2 resultados para International Standards for the Professional Practice of Internal Auditing
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Abstract Background The Brazilian Study on the Practice of Diabetes Care main objective was to provide an epidemiological profile of individuals with type 1 and 2 diabetes mellitus (DM) in Brazil, concerning therapy and adherence to international guidelines in the medical practice. Methods This observational, cross-sectional, multicenter study collected and analyzed data from individuals with type 1 and 2 DM attending public or private clinics in Brazil. Each investigator included the first 10 patients with type 2 DM who visited his/her office, and the first 5 patients with type 1 DM. Results A total of 1,358 patients were analyzed; 375 (27.6%) had type 1 and 983 (72.4%) had type 2 DM. Most individuals were women, Caucasian, and private health care users. High prevalence rates of hypertension, dyslipidemia and central obesity were observed, particularly in type 2 DM. Only 7.3% and 5.1% of the individuals with types 1 and 2 DM, respectively, had optimal control of blood pressure, plasma glucose and lipids. The absence of hypertension and female sex were associated with better control of type 1 DM and other cardiovascular risk factors. In type 2 DM, older age was also associated with better control. Conclusions Female sex, older age, and absence of hypertension were associated with better metabolic control. An optimal control of plasma glucose and other cardiovascular risk factors are obtained only in a minority of individuals with diabetes. Local numbers, compared to those from other countries are worse.
Resumo:
There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.