Bone mass was only previously studied in juvenile dermatomyositis/polymyositis (DM/PM) patients. Therefore, the objective this study was to evaluate the prevalence of osteoporosis and fractures in adult DM/PM. Forty female DM/PM and 78 age-, gender-, and BMI-matched healthy controls were studied. Medical charts and clinical interviews of all patients were evaluated for demographic and clinical data, including disease activity, cumulative doses of glucocorticoid, menarche and menopause age, and fractures. Bone mineral density (BMD) using dual X-ray absorptiometry (DXA) were measured at lumbar spine (L1-L4) and hip. A decreased BMD in lumbar spine [0.902 (0.136) vs. 0.965 (0.141) g/cm(2), P = 0.022] and femoral neck [0.729 (0.12) vs. 0.784 (0.127) g/cm(2), P = 0.027] was observed in patients compared to controls. In addition, osteoporosis was more frequent in patients than in controls in both lumbar spine (20 vs. 3.8%, P = 0.007) and the femoral neck (27.5 vs. 10.3%, P = 0.016). Moreover, a high prevalence of fractures was found in patients in comparison to healthy subjects (17.9 vs. 5.1%, P = 0.040; OR = 3.92; CI 95%: 1.07-14.33). Comparing DM/PM patients with (n = 17) and without (n = 23) osteoporosis/fractures, significant differences were observed regarding age [56.8 (11.9) vs. 48.3 (13.2) years, P = 0.042], weight [62.05 (13.56) vs. 71.51 (11.46) kg, P = 0.022] and frequency of post menopausal women (94.1 vs. 65.2%, P = 0.0002). No differences were observed concerning height, lean mass, total fat mass, disease activity, mean value of creatine kinase, cumulative glucocorticoid dose, or bisphosphonate use. Logistic regression analysis revealed a negative association between the presence of osteoporosis/fractures and weight (OR: 0.92, 95% CI: 0.85-0.98; P = 0.016). This is the first study that analyzed bone mass in adult DM/PM patients and it demonstrated that about one quarter of these patients have osteoporosis/fracture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aim: We evaluated the effectiveness of high-frequency transcutaneous electrical nerve stimulation (TENS) as a pain relief resource for primiparous puerpere who had experienced natural childbirth with an episiotomy. Methods: A controlled, randomized clinical study was conducted in a Brazilian maternity ward. Forty puerpere were randomly divided into two groups: TENS high frequency and a no treatment control group. Post-episiotomy pain was assessed in the resting and sitting positions and during ambulation. An 11-point numeric rating scale was performed in three separate evaluations (at the beginning of the study, after 60 min and after 120 min). The McGill pain questionnaire was employed at the beginning and 60 min later. TENS with 100 Hz frequency and 75 mu s pulse for 60 min was employed without causing any pain. Four electrodes ware placed in parallel near the episiotomy site, in the area of the pudendal and genitofemoral nerves. Results: An 11-point numeric rating scale and McGill pain questionnaire showed a significant statistical difference in pain reduction in the TENS group, while the control group showed no alteration in the level of discomfort. Hence, high-frequency TENS treatment significantly reduced pain intensity immediately after its use and 60 min later. Conclusion: TENS is a safe and viable non-pharmacological analgesic resource to be employed for pain relief post-episiotomy. The routine use of TENS post-episiotomy is recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Understanding how magnetic materials respond to rapidly varying magnetic fields, as in dynamic hysteresis loops, constitutes a complex and physically interesting problem. But in order to accomplish a thorough investigation, one must necessarily consider the effects of thermal fluctuations. Albeit being present in all real systems, these are seldom included in numerical studies. The notable exceptions are the Ising systems, which have been extensively studied in the past, but describe only one of the many mechanisms of magnetization reversal known to occur. In this paper we employ the Stochastic Landau-Lifshitz formalism to study high-frequency hysteresis loops of single-domain particles with uniaxial anisotropy at an arbitrary temperature. We show that in certain conditions the magnetic response may become predominantly out-of-phase and the loops may undergo a dynamic symmetry loss. This is found to be a direct consequence of the competing responses due to the thermal fluctuations and the gyroscopic motion of the magnetization. We have also found the magnetic behavior to be exceedingly sensitive to temperature variations, not only within the superparamagnetic-ferromagnetic transition range usually considered, but specially at even lower temperatures, where the bulk of interesting phenomena is seen to take place. