13 resultados para H 980 T278t
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Objective: The aim of this study was to evaluate the microhardness of radicular dentin after treatment with 980-nm diode laser and different irrigant solutions. Background data: There are few reports of the consequences of diode laser irradiation emitted at 980 nm on the mechanical properties of dentin. Methods: Seventy-two single canal, human canines with complete root formation were randomly distributed among three groups (n = 24), according to the irrigant solution used in the biomechanical preparation: distilled water; 1% NaOCl; and, 1% NaOCl + 17% EDTA. These groups subsequently were divided into three subgroups (n = 8), according to the diode laser parameter: no irradiation (control); 1.5W/100 Hz; and 3.0 W/100 Hz. Laser was applied with helicoidal movements for 20 sec. Roots were sectioned in slices and the fragment corresponding to the middle third was submitted to the microhardness test (KHN) at depths of 30, 90, 150, and 300 mu m. Results: ANOVA and Tukey tests showed that the microhardness of the groups irradiated with 1.5 W/100 Hz (49.7 +/- 11.2) and 3.0W/100 Hz (50.6 +/- 11.9) were statistically similar to each other (p > 0.05) and different (p < 0.05) from the non-irradiated group (45.0 +/- 9.7). Higher microhardness values were obtained at 150 mu m (49.2 +/- 11.0) and 300 mu m (52.3 +/- 11.3) which were similar among themselves and different (p < 0.05) only at the depth of 30 mu m (44.4 +/- 10.5). No differences were found among the irrigant solutions (p > 0.05). Conclusions: The microhardness of the radicular dentin increased after irradiation with 980-nm diode laser.
Resumo:
This work reports on the infrared-to-visible CW frequency upconversion from planar waveguides based on Er3+-Yb3+-doped 100-xSiO(2)-xTa(2)O(5) obtained by a sol-gel process and deposited onto a SiO2-Si substrate by dip-coating. Surface morphology and optical parameters of the planar waveguides were analyzed by atomic force microscopy and the m-line technique. The influence of the composition on the electronic properties of the glass-ceramic films was followed by the band gap ranging from 4.35 to 4.51 eV upon modification of the Ta2O5 content. Intense green and red emissions were detected from the upconversion process for all the samples after excitation at 980 nm. The relative intensities of the emission bands around 550 nm and 665 nm, assigned to the H-2(11/2) -> I-4(15/2), S-4(3/2) -> I-4(15/2), and F-4(9/2) -> I-4(15/2) transitions, depended on the tantalum oxide content and the power of the laser source at 980 nm. The upconversion dynamics were investigated as a function of the Ta2O5 content and the number of photons involved in each emission process. Based on the upconversion emission spectra and 1931CIE chromaticity diagram, it is shown that color can be tailored by composition and pump power. The glass ceramic films are attractive materials for application in upconversion lasers and near infrared-to-visible upconverters in solar cells.
Resumo:
We report the first observation of photoluminescence enhancement in Er3+ doped GeO2-Bi2O3 glasses containing silicon nanocrystals (Si-NCs) excited by a laser operating at 980 nm. The growth of approximate to 200% in the intensity of the Er3+ transition S-4(3/2) -> I-4(15/2) (545 nm) and of approximate to 100% for transitions H-2(11/2) -> I-4(15/2) (525 nm), F-4(9/2) -> I-4(15/2) (660 nm), and I-4(5/2) -> I-4(13/2) (1530 nm) was observed in comparison with a reference sample that does not contain Si-NCs. The results open a new road for obtaining efficient Stokes and anti-Stokes emissions in germanate composites doped with rare-earth ions.
