10 resultados para Halley’s and Euler-Chebyshev’s Methods

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical guidelines advise that dentists take radiographs in children to detect caries lesions missed by visual inspection; however, due to the current low caries prevalence in most countries, we hypothesized that the adjunct methods of caries detection would not significantly improve the detection of primary molar lesions in comparison to visual inspection alone. We evaluated the performance of visual inspection, alone or in combination with radiographic and laser fluorescence pen (LFpen) methods, in detecting occlusal and approximal caries lesions in primary molars. Two examiners evaluated children who had sought dental treatment with these diagnostic strategies. The reference standard involved the temporary separation of approximal and operative interventions for occlusal surfaces. The sensitivity, specificity, accuracy and utility of diagnostic strategies were calculated. Simultaneous combined strategies increased sensitivities but decreased specificities. Furthermore, no differences were observed in accuracy and utility, parameters more influenced by caries prevalence. In conclusion, adjunct radiographic and laser fluorescence methods offer no benefits to the detection of caries in primary teeth in comparison to visual inspection alone; hence, present clinical guidelines should be re-evaluated. Copyright (C) 2012 S. Karger AG, Basel

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Measurements of hormonal concentrations by immunoassays using fluorescent tracer substance (Eu3+) are susceptible to the action of chemical agents that may cause alterations in its original structure. Our goal was to verify the effect of two types of anticoagulants in the hormone assays performed by fluorometric (FIA) or immunofluorometric (IFMA) methods. Methods Blood samples were obtained from 30 outpatients and were drawn in EDTA, sodium citrate, and serum separation Vacutainer®Blood Collection Tubes. Samples were analyzed in automatized equipment AutoDelfia™ (Perkin Elmer Brazil, Wallac, Finland) for the following hormones: Luteinizing hormone (LH), Follicle stimulating homone (FSH), prolactin (PRL), growth hormone (GH), Sex hormone binding globulin (SHBG), thyroid stimulating hormone (TSH), insulin, C peptide, total T3, total T4, free T4, estradiol, progesterone, testosterone, and cortisol. Statistical analysis was carried out by Kruskal-Wallis method and Dunn's test. Results No significant differences were seen between samples for LH, FSH, PRL and free T4. Results from GH, TSH, insulin, C peptide, SHBG, total T3, total T4, estradiol, testosterone, cortisol, and progesterone were significant different between serum and EDTA-treated samples groups. Differences were also identified between serum and sodium citrate-treated samples in the analysis for TSH, insulin, total T3, estradiol, testosterone and progesterone. Conclusions We conclude that the hormonal analysis carried through by FIA or IFMA are susceptible to the effects of anticoagulants in the biological material collected that vary depending on the type of assay.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, a total of 172 samples of minimally processed vegetables (MPV) were collected from supermarkets in the city of Campinas, Brazil. The MPV were analyzed using traditional and/or alternative methods for total aerobic mesophilic bacteria, total coliforms, Escherichia coil, coagulase positive staphylococci, Salmonella and Listeria monocytogenes. All the MPV analyzed presented populations of aerobic mesophilic microorganisms and total coliforms were >4 log(10) CFU/g and 1.0-3.4 log(10) CFU/g, respectively. E. coil was enumerated in only 10 samples out of 172 collected, while none of the 172 samples of MPV presented contamination by coagulase positive Staphylococcus (<10(1) CFU/g). Among the four methods used for detection of Salmonella in MPV (Vidas, 1,2 Test, Reveal, and Traditional), when Reveal was used a total of 29 positive samples were reported. For L monocytogenes, the four methods tested (Vidas, Vip, Reveal, and traditional) performed similarly. The presence of Salmonella and L monocytogenes in MPV was confirmed in one (watercress) and two samples (watercress and escarole), respectively. In conclusion, it has been observed that the microbiological quality of MPV commercialized in Campinas is generally satisfactory. Besides, the choice of microbiological method should be based not only on resource and time issues, but also on parameters such as sensitivity and specificity for the specific foods under ahalysis. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amniotic fluid (AF) was described as a potential source of mesenchymal stem cells (MSCs) for biomedicine purposes. Therefore, evaluation of alternative cryoprotectants and freezing protocols capable to maintain the viability and stemness of these cells after cooling is still needed. AF stem cells (AFSCs) were tested for different freezing methods and cryoprotectants. Cell viability, gene expression, surface markers, and plasticity were evaluated after thawing. AFSCs expressed undifferentiated genes Oct4 and Nanog; presented typical markers (CD29, CD44, CD90, and CD105) and were able to differentiate into mesenchymal lineages. All tested cryoprotectants preserved the features of AFSCs however, variations in cell viability were observed. In this concern, dimethyl sulfoxide (Me2SO) showed the best results. The freezing protocols tested did not promote significant changes in the AFSCs viability. Time programmed and nonprogrammed freezing methods could be used for successful AFSCs cryopreservation for 6 months. Although tested cryoprotectants maintained undifferentiated gene expression, typical markers, and plasticity of