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, barium zirconate (BaZrO3) ceramics synthesized by solid state reaction method and sintered at 1670 degrees C for 4 h were characterized by X-ray diffraction (XRD), Rietveld refinement, and Fourier transform infrared (FT-IR) spectroscopy. XRD patterns, Rietveld refinement data and FT-IR spectra which confirmed that BaZrO3 ceramics have a perovskite-type cubic structure. Optical properties were investigated by ultraviolet-visible (UV-vis) absorption and photoluminescence (PL) measurements. UV-vis absorption spectra suggested an indirect allowed transition with the existence of intermediary energy levels within the band gap. Intense visible green PL emission was observed in BaZrO3 ceramics upon excitation with a 350 nm wavelength. This behavior is due to a majority of deep defects within the band gap caused by symmetry breaking in octahedral [ZrO6] clusters in the lattice. The microwave dielectric constant and quality factor were measured using the method proposed by Hakki-Coleman. The dielectric resonator antenna (DRA) was investigated experimentally and numerically using a monopole antenna through an infinite ground plane and Ansoft's high frequency structure simulator software, respectively. The required resonance frequency and bandwidth of DRA were investigated by adjusting the dimension of the same material. (C) 2011 Elsevier Ltd and Techna Group S.r.l. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The use of the core-annular flow pattern, where a thin fluid surrounds a very viscous one, has been suggested as an attractive artificial-lift method for heavy oils in the current Brazilian ultra-deepwater production scenario. This paper reports the pressure drop measurements and the core-annular flow observed in a 2 7/8-inch and 300 meter deep pilot-scale well conveying a mixture of heavy crude oil (2000 mPa.s and 950 kg/m3 at 35 C) and water at several combinations of the individual flow rates. The two-phase pressure drop data are compared with those of single-phase oil flow to assess the gains due to water injection. Another issue is the handling of the core-annular flow once it has been established. High-frequency pressure-gradient signals were collected and a treatment based on the Gabor transform together with neural networks is proposed as a promising solution for monitoring and control. The preliminary results are encouraging. The pilot-scale tests, including long-term experiments, were conducted in order to investigate the applicability of using water to transport heavy oils in actual wells. It represents an important step towards the full scale application of the proposed artificial-lift technology. The registered improvements in terms of oil production rate and pressure drop reductions are remarkable.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The current research compared resting heart rate variability (VFC) before and after 10 weeks of strength training in groups that used and did not use a vibration platform. Seventeen healthy men were divided into conventional strength training (TF) or strength training using a vibration platform with a frequency of 30 Hz (TF+V30) training groups. One repetition maximum load (1-RM) on half squat exercise and VFC measurements were determined pre- and post-training program. Both groups had improved 1-RM load after the program (15.1% in TF group and 16.4% in TF+V30 group), although this increase was changed in the same extent for the two groups and there was no difference in 1-RM load between groups pre- and post-training program. No significant difference was observed in resting VFC measurements between groups pre and post-training program, however the magnitude of the effect size was moderated (ES = 0.50-0.80) for some variables (R-R interval, standard deviation of all R-R interval - SDNN, RMSSD, log-transformed of low frequency - InLF, and log-transformed of high frequency - InHF) in TF+V30 group. It was concluded that 10 weeks of strength training program with or without the vibration platform provided similar increase in 1-RM load in both groups, and although some evidences in this study indicate that vibration can increase vagal activity analyzed by ES, in neither groups the strength training was able to change VFC significantly.