9 resultados para Instruments of pilotage

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The results obtained in the August and December 2003, August 2004 and January 2005 oceanographic campaigns in the northern region of the Todos os Santos Bay (lat. 12 degrees 44.5`S; long. 038 degrees 35.00`W) between the Madre de Deus and Mare islands are analyzed. Instruments of continuous and discrete samplings were used to measure hydrographic properties currents and tides. The water mass of the northern region of the bay is forced by semidiurnal and mesotides of form number 0.08 and the lunar component M(2) height was estimated at 91cm. The time series of the surface currents indicated movements in the N/S direction, forced by the tide with maximum magnitudes of 0.73 m.s(-1) on the December 2003 campaign. However, in August 2004 the currents were dominated by the wind stress forcing, with a maximum speed of 1.85 m.s(-1) and SE direction. Near the bottom, the influence of the tide is not as evident, with a decrease in intensity due to internal and bottom friction, with a maximum velocity of 0.17 m.s(-1). The thermal and haline structures were weakly horizontally, as well as vertically stratified, with extreme values varying in the intervals 23 degrees C (August, 2004) to 28 degrees C (December, 2003) and 31.0 psu (August, 2003) to 36.0 psu (December, 2003), respectively. Some conclusions may be drawn from these results: i) The signs of the dilution of the fresh water discharges of the Caipe, Mataripe and Sao Paulo rivers in the region under the influence of the RLAM were observed only during the winter periods, but in the summer the region was flooded by waters of oceanic origin and the salinities above 36.0 indicated TW mass intrusion; ii) The N-S circulation near the RLAM is strongly dominated by the tide, and the importance of the M(2) component was unequivocal, however, the E-W component presented some tidal modulation away from abrupt bottom topographical changes, and iii) The residual series, calculated as the difference between the original and modeled, is about 1/4 of the original and confirmed its semidiurnal character.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective. To evaluate the clinical features of obsessive-compulsive disorder (OCD) patients with comorbid tic disorders (TD) in a large, multicenter, clinical sample. Method. A cross-sectional study was conducted that included 813 consecutive OCD outpatients from the Brazilian OCD Research Consortium and used several instruments of assessment, including the Yale-Brown Obsessive-Compulsive Scale, the Dimensional Yale-Brown Obsessive-Compulsive Scale, the Yale Global Tic Severity Scale (YGTSS), the USP Sensory Phenomena Scale, and the Structured Clinical Interview for DSM-IV Axis I Disorders. Results. The sample mean current age was 34.9 years old (SE 0.54), and the mean age at obsessive-compulsive symptoms (OCS) onset was 12.8 years old (SE 0.27). Sensory phenomena were reported by 585 individuals (72% of the sample). The general lifetime prevalence of TD was 29.0% (n=236), with 8.9% (n=72) presenting Tourette syndrome, 17.3% (n=5141) chronic motor tic disorder, and 2.8% (n=523) chronic vocal tic disorder. The mean tic severity score, according to the YGTSS, was 27.2 (SE 1.4) in the OCD1TD group. Compared to OCD patients without comorbid TD, those with TD (OCD1TD group, n=236) were more likely to be males (49.2% vs. 38.5%, p<005) and to present sensory phenomena and comorbidity with anxiety disorders in general: separation anxiety disorder, social phobia, specific phobia, generalized anxiety disorder, post-traumatic stress disorder, attention-deficit hyperactivity disorder, impulse control disorders in general, and skin picking. Also, the "aggressive," "sexual/religious," and "hoarding" symptom dimensions were more severe in the OCD+TD group. Conclusion. Tic-related OCD may constitute a particular subgroup of the disorder with specific phenotypical characteristics, but its neurobiological underpinnings remain to be fully disentangled.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Justificativa e objetivos: As ligas acadêmicas vêm se firmando como instrumentos de ensino médico e inserção dos estudantes de medicina na prática das especialidades, inclusive na anestesiologia. Como o papel das ligas no processo de desenvolvimento de competências e aprendizado de seus alunos não é bem conhecido, avaliou-se o aprendizado dos integrantes de uma liga acadêmica de anestesiologia após um ano de participação nas suas atividades. MÉTODO: Os alunos de uma liga acadêmica de anestesiologia foram acompanhados de março a dezembro de 2010 e avaliados por meio de testes cognitivos objetivos de múltipla escolha aplicados antes do início das atividades e após sua conclusão. A frequência nas atividades e o perfil epidemiológico dos alunos foram correlacionados aos resultados dos testes. RESULTADOS: Foram analisados 20 acadêmicos do 3º ao 6º ano, com média de idade de 22,8 (21-26) anos. A frequência média nas atividades propostas foi 10,4/13 (80%). A média de acertos no primeiro teste foi 8,1/17 (47,6%), sendo que os alunos do 3º ano apresentam notas menores (p < 0,02) em relação aos demais. No teste pós-liga, a média de acertos foi 11,9/17 (70%), mostrando melhora no desempenho dos alunos (p < 0,05), e não houve diferença entre as notas dos diferentes anos da graduação. Foi encontrada relação forte entre frequência nas atividades e melhora nas notas (r = 0,719; p < 0,001). CONCLUSÕES: Os alunos que participaram da liga apresentaram melhora nos testes de avaliação de conhecimento, sugerindo que a liga é útil instrumento de ensino e promove ganho de aprendizado em anestesiologia. As