11 resultados para Kara, YosefKara, YosefYosefKara
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
PURPOSE: To determine whether the improvement in intermediate vision after bilateral implantation of an aspheric multifocal intraocular lens (IOL) with a +3.00 diopter (D) addition (add) occurs at the expense of optical quality compared with the previous model with a +4.00 D add. SETTING: Department of Ophthalmology, University of Sao Paulo, Sao Paulo, Brazil. DESIGN: Prospective randomized double-masked comparative clinical trial. METHODS: One year after bilateral implantation of Acrysof Restor SN6AD1 +3.00 D IOLs or Acrysof Restor SN6AD3 +4.00 D IOLs, optical quality was evaluated by analyzing the in vivo modulation transfer function (MTF) and point-spread function (expressed as Strehl ratio). The Strehl ratio and MTF curve with a 4.0 pupil and a 6.0 mm pupil were measured by dynamic retinoscopy aberrometry. The uncorrected and corrected distance visual acuities at 4 m, uncorrected and distance-corrected near visual acuities at 40 cm, and uncorrected and distance-corrected intermediate visual acuities at 50 cm, 60 cm, and 70 cm were measured. RESULTS: Both IOL groups comprised 40 eyes of 20 patients. One year postoperatively, there were no statistically significant between-group differences in the MTF or Strehl ratio with either pupil size. There were no statistically significant between-group differences in distance or near visual acuity. Intermediate visual acuity was significantly better in the +3.00 D IOL group. CONCLUSION: Results indicate that the improvement in intermediate vision in eyes with the aspheric multifocal +3.00 D add IOL occurred without decreasing optical quality over that with the previous version IOL with a +4.00 D add.
Resumo:
Purpose: To analyze the results of recall absent schoolchildren to eye health projects. Methods: Cross-sectional study. Visual screening was performed in schoolchildren attending 1st to 4th grades at public schools, from 7 to 10 years-old, to select and forward to complete ophthalmic evaluation. The projects were performed during weekends, at a public school, in the same municipality. Free transportation, food and eyeglasses were offered. A second opportunity of examination was offered to the students who were absent from the first call, with the same facilities. Results: 51,509 schoolchildren had their vision tested, 14,651 (28.4%) were referred for ophthalmic examination. Of these, 8,683 (59.3%) attended the first call, 2,228 (37.3%) attended the recall and 25.5% of parents did not take their children to ophthalmic examination. The need for eyeglasses for children who attended the examination was 23.8% and 32.0% in the first opportunity and recall, respectively. The recall increased the coverage in 15.2% (59.3% to 74.5%). Conclusion: An expressive number of parents (25.5%) did not bring their children to be examined, even at a second opportunity of exam. The facilities offered: access, free examination, transportation and glasses. Children who were absent in the first opportunity and appeared at recall had a greater need for eyeglasses. Recall increased the coverage in 15.2% (59.3% to 74.5%) and it is not recommended when financial resources are limited.
Resumo:
Purpose: To analyze emotional reactions related to cataract surgery in two groups of patients (monocular vision - Group 1; binocular vision - Group 2). Methods: A transversal comparative study was performed using a structured questionnaire from a previous exploratory study before cataract surgery. Results: 206 patients were enrolled in the study, 96 individuals in Group 1 (69.3 +/- 10.4 years) and 110 in Group 2 (68.2 +/- 10.2 years). Most patients in group 1 (40.6%) and 22.7% of group 2, reported fear of surgery (p<0.001). The most important causes of fear were: possibility of blindness, ocular complications and death during surgery. The most prevalent feelings among the groups were doubts about good results and nervousness. Conclusion: Patients with monocular vision reported more fear and doubts related to surgical outcomes. Thus, it is necessary that phisycians considers such emotional reactions and invest more time than usual explaining the risks and the benefits of cataract surgery. Ouvir
Resumo:
PURPOSE: To assess corneal wavefront-guided photorefractive keratectomy (PRK) to correct hyperopia after radial keratotomy (RK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. DESIGN: Case series. METHODS: Excimer laser corneal wavefront-guided PRK with intraoperative mitomycin-C (MMC) 0.02% was performed. Main outcome measures were uncorrected (UDVA) and corrected (CDVA) distance visual acuities, spherical equivalent (SE), corneal aberrations, and haze. RESULTS: The mean time between RK and PRK in the 61 eyes (39 patients) was 18.8 years +/- 3.8 (SD). Before PRK, the mean SE was +4.17 +/- 1.97 diopters (D); the mean astigmatism, -1.39 +/- 1.04 D; and the mean CDVA, 0.161 +/- 0.137 logMAR. At 24 months, the mean values were 0.14 +/- 0.99 D (P<.001), -1.19 +/- 1.02 D (P=.627), and 0.072 +/- 0.094 logMAR (P<.001), respectively; the mean UDVA was 0.265 +/- 0.196 (P<.001). The UDVA was 20/25 or better in 37.7% of eyes and 20/40 or better in 68.9%. The CDVA improved by 1 or more lines in 62.3% of eyes. Two eyes (3.3%) lost 2 or more lines, 1 due to corneal ectasia. Thirty eyes (49.2%) were within +/- 0.50 D of intended SE and 45 (73.8%) were within +/- 1.00 D. From 6 to 24 months, the mean SE regression was +0.39 D (P<.05). A significant decrease in coma, trefoil, and spherical aberration occurred. Three eyes developed peripheral haze more than grade 1. CONCLUSION: Corneal wavefront-guided PRK with MMC for hyperopia after RK significantly improved UDVA, CDVA, and higher-order corneal aberrations with a low incidence of visually significant corneal haze.