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the present study, we evaluated peripheral and central auditory pathways in professional musicians (with and without hearing loss) compared to non-musicians. The goal was to verify if music exposure could affect auditory pathways as a whole. This is a prospective study that compared the results obtained between three groups (musicians with and without hearing loss and non-musicians). Thirty-two male individuals participated and they were assessed by: Immittance measurements, pure-tone air conduction thresholds at all frequencies from 0.25 to 20 kHz, Transient Evoked Otoacoustic Emissions, Auditory Brainstem Response (ABR), and Cognitive Potential. The musicians showed worse hearing thresholds in both conventional and high frequency audiometry when compared to the non-musicians; the mean amplitude of Transient Evoked Otoacoustic Emissions was smaller in the musicians group, but the mean latencies of Auditory Brainstem Response and Cognitive Potential were diminished in the musicians when compared to the non-musicians. Our findings suggest that the population of musicians is at risk for developing music-induced hearing loss. However, the electrophysiological evaluation showed that latency waves of ABR and P300 were diminished in musicians, which may suggest that the auditory training to which these musicians are exposed acts as a facilitator of the acoustic signal transmission to the cortex.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is shown that the generation of cavities in a liquid can produce usable work, which is illustrated by the stretching of a string. This work is done during the expansion of the cavity, and not with its collapse. Basic equations are presented for the movement of a device moved by the so called cavity events. A theoretical solution is also proposed, which uses polynomial functions relating the so called "excess of pressure" in the cavity and time. Evaluations of the force generated during the expansion of the cavity showed a mean peak value of about 58 N for the moving container, while measurements with the container fixed to a support showed a peak value of 476 N, considered somewhat overestimated, because high frequency oscillations seem to superpose the mean behavior. Simultaneous phenomena occurring during the cavity events are also described. Series of pictures of the experiments are presented.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents the results of research aiming to develop partial discharge detection techniques in high voltage equipment, at substation environment. Measurements of high frequency components of leakage current, at equipments' grounding conductor, were performed. This procedure was performed with the equipment energized and without disconnecting it from the system. The partial discharge generated current pulse is picked up by a high frequency CT, and is detected by an oscilloscope. The partial discharge identification was made considering previously obtained laboratory results, where partial discharges were characterized by means of its time domain signatures. This paper focuses measurements in SF6 circuit breakers. Encouraging results were obtained, showing the feasibility of detecting partial discharges in energized equipment in the laboratory and in the field, in a substation environment, using this method.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Diffusion is a common phenomenon in nature and generally is associated with a system trying to reach a local or a global equilibrium state, as a result of highly irregular individual particle motion. Therefore it is of fundamental importance in physics, chemistry and biology. Particle tracking in complex fluids can reveal important characteristics of its properties. In living cells, we coat the microbead with a peptide (RGD) that binds to integrin receptors at the plasma membrane, which connects to the CSK. This procedure is based on the hypothesis that the microsphere can move only if the structure where it is attached move as well. Then, the observed trajectory of microbeads is a probe of the cytoskeleton (CSK), which is governed by several factors, including thermal diffusion, pressure gradients, and molecular motors. The possibility of separating the trajectories into passive and active diffusion may give information about the viscoelasticity of the cell structure and molecular motors activity. And also we could analyze the motion via generalized Stokes-Einstein relation, avoiding the use of any active techniques. Usually a 12 to 16 Frames Per Second (FPS) system is used to track the microbeads in cell for about 5 minutes. Several factors make this FPS limitation: camera computer communication, light, computer speed for online analysis among others. Here we used a high quality camera and our own software, developed in C++ and Linux, to reach high FPS. Measurements were conducted with samples for 10£ and 20£ objectives. We performed sequentially images with different intervals, all with 2 ¹s exposure. The sequences of intervals are in milliseconds: 4 5 ms (maximum speed) 14, 25, 50 and 100 FPS. Our preliminary results highlight the difference between passive and active diffusion, since the passive diffusion is represented by a Gaussian in the distribution of displacements of the center of mass of individual beads between consecutive frames. However, the active process, or anomalous diffusion, shows as long tails in the distribution of displacements.