. Results: There was a significant difference before and after Lasik in myopic and hyperopic eyes in IOPg (Wilcoxon, p<0.05), but not in IOPcc. Only myopic eyes showed a significant difference in CH and CRF measurements before and after LASIK, as well as 9 other biomechanical parameters (aspect1, h1, dive1, path1, p1area1, W11, H11, and w2 path11; Wilcoxon, p<0, 05), 8 of these being related to the first sign of flattening. Five parameters related to the sign of the second applanation showed significant variation only in the eyes before and after hyperopic Lasik (aspect2, h2, dive2, mslew2 and H21; Wilcoxon, p<0,05). There was a difference in both myopic and hyperopic on three parameters related to the applanation signal areas (p1area, and p2area p2area1; Wilcoxon, p<0.05). Differences in IOPg and p1area, before and after surgery were significantly higher in myopic eyes than in hyperopic eyes (Mann-Whitey, p<0.05). Conclusion: There are several significant differences in biomechanical parameters after Lasik with Moria OUP_SBK. Overall, the impact of myopic LASIK on corneal biomechanics is higher than of hyperopic Lasik. The parameters derived from the first sign of the ORA are more affected in myopic LASIK, whereas parameters derived from the second applanation are more affected in hyperopic LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The methodology currently used for interpretation of the cornea and anterior segment tomography for the diagnosis of corneal ectasia and its susceptibility. Methods: Description of the methodology and clinical interpretation of corneal and anterior segment tomography indexes; report of three cases demonstrating the importance of this new diagnostic tool (Pentacam HR (R)) in ophthalmological practice. Conclusion: The use of corneal and anterior segment tomography seems to be an effective method to increase the sensitivity and specificity for the diagnosis and early detection of corneal ectasia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess corneal wavefront-guided photorefractive keratectomy (PRK) to correct hyperopia after radial keratotomy (RK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. DESIGN: Case series. METHODS: Excimer laser corneal wavefront-guided PRK with intraoperative mitomycin-C (MMC) 0.02% was performed. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), corneal aberrations, and haze. RESULTS: The mean time between RK and PRK in the 61 eyes (39 patients) was 18.8 years +/- 3.8 (SD). Before PRK, the mean SE was +4.17 +/- 1.97 diopters (D); the mean astigmatism, -1.39 +/- 1.04 D; and the mean CDVA, 0.161 +/- 0.137 logMAR. At 24 months, the mean values were 0.14 +/- 0.99 D (P<.001), -1.19 +/- 1.02 D (P=.627), and 0.072 +/- 0.094 logMAR (P<.001), respectively; the mean UDVA was 0.265 +/- 0.196 (P<.001). The UDVA was 20/25 or better in 37.7% of eyes and 20/40 or better in 68.9%. The CDVA improved by 1 or more lines in 62.3% of eyes. Two eyes (3.3%) lost 2 or more lines, 1 due to corneal ectasia. Thirty eyes (49.2%) were within +/- 0.50 D of intended SE and 45 (73.8%) were within +/- 1.00 D. From 6 to 24 months, the mean SE regression was +0.39 D (P<.05). A significant decrease in coma, trefoil, and spherical aberration occurred. Three eyes developed peripheral haze more than grade 1. CONCLUSION: Corneal wavefront-guided PRK with MMC for hyperopia after RK significantly improved UDVA, CDVA, and higher-order corneal aberrations with a low incidence of visually significant corneal haze.