9 resultados para Hearing aid industry

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Presbycusis is a common disorder in the elderly, which causes hearing loss and may contribute to the development of some psychiatric disorders, leading to isolation clue to communication difficulties in the social environment. Objective: To identify through the WHOQOL (World Health Organization Quality of Life Questionnaire), the quality of life of hearing impaired individuals before and after hearing aid fittings. Method: We had 30 individuals with hearing loss, all over 60 years of age - patients from a Speech Therapy Clinic. The patients answered the WHOQOL questions without the use of hearing aids; and after the effective use of a sound amplification device for a period of three months they answered it again. The WHOQOL - Bref consists of 26 questions, two general quality-of-life questions and 24 associated with four aspects: physical, psychological, environmental and social relations. Results: There was a significant improvement in quality of life in general, as far as leisure activities were concerned, there were no major changes regarding the frequency of negative feelings; even after the hearing aid fitting, the patients continue to have such feelings. Conclusion: The use of hearing aids favored the overall quality of life of the individuals evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Hearing loss (HL) is defined as the complete or partial loss of hearing ability. Aims: To characterize (1) the degree of satisfaction among adult and elderly hearing aid (HA) users who were treated by a public hearing health service and (2) the relationship between satisfaction and the variables of gender, age, degree of HL, and type of HA. Method: The clinical and experimental study included the administration of the Satisfaction with Amplification in Daily Life (SADL) questionnaire to 110 patients who had used HAs for more than 3 months and were 18 years of age or older. Results: Test patients were sex-balanced (48% were women) and had a mean age of 67 years. A relatively high incidence of sensorineural moderate HL was detected in the study patients (66%) and device B was the most commonly used HA type (48%). No significant differences were evident between HA satisfaction and sex. The importance placed on services/costs and personal image varied between age groups. Correlation was evident at all levels between user satisfaction and amplification. Decreased satisfaction was observed in individuals with severe and/or profound HL. The type of HA used yielded statistically significant differences in the positive effects referring. Conclusion: No correlations were evident between the different factors proposed. HA users exhibited high levels of satisfaction in all SADL areas

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare) to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: O BAHA (Bone Ancored Hearing Aid) é um dispositivo auditivo de condução óssea que propaga o som diretamente à orelha interna, utilizado principalmente em pacientes com perda auditiva condutiva associada a atresia aural, mas atualmente também em perdas mistas e neurossensoriais. OBJETIVO: Revisar as principais indicações do BAHA, analisar os resultados audiométricos e os benefícios proporcionados aos pacientes, e compará-los com outras modalidades de tratamento além de comparar os dados da literatura com nossa casuística de 13 pacientes. MÉTODO: A pesquisa foi realizada em bases de dados abrangendo trabalhos em inglês, espanhol e português, sem limites de intervalos de anos, comparando com os resultados dos nossos 13 pacientes submetidos a esse procedimento, no período de 2000 a 2009. RESULTADOS: A maioria dos trabalhos mostrou vantagens do BAHA em comparação à cirurgia reconstrutiva, tanto pelos resultados audiológicos quanto em relação a complicações e recidiva. Os resultados pós-operatórios nos 13 pacientes operados por nossa equipe foi satisfatório e compatível com os da literatura, com fechamento do gap aéreo-ósseo em 7 pacientes e gap aéreo-ósseo de até 10 dB em 6 pacientes. Não houve complicações pós-operatórias. CONCLUSÃO: O BAHA é uma ótima opção de tratamento para pacientes com surdez condutiva bilateral, fato demonstrado pelos bons resultados audiológicos e por se tratar de um procedimento cirúrgico relativamente simples e com baixa taxa de complicações. Os estudos mais recentes vêm abordando seu uso para surdez condutiva e neurossensorial unilateral.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Hearing loss is one of the most common clinical findings in subjects with malformations of the ear. Treatment consists of surgery and/or adapt a hearing aid amplification by bone (HA VO). Early intervention is critical to auditory stimulation and development of speech and language. OBJECTIVE: To characterize the audiological profile of subjects with congenital malformation of the external ear and/or middle and evaluate the benefit and satisfaction of using HA VO. METHOD: A descriptive study, subjects with bilateral congenital malformations of the external ear and/or middle, conductive or mixed hearing loss, moderate or severe and HA VO users. Evaluation of the benefit test using sentence recognition in noise and measures of functional gain and satisfaction assessment questionnaire using international IQ - HA. RESULTS: 13 subjects were evaluated, 61% were male and 80% with moderate conductive hearing loss or severe. There was better performance in the evaluation proposal, provided with HA when compared to the condition without HA. CONCLUSION: HA VO showed advantages for the population studied and should be considered as an option for intervention. Satisfaction was confirmed by elevated scores obtained in IQ - HA.