AFSCs, only Me2SO and glycerol presented workable viability ratios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article analyzes the role that has been attributed to grammar throughout the history of foreign language teaching, with special emphasis on methods and approaches of the twentieth century. In order to support our argument, we discuss the notion of grammar by proposing a conceptual continuum that includes the main meanings of the term which are relevant to our research. We address as well the issue of "pedagogical grammar" and consider the position of grammar in the different approaches of the "era of the methods" and the current "post-method condition" in the field of language teaching and learning. The findings presented at the end of the text consist of recognizing the central role that grammar has played throughout the history of the methods and approaches, where grammar has always been present by the definition of the contents' progression. The rationale that we propose for this is the recognition of the fact that the dissociation between what is said and how it is said can not be more than theoretical and, thus, artificial.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Morphometric methods permit identification of insect species and are an aid for taxonomy. Quantitative wing traits were used to identify male euglossine bees. Landmark- and outline-based methods have been primarily used independently. Here, we combine the two methods using five Euglossa. Landmark-based methods correctly classified 84% and outline-based 77%, but an integrated analysis correctly classified 91% of samples. Some species presented significantly high reclassification percentages when only wing cell contour was considered, and correct identification of specimens with damaged wings was also obtained using this methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The estimation of reference evapotranspiration (ETo), used in water balance, allows to determine soil water content, assisting on irrigation management. The present study aimed to compare simple ETo estimating methods with the Penman-Monteith (FAO), in the folowing time scales: daily, 5, 10, 15 and 30 days and monthly in the counties of Frederico Westphalen and Palmeira das Missoes, in the Rio Grande do Sul state, Brazil. The methods tested had their efficiency improved by increasing the time scale of analysis, keeping the same performance for both locations. The highest and lowest ETo values occurred in December and June, respectively. Most methods underestimated ETo. For any of the time scales Makking and Radiaton FAO24 methods can replace the Penman-Monteith for estimating ETo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seaweeds are photosynthetic organisms important to their ecosystem and constitute a source of compounds with several different applications in the pharmaceutical, cosmetic and biotechnology industries, such as triacylglycerols, which can be converted to fatty acid methyl esters that make up biodiesel, an alternative source of fuel applied in economic important areas. This study evaluates the fatty acid profiles and concentrations of three Brazilian seaweed species, Hypnea musciformis (Wulfen) J.V. Lamouroux (Rhodophya), Sargassum cymosum C. Agardh (Heterokontophyta), and Ulva lactuca L. (Chlorophyta), comparing three extraction methods (Bligh & Dyer - B&D; AOAC Official Methods - AOM; and extraction with methanol and ultrasound - EMU) and two transesterification methods (7% BF3 in methanol - BF3; and 5% HCl in methanol - HCl). The fatty acid contents of the three species of seaweeds were significantly different when extracted and transesterified by the different methods. Moreover, the best method for one species was not the same for the other species. The best extraction and transesterification methods for H. musciformis, S. cymosum and U. lactuca were, respectively, AOM-HCl, B&D-BF3 and B&D-BF3/B&D-HCl. These results point to a matrix effect and the method used for the analysis of the fatty acid content of different organisms should be selected carefully.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate accuracy, precision and robustness of two methods to obtain silage samples, in comparison with extraction of liquor by manual screw-press. Wet brewery residue alone or combined with soybean hulls and citrus pulp were ensiled in laboratory silos. Liquor was extracted by a manual screw-press and a 2-mL aliquot was fixed with 0.4 mL formic acid. Two 10-g silage samples from each silo were diluted in 20 mL deionized water or 17% formic acid solution (alternative methods). Aliquots obtained by the three methods were used to determine the silage contents of fermentation end-products. The accuracy of the alternative methods was evaluated by comparing mean bias of estimates obtained by manual screw-press and by alternative methods, whereas precision was assessed by the root mean square prediction error and the residual error. Robustness was determined by studying the interaction between bias and chemical components, pH, in vitro dry matter digestibility (IVDMD) and buffer capacity. The 17% formic acid method was more accurate for estimating acetic, butyric and lactic acids, although it resulted in low overestimates of propionic acid and underestimates of ethanol. The deionized water method overestimated acetic and propionic acids and slightly underestimated ethanol. The 17% formic acid method was more precise than deionized water for estimating all organic acids and ethanol. The robustness of each method with respect to variation in the silage chemical composition, IVDMD and pH is dependent on the fermentation end-product at evaluation. The robustness of the alternative methods seems to be critical at the determination of lactic acid and ethanol contents.