6 resultados para Home monitoring system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: This pilot study aimed to verify if glycemic control can be achieved in type 2 diabetes patients after acute myocardial infarction (AMI), using insulin glargine (iGlar) associated with regular insulin (iReg), compared with the standard intensive care unit protocol, which uses continuous insulin intravenous delivery followed by NPH insulin and iReg (St. Care). Patients and Methods: Patients (n = 20) within 24 h of AMI were randomized to iGlar or St. Care. Therapy was guided exclusively by capillary blood glucose (CBG), but glucometric parameters were also analyzed by blinded continuous glucose monitoring system (CGMS). Results: Mean glycemia was 141 +/- 39 mg/dL for St. Care and 132 +/- 42 mg/dL for iGlar by CBG or 138 +/- 35 mg/dL for St. Care and 129 +/- 34 mg/dL for iGlar by CGMS. Percentage of time in range (80-180 mg/dL) by CGMS was 73 +/- 18% for iGlar and 77 +/- 11% for St. Care. No severe hypoglycemia (<= 40 mg/dL) was detected by CBG, but CGMS indicated 11 (St. Care) and seven (iGlar) excursions in four subjects from each group, mostly in sulfonylurea users (six of eight patients). Conclusions: This pilot study suggests that equivalent glycemic control without increase in severe hyperglycemia may be achieved using iGlar with background iReg. Data outputs were controlled by both CBG and CGMS measurements in a real-life setting to ensure reliability. Based on CGMS measurements, there were significant numbers of glycemic excursions outside of the target range. However, this was not detected by CBG. In addition, the data indicate that previous use of sulfonylurea may be a potential major risk factor for severe hypoglycemia irrespective of the type of insulin treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Pierre Auger Observatory is a facility built to detect air showers produced by cosmic rays above 10(17) eV. During clear nights with a low illuminated moon fraction, the UV fluorescence light produced by air showers is recorded by optical telescopes at the Observatory. To correct the observations for variations in atmospheric conditions, atmospheric monitoring is performed at regular intervals ranging from several minutes (for cloud identification) to several hours (for aerosol conditions) to several days (for vertical profiles of temperature, pressure, and humidity). In 2009, the monitoring program was upgraded to allow for additional targeted measurements of atmospheric conditions shortly after the detection of air showers of special interest, e. g., showers produced by very high-energy cosmic rays or showers with atypical longitudinal profiles. The former events are of particular importance for the determination of the energy scale of the Observatory, and the latter are characteristic of unusual air shower physics or exotic primary particle types. The purpose of targeted (or "rapid") monitoring is to improve the resolution of the atmospheric measurements for such events. In this paper, we report on the implementation of the rapid monitoring program and its current status. The rapid monitoring data have been analyzed and applied to the reconstruction of air showers of high interest, and indicate that the air fluorescence measurements affected by clouds and aerosols are effectively corrected using measurements from the regular atmospheric monitoring program. We find that the rapid monitoring program has potential for supporting dedicated physics analyses beyond the standard event reconstruction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background Recurrent nerve injury is 1 of the most important complications of thyroidectomy. During the last decade, nerve monitoring has gained increasing acceptance in several centers as a method to predict and to document nerve function at the end of the operation. We evaluated the efficacy of a nerve monitoring system in a series of patients who underwent thyroidectomy and critically analyzed the negative predictive value (NPV) and positive predictive value (PPV) of the method. Methods. NIM System efficacy was prospectively analyzed in 447 patients who underwent thyroidectomy between 2001 and 2008 (366 female/81 male; 420 white/47 nonwhite; 11 to 82 years of age; median, 43 years old). There were 421 total thyroidectomies and 26 partial thyroidectomies, leading to 868 nerves at risk. The gold standard to evaluate inferior laryngeal nerve function was early postoperative videolaryngoscopy, which was repeated after 4 to 6 months in all patients with abnormal endoscopic findings. Results. At the early evaluation, 858 nerves (98.8%) presented normal videolaryngoscopic features after surgery. Ten paretic/paralyzed nerves (1.2%) were detected (2 unexpected unilateral paresis, 