Resumo:
The influence of silver nanoparticles (NPs) on the frequency upconversion luminescence in Er3+ doped TeO2-WO3-Bi2O3 glasses is reported. The effect of the NPs on the Er3+ luminescence was controlled by appropriate heat-treatment of the samples. Enhancement up to 700% was obtained for the upconverted emissions at 527, 550, and 660 nm, when a laser at 980 nm is used for excitation. Since the laser frequency is far from the NPs surface plasmon resonance frequency, the luminescence enhancement is attributed to the local field increase in the proximity of the NPs and not to energy transfer from the NPs to the emitters as is usually reported. This is the first time that the effect is investigated for tellurite-tungstate-bismutate glasses and the enhancement observed is the largest reported for a tellurium oxide based glass. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4754468]
Resumo:
Purpose: To examine the accuracy of a screening programme for potentially malignant disorders of the oral mucosa by visual inspection in primary health care. Materials and Methods: The study was based on secondary data from the Primary Care Information System maintained by seven units of family health in Sao Paulo City managed by a non-governmental agency. The reference population was composed of 15,072 residents 50 years old or more of both genders. The study population comprised 2,980 individuals. During screening in community settings, the oral mucosa was examined by trained dentists and distributed into two categories: (a) screen negative (b) screen positive. All participants underwent comprehensive clinical exams by a general dental practitioner supervised by a specialist. Individual records were grouped in a working dataset. Point and 95% confidence interval estimates were calculated regarding measures of sensitivity (Se), specificity (Sp) and positive and negative predictive values (PPV and NPV, respectively). Results: 18.0% of the population was considered screen positive. A total of 133 lesions (4.5%) were identified and 8 cases of oral cancer were confirmed, which corresponded to a prevalence rate of 27 cases in 10,000 people, a much higher rate than expected. The measures found were Se: 91.7% (85.3-95.6), Sp: 85.4% (84.1-86.7), PPV: 22.7% (19.3-26.5), NPV: 99.5% (99.2-99.8). The visual screen presented high accuracy. Conclusion: The test presented high sensibility and specificity values. From a public health point of view, the high accuracy levels showed the importance of oral health teams on family health strategy for more comprehensive primary care. Targeting risk groups and delegating the screening to community health agents may improve PPV and coverage.
Resumo:
This manuscript reports the first example of up-conversion properties involving Yb3+ and Tb3+ ions in five isostructural Lanthanide-Organic Frameworks (LnOFs), herein designated as UCMarker-1 to UCMarker-5, respectively, and their application as optical probes for the identification of gunshot residues (GSRs) and the ammunition encryption procedure. The excitation of the Yb3+2 F-7/2 <-> F-2(5/2) transition (980 nm) at room temperature leads to visible up-conversion (UC) emission of Tb3+ D-5(4) -> F-7(J). The GSR and lead-free primer residues are easily identified upon UV radiation (lambda = 254 nm). These results prove that the exploration of LnOFs to identify GSR is attractive for the identification of ammunition origins or caliber recognition.
Resumo:
The Er3+-Yb3+ co-doped MgAl2O4 phosphor powders have been prepared by the combustion method. The phosphor powders are well characterized by X-ray diffraction (XRD) and energy dispersive (EDX) techniques. The absorption spectrum of Er3+/Er3+-Yb3+ doped/co-doped phosphor powder has been recorded in the UV-Vis-NIR region of the electro-magnetic spectrum. The evidence for indirect pumping under 980 nm excitation of Er3+ from Yb3+ was observed in the MgAl2O4 matrix material. Electron spin resonance (ESR) studies were carried out to identify the defect centres responsible for the thermally stimulated luminescence (TSL) process in MgAl2O4:Er3+ phosphor. Three defect centres were identified in irradiated phosphor by ESR measurements which were carried out at room temperature and these were assigned to an O- ion and F+ centres. O- ion (hole centre) appears to correlate with the low temperature TSL peak at 210 A degrees C and one of the F+ centres (electron centre) is related to the high temperature peak at 460 A degrees C.
Resumo:
Environmental tobacco smoke (ETS) leads to the death of 600,000 nonsmokers annually and is associated with disturbances in antioxidant enzyme capacity in the adult rodent brain. However, little is known regarding the influence of ETS on brain development. The aim of this study was to determine levels of malonaldehyde (MDA) and 3-nitrotyrosine (3-NT), as well as enzymatic antioxidant activities of glutathione peroxidase (GPx), glutathione reductase (GR), glutathione S-transferase (GST), and superoxide dismutase (SOD), in distinct brain structures. BALB/c mice were exposed to ETS twice daily for 1 h from postnatal day 5 through postnatal day 18. Acute exposure was performed for 1 h on postnatal day 18. Mice were euthanized either immediately (0) or 3 h after the last exposure. Immediately after an acute exposure there were higher GR and GST activities and MDA levels in the hippocampus, higher GPx and SOD activities in the prefrontal cortex, and higher GST activity and MDA levels in the striatum and cerebellum. Three hours later there was an increase in SOD activity and MDA levels in the hippocampus and a decrease in the activity of all enzymes in the prefrontal cortex. Immediately after final repeated exposure there were elevated levels of GST and GR activity and decreased GPx activity in the hippocampus. Moreover, a rise was found in GPx and GST activities in the prefrontal cortex and increased GST and GPx activity in the striatum and cerebellum, respectively. After 3 h the prefrontal cortex showed elevated GR and GST activities, and the striatum displayed enhanced GST activity. Data showed that enzymatic antioxidant system in the central nervous system responds to ETS differently in different regions of the brain and that a form of adaptation occurs after several days of exposure.