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the present days it is critical to identify the factors that contribute to the quality of the audiologic care provided. The hearing aid fitting model proposed by the Brazilian Unified Health System (SUS) implies multidisciplinary care. This leads to some relevant and current questions. OBJECTIVE: To evaluate and compare the results of the hearing aid fitting model proposed by the SUS with a more compact and streamlined care. METHOD: We conducted a prospective longitudinal study with 174 participants randomly assigned to two groups: SUS Group and Streamline Group. For both groups we assessed key areas related to hearing aid fitting through the International Outcome Inventory for Hearing Aids (IOI-HA) questionnaire, in addition to evaluating the results of Speech Recognition Index (SRI) 3 and 9 months after fitting. RESULTS: Both groups had the same improvement related to the speech recognition after nine months of AASI use, and the IOI-HA didn't show any statically significant difference on three and nine months. CONCLUSION: The two strategies of care did not differ, from the clinical point of view, as regards the hearing aid fitting results obtained upon the evaluation of patients in the short and medium term, thus changes in the current model of care should be considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: O governo brasileiro atualmente credencia cerca de 140 centros especializados para adaptações de aparelhos de amplificação sonora individual via SUS. Adaptações à distância através da internet podem permitir maior eficiência na prestação deste serviço e com maiores chances de aceitação por parte do paciente do SUS. OBJETIVOS: Descrever o caso de adaptação à distância realizado entre duas cidades, com revisão da literatura. MÉTODO: Equipamentos de informática e de tecnologia da informação, programador universal, aparelhos de amplificação sonora individual. ESTUDO DE CASO: Uma fonoaudióloga lotada num centro especializado introduziu a um centro remoto (distância de 200 km) um novo aparelho de amplificação sonora individual e seu programa de adaptação. O centro remoto assistiu a adaptação de dois pacientes em sua clínica, realizando voluntariamente a adaptação do terceiro paciente. Todo o procedimento foi realizado através da internet, contando com recursos de áudio e vídeo em todos os procedimentos. RESULTADOS: Três pacientes foram adaptados à distância. Três fonoaudiólogas receberam treinamento à distância de como adaptar aparelhos auditivos. CONCLUSÃO: Foi possível adaptar AASI à distância, além de prover treinamento e habilitar um centro remoto na adaptação de um novo aparelho de amplificação sonora individual e de seu programa de adaptação. Tal procedimento pode ser útil ao governo na condução de políticas públicas da saúde auditiva.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a eficácia da teleconsulta para a programação, verificação e adaptação do aparelho de amplificação sonora individual (AASI). MÉTODOS: Cinquenta participantes com deficiência auditiva (idades entre 39 e 88 anos), com média dos limiares audiométricos entre 30 e 68,75 dBNA, foram alocados em dois grupos (randomização estratificada), controle (n=25) e experimental (n=25), submetidos respectivamente à consulta face a face e teleconsulta síncrona com video interativo e controle remoto de aplicativos. Foram realizadas a programação e verificação do AASI (medidas com microfone sonda) e orientação dos participantes quanto ao uso e cuidados com o dispositivo. O tempo para os procedimentos foi cronometrado. Após as consultas um avaliador, cego quanto aos grupos, aplicou o teste de percepção da fala Hearing in Noise Test (HINT) Brasil. Aproximadamente um mês após as consultas, foi verificado o tempo diário de uso do AASI e administrado o questionário International Outcome Inventory for Hearing Aids (IOI-HA). RESULTADOS: Maior tempo para a programação e verificação e menor tempo para orientação foi observado para o grupo experimental. Não houve diferença entre grupos no tempo total do atendimento. A equiparação das medidas com microfone sonda aos respectivos targets de amplificação foi similar para os dois grupos. Não houve diferença entre os grupos quanto aos resultados do HINT-Brasil (silêncio e ruído), o tempo médio de uso diário do AASI e resultados do IOI-HA. CONCLUSÃO: A teleconsulta é um procedimento eficaz para a programação, verificação do AASI e orientação de usuários quando serviços face a face não estiverem disponíveis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research intended to analyze the adoption process of the green certification "Leadership in Energy and Environmental Design" (LEED) from the hotel sector establishments that has already adopted it. For its concretization it was proceeded a bibliographical research, secondary fact-gathering in journals, institutional sites and documentaries, and primary fact-gathering by means of semi structured interviews carried out with responsible people of the certified hotels and of the responsible entity of the certification in Brazil (Green Building Council Brazil). There were 21 interviewee, being 02 of the GBC Brazil and 19 of means of lodging (31% of the certified). For data analysis, it was utilized content analysis technique with the aid of ATLAS.ti software. The results permitted to identify the chronology of the processes of certification and the profile of the hotel categories that adopt the LEED program. Beyond that, the interviews enabled the discussion of the initial motivations for seeking the certification, as well the advantages and the obstacles perceived regarding its adoption.