2 unexpected bilateral paresis, 1 unexpected unilateral paralysis, 1 unexpected bilateral paralyses, and 1 expected unilateral paralysis). At the late videolaryngoscopy, only 2 permanent nerve paralyses were noted (0.2%), with an ultimate result of 99.8% functioning nerves. Nerve monitoring showed absent or markedly reduced electrical activity at the end of the operations in 25/868 nerves (2.9%), including all 10 endoscopically compromised nerves, with 15 false-positive results. There were no false-negative results. Therefore, the PPV was 40.0%, and the NPV was 100%. Conclusions. In the present series, nerve monitoring had a very high PPV but a low NPV for the detection of recurrent nerve injury. (C) 2011 Wiley Periodicals, Inc. Head Neck 34: 175-179, 2012

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Data visualization techniques are powerful in the handling and analysis of multivariate systems. One such technique known as parallel coordinates was used to support the diagnosis of an event, detected by a neural network-based monitoring system, in a boiler at a Brazilian Kraft pulp mill. Its attractiveness is the possibility of the visualization of several variables simultaneously. The diagnostic procedure was carried out step-by-step going through exploratory, explanatory, confirmatory, and communicative goals. This tool allowed the visualization of the boiler dynamics in an easier way, compared to commonly used univariate trend plots. In addition it facilitated analysis of other aspects, namely relationships among process variables, distinct modes of operation and discrepant data. The whole analysis revealed firstly that the period involving the detected event was associated with a transition between two distinct normal modes of operation, and secondly the presence of unusual changes in process variables at this time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This qualitative study was performed with 71 hypertensive patients, with the objectives to compare outpatient and home blood pressure monitoring (HBPM), to assess blood pressure control, and characterize white-coat hypertension. A nurse performed the outpatient blood pressure measurement. The home blood pressure monitoring was carried out over seven days. White-coat hypertension was quantified as a difference between the outpatient measurement and home blood pressure monitoring in the ranges from 1 to 5, 6 to 10 and > 10 mmHg. The outpatient blood pressure measurement was significantly higher (p<0.05) than the home blood pressure measurement. Pressure control corresponded to 9.9% in the outpatient measurement and 23.9% in the home blood pressure measurement. The white-coat effect > 10 mmHg was 57.7% for systolic and 32.4% for diastolic pressure, in the range from 6 to 10 mmHg. Home blood pressure measurement provided a better assessment of hypertensive patients' control.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract Background A typical purification system that provides purified water which meets ionic and organic chemical standards, must be protected from microbial proliferation to minimize cross-contamination for use in cleaning and preparations in pharmaceutical industries and in health environments. Methodology Samples of water were taken directly from the public distribution water tank at twelve different stages of a typical purification system were analyzed for the identification of isolated bacteria. Two miniature kits were used: (i) identification system (api 20 NE, Bio-Mérieux) for non-enteric and non-fermenting gram-negative rods; and (ii) identification system (BBL crystal, Becton and Dickson) for enteric and non-fermenting gram-negative rods. The efficiency of the chemical sanitizers used in the stages of the system, over the isolated and identified bacteria in the sampling water, was evaluated by the minimum inhibitory concentration (MIC) method. Results The 78 isolated colonies were identified as the following bacteria genera: Pseudomonas, Flavobacterium and Acinetobacter. According to the miniature kits used in the identification, there was a prevalence of isolation of P. aeruginosa 32.05%, P. picketti (Ralstonia picketti) 23.08%, P. vesiculares 12.82%,P. diminuta 11.54%, F. aureum 6.42%, P. fluorescens 5.13%, A. lwoffi 2.56%, P. putida 2.56%, P. alcaligenes 1.28%, P. paucimobilis 1.28%, and F. multivorum 1.28%. Conclusions We found that research was required for the identification of gram-negative non-fermenting bacteria, which were isolated from drinking water and water purification systems, since Pseudomonas genera represents opportunistic pathogens which disperse and adhere easily to surfaces, forming a biofilm which interferes with the cleaning and disinfection procedures in hospital and industrial environments.