Resumo:
Objective: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. Methods: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the Sao Joao da Boa Vista Administrative Region). Results: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. Conclusion: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolandia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.
Resumo:
PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.
Resumo:
OBJETIVO: Analisar a incidência e causas de cancelamento de cirurgias de catarata em um hospital público de referência. MÉTODOS: Trata-se de um estudo retrospectivo em que foram analisados o número de cancelamentos de facectomias durante o ano de 2009. Foram analisados sexo, idade, tipo de procedimento suspenso (facoemulsificação ou extração extracapsular do cristalino), tipo de anestesia, convênio (Sistema Único de Saúde ou convênio/particular) e motivo de suspensão da cirurgia (causas clínicas, institucionais ou pessoais). RESULTADOS: Foram agendadas no período 2.965 cirurgias de catarata, havendo 650 cancelamentos (21,92%). Dentre as principais razões para a suspensão do procedimento destacaram-se as causas clínicas (86,90%). Os meses de inverno apresentaram os maiores índices de suspensão de cirurgias de catarata. CONCLUSÃO: A taxa de cancelamento de cirurgia de catarata em serviços públicos parece ser a mesma que há 10 anos. A principal causa de suspensão deve-se por condições clínicas (hipertensão, diabetes, falta de exames, etc.).
Resumo:
OBJETIVO: Comparar custos da cirurgia de catarata em larga escala para um hospital público, para o governo e para a sociedade, pelas técnicas de facoemulsificação (FACO) e extração extracapsular (EECP). MÉTODOS: Foi realizada revisão baseada principalmente em diversos estudos clínicos realizados entre 2002 e 2010, no Centro Cirúrgico Ambulatorial do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo. RESULTADOS: Os gastos estimados com os insumos utilizados para as cirurgias foram de R$ 468,92 no grupo FACO e R$ 259,96 no grupo EECP. As despesas hospitalares com o acompanhamento pós-operatório foram em média de R$ 16,40 (42%) menores no grupo FACO. Com relação ao gasto estimado para a Previdência Social, o grupo EECP custou em média, US$ 44,58 por paciente a mais que o grupo FACO. CONCLUSÃO: O incentivo e o investimento governamental para a realização da FACO no SUS são socialmente justificados, deve-se considerar também a economia dos pacientes e do sistema empresarial, bem como as vantagens clínicas para os pacientes e vantagens econômicas para os hospitais.
Resumo:
OBJECTIVE: To assess the waiting time for eye care identifying the number of patients with each complaint; to investigate how the waiting time may worsen the patient's condition; to check the screening of urgent cases for effectiveness; and to devise means of increasing the medical-surgical care capacity. METHODS: A retrospective descriptive survey was conducted using data obtained on 12 occasions during collaborative team visits to provide eyecare services. These initiatives were designed to decrease the waiting time and to treat urgent cases that occurred on each occasion; eyecare services were provided every Saturday, in the period from June to August 2006, in 16 cities of the region covered by Conderg (Consortium for the Development of the São João da Boa Vista Administrative Region). RESULTS: Referrals used 1,743 (87.1%) of the 2,000 places available. The most frequent diagnoses were refractive errors, with 683 cases, corresponding to 39.1% of the total, followed by cataracts, with 296 cases, corresponding to 20.9%. Of the 238 surgeries indicated, 54.6% were phakectomies. Thirty-five (2.0%) cases were considered urgent. CONCLUSION: The most common diagnoses made during the team visits to manage the excess demand for eyecare were refractive errors and cataracts, which, together, accounted for the majority of the cases. The Divinolândia Hospital has the necessary human and material resources to meet the demand left unattended by the local SUS network. Immediate referral of urgent cases by the primary units' screeners proved effective.
Resumo:
OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.