4 resultados para Impressão plantar
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Optimal levels of noise stimulation have been shown to enhance the detection and transmission of neural signals thereby improving the performance of sensory and motor systems. The first series of experiments in the present study aimed to investigate whether subsensory electrical noise stimulation applied over the triceps surae (TS) in seated subjects decreases torque variability during a force-matching task of isometric plantar flexion and whether the same electrical noise stimulation decreases postural sway during quiet stance. Correlation tests were applied to investigate whether the noise-induced postural sway decrease is linearly predicted by the noise-induced torque variability decrease. A second series of experiments was conducted to investigate whether there are differences in torque variability between conditions in which the subsensory electrical noise is applied only to the TS, only to the tibialis anterior (TA) and to both TS and TA, during the force-matching task with seated subjects. Noise stimulation applied over the TS muscles caused a significant reduction in force variability during the maintained isometric force paradigm and also decreased postural oscillations during quiet stance. Moreover, there was a significant correlation between the reduction in force fluctuation and the decrease in postural sway with the electrical noise stimulation. This last result indicates that changes in plantar flexion force variability in response to a given subsensory random stimulation of the TS may provide an estimate of the variations in postural sway caused by the same subsensory stimulation of the TS. We suggest that the decreases in force variability and postural sway found here are due to stochastic resonance that causes an improved transmission of proprioceptive information. In the second series of experiments, the reduction in force variability found when noise was applied to the TA muscle alone did not reach statistical significance, suggesting that TS proprioception gives a better feedback to reduce force fluctuation in isometric plantar flexion conditions.
Resumo:
Objective: To compare individuals with and without hyperhidrosis in terms of the intensity of palmar and plantar sweating. Methods: We selected 50 patients clinically diagnosed with palmoplantar hyperhidrosis and 25 normal individuals as controls. We quantified sweating using a portable noninvasive electronic device that has relative humidity and temperature sensors to measure transepidermal water loss. All of the individuals had a body mass index of 20-25 kg/cm(2). Subjects remained at rest for 20-30 min before the measurements in order to reduce external interference. The measurements were carried out in a climate-controlled environment (21-24 degrees C). Measurements were carried out on the hypothenar region on both hands and on the medial plantar region on both feet. Results: In the palmoplantar hyperhidrosis group, the mean transepidermal water loss on the hands and feet was 133.6 +/- 51.0 g/m(2)/h and 71.8 +/- 40.3 g/m(2)/h, respectively, compared with 37.9 +/- 18.4 g/m(2)/h and 27.6 +/- 14.3 g/m(2)/h, respectively, in the control group. The differences between the groups were statistically significant (p < 0.001 for hands and feet). Conclusions: This method proved to be an accurate and reliable tool to quantify palmar and plantar sweating when performed by a trained and qualified professional.
Resumo:
Background: High-frequency trains of electrical stimulation applied over the human muscles can generate forces higher than would be expected by direct activation of motor axons, as evidenced by an unexpected relation between the stimuli and the evoked contractions, originating what has been called “extra forces”. This phenomenon has been thought to reflect nonlinear input/output neural properties such as plateau potential activation in motoneurons. However, more recent evidence has indicated that extra forces generated during electrical stimulation are mediated primarily, if not exclusively, by an intrinsic muscle property, and not from a central mechanism as previously thought. Given the inherent differences between electrical and vibratory stimuli, this study aimed to investigate: (a) whether the generation of vibration-induced muscle forces results in an unexpected relation between the stimuli and the evoked contractions (i.e. extra forces generation) and (b) whether these extra forces are accompanied by signs of a centrally-mediated mechanism or whether intrinsic muscle properties are the redominant mechanisms. Methods: Six subjects had their Achilles tendon stimulated by 100 Hz vibratory stimuli that linearly increased in amplitude (with a peak-to-peak displacement varying from 0 to 5 mm) for 10 seconds and then linearly decreased to zero for the next 10 seconds. As a measure of motoneuron excitability taken at different times during the vibratory stimulation, short-latency compound muscle action potentials (V/F-waves) were recorded in the soleus muscle in response to supramaximal nerve stimulation. Results: Plantar flexion torque and soleus V/F-wave amplitudes were increased in the second half of the stimulation in comparison with the first half. Conclusion: The present findings provide evidence that vibratory stimuli may trigger a centrally-mediated mechanism that contributes to the generation of extra torques. The vibration-induced increased motoneuron excitability (leading to increased torque generation) presumably activates spinal motoneurons following the size principle, which is a desirable feature for stimulation paradigms involved in rehabilitation programs and exercise training.
Resumo:
OBJETIVO: Demonstrar os achados em ressonância magnética (RM) da tromboflebite plantar. MÉTODOS: Revisão retrospectiva de 20 pacientes com dor na região plantar nos quais os achados de ressonância magnética indicaram tromboflebite plantar. RESULTADOS: Foram avaliados 14 homens e seis mulheres, com idade média de 46,7 anos. Oito desses pacientes também foram submetidos à ultrassonografia com doppler, que confirmaram a tromboflebite. As imagens de ressonância magnética foram avaliadas em consenso por dois radiologistas com experiência em radiologia do sistema musculoesquelético (mais de 10 anos cada um), demonstrando edema perivascular em todos os 20 pacientes (100%) e edema muscular em 19 dos 20 pacientes (95%). Todos os 20 pacientes apresentavam intensidade de sinal intermediária intraluminal em T2 (100%) e ectasia venosa estava presente em 17 dos 20 casos (85%). Veias colaterais foram visualizadas em um dos 20 pacientes (5%). Todos os 14 casos (100%), nos quais o contraste intravenoso foi administrado, apresentavam realce dos tecidos perivenulares e defeito de enchimento intraluminal. Ectasia venosa, perda da compressibilidade e ausência de fluxo na ultrassonografia com doppler também foram observados em todos os oito casos examinados pelo método. CONCLUSÕES: A RM é um método sensível na avaliação de tromboflebite plantar em pacientes com dor plantar.