atividades desenvolvidas nas ligas podem ter papel positivo na formação acadêmica dos graduandos, destacando-se, neste artigo, a anestesiologia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work assessed homogeneity of the Institute of Astronomy, Geophysics and Atmospheric Sciences (IAG) weather station climate series, using various statistical techniques. The record from this target station is one of the longest in Brazil, having commenced in 1933 with observations of precipitation, and temperatures and other variables later in 1936. Thus, it is one of the few stations in Brazil with enough data for long-term climate variability and climate change studies. There is, however, a possibility that its data may have been contaminated by some artifacts over time. Admittedly, there was an intervention on the observations in 1958, with the replacement of instruments, for which the size of impact has not been yet evaluated. The station transformed in the course of time from rural to urban, and this may also have influenced homogeneity of the observations and makes the station less representative for climate studies over larger spatial scales. Homogeneity of the target station was assessed applying both absolute, or single station tests, and tests relatively to regional climate, in annual scale, regarding daily precipitation, relative humidity, maximum (TMax), minimum (TMin), and wet bulb temperatures. Among these quantities, only precipitation does not exhibit any inhomogeneity. A clear signal of change of instruments in 1958 was detected in the TMax and relative humidity data, the latter certainly because of its strong dependence on temperature. This signal is not very clear in TMin, but it presents non-climatic discontinuities around 1953 and around 1970. A significant homogeneity break is found around 1990 for TMax and wet bulb temperature. The discontinuities detected after 1958 may have been caused by urbanization, as the observed warming trend in the station is considerably greater than that corresponding to regional climate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we investigate the influence of extractives, lignin and holocellulose contents on performance index (PI) of seven woods used or tested for violin bows. Woods with higher values of this index (PI = root MOE/rho, where MOE is modulus of elasticity and rho is density) have a higher bending stiffness at a given mass, which can be related to bow wood quality. Extractive content was negatively correlated with PI in Caesalpinia echinata, Hanclroanthus sp. and Astronium lecointei. In C. echinata holocellulose was positively correlated with PI. These results need to be further explored with more samples and by testing additional wood properties. Although the chemical constituents could provide an indication of quality, it is not possible to establish appropriate woods for bows solely by examining their chemical constituents.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficacy of three rotary instrument systems (K3, Pro Taper and Twisted File) in removing calcium hydroxide residues from root canal walls. Thirty-four human mandibular incisors were instrumented with the Pro Taper System up to the F2 instrument, irrigated with 2.5% NaOCl followed by 17% EDTA, and filled with a calcium hydroxide intracanal dressing. After 7 days, the calcium hydroxide dressing was removed using the following rotary instruments: G1. - NiTi size 25, 0.06 taper, of the K3 System; G2 - NiTi F2, of the Pro Taper System; or G3 - NiTi size 25, 0.06 taper, of the Twisted File System. The teeth were longitudinally grooved on the buccal and lingual root surfaces, split along their long axis, and their apical and cervical canal thirds were evaluated by SEM (x1000). The images were scored and the data were statistically analyzed using the Kruskall Wallis test. None of the instruments removed the calcium hydroxide dressing completely, either in the apical or cervical thirds, and no significant differences were observed among the rotary instruments tested (p > 0.05).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods: The operators prepared one canal with RaCe rotary instruments and another with Flexofiles. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radial's, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results: There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion: The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Introduction: The aim of this study was to assess the effect of nitrogen ion implantation on the flexibility of rotary nickel-titanium (NiTi) instruments as measured by the load required to bend implanted and nonimplanted instruments at a 30 degrees angle. Methods: Thirty K3 files, size #40, 0.02 taper and 25-mm length, were allocated into 2 groups as follows: group A, 15 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), voltage 200 KeV, current density 1 mu A/cm(2), temperature 130 degrees C, and vacuum conditions of 10 x 10(-6) mm Hg for 6 hours; and group B, 15 nonimplanted files. One extra file was used for process control. All instruments were subjected to bend testing on a modified troptometer, with measurement of the load required for flexure to an angle of 30 degrees. The Mann-Whitney U test was used for statistical analysis. Findings with P <.05 were considered significant. Results: The mean load required to bend instruments at a 30 degrees angle was 376.26 g for implanted instruments and 383.78 g for nonimplanted instruments. The difference was not statistically significant. Conclusions: Our findings show that nitrogen ion implantation has no appreciable effect on the flexibility of NiTi instruments. (J Endod 2012;38:673-675)