Resumo:
Isotibolone is frequently found as an impurity in tibolone, a drug used for hormone reposition of post-menopause women, due to some inadequate tibolone synthesis or as a result of degradation during drug storage. The presence of isotibolone impurities should be detected and quantified in active pharmaceutical ingredient products of tibolone before its use in the manufacturing of medicaments. The X-ray powder diffraction technique offers the possibility of quantifying isotibolone amounts at different stages of drug production and storage, from the chemical synthesis to the final formulation. In the course of a study involving the quantitative analysis of isotibolone by X-ray powder diffraction, the authors determined the structure of the title compound using a recently developed approach (A. Gomez and S. Kycia, J. Appl. Crystallogr. 2011, 44, 708-713). The structure is monoclinic, space group P2(1) (4), with unit cell parameters a = 6.80704(7) angstrom, b = 20.73858(18) angstrom, c = 6.44900(6) angstrom, beta = 76.4302(5)degrees, V = 884.980(15) angstrom(3) and two molecules per unit cell (Z = 2). The molecules are hydrogen bonded in the ab plane forming layers that are held together in the crystal by van der Waals interactions along the c-axis.
Resumo:
OBJETIVOS: trata-se de ensaio clínico randomizado com o objetivo de avaliar a auriculoterapia, para diminuição de níveis de estresse, em 75 profissionais de enfermagem de um hospital e analisar os principais domínios de coping que se modificaram após o tratamento. METODOLOGIA: os sujeitos foram divididos em grupos (controle, agulhas, sementes), receberam 8 sessões nos pontos Shenmen, rim e tronco cerebral. O grupo controle não recebeu nenhuma intervenção. RESULTADOS: constataram-se diferenças significativas pela ANOVA, para níveis de estresse entre o grupo agulha/controle na terceira e quarta avaliações, segundo escores de estresse da Lista de Sintoma de Stress de Vasconcelos. Para o Inventário de Folkman e Lazarus, obteve-se diferença estatística para o domínio afastamento entre os grupos agulha/controle, após tratamento; e, na análise dentro do mesmo grupo, obtiveram-se diferenças significativas para o domínio confronto, na quarta avaliação entre grupos agulha/controle e para suporte social, na terceira avaliação para os grupos agulha/semente. CONCLUSÕES: a auriculoterapia com agulhas diminuiu os níveis de estresse significativamente e houve diminuição da utilização dos domínios afastamento, confronto e suporte social para os grupos de intervenção, após o tratamento, sugerindo que a auriculoterapia tanto com agulhas quanto com sementes pode produzir impacto positivo para melhorar a estratégia de coping na equipe de enfermagem. Mais estudos, porém, fazem-se necessários para que se possa conhecer o alcance da técnica.
Resumo:
Foi realizada uma análise espacial da ocorrência de leptospirose humana e canina na Supervisão de Vigilância em Saúde do Butantã, situada no município de São Paulo, no ano de 2007, associada a variáveis ambientais de risco, tais como: focos de enchente e áreas de desratização. Foram encontrados aglomerados espaciais de pontos de alagamentos em 12 setores censitários e de casos de leptospirose humana em quatro setores censitários, sem correlação entre ambos. Não foram encontrados agrupamentos de casos em cães, possivelmente devido à subnotificação. As proporções casos humanos de leptospirose : população humana dentro e fora da área de desratização foram 7:199.600 e 9:257.980, respectivamente. Conclui-se que medidas de controle de roedores como a desratização foram responsáveis pela minimização dos efeitos dos fatores de risco para a transmissão de leptospirose para humanos.
Resumo:
Aim: We evaluated the effectiveness of high-frequency transcutaneous electrical nerve stimulation (TENS) as a pain relief resource for primiparous puerpere who had experienced natural childbirth with an episiotomy. Methods: A controlled, randomized clinical study was conducted in a Brazilian maternity ward. Forty puerpere were randomly divided into two groups: TENS high frequency and a no treatment control group. Post-episiotomy pain was assessed in the resting and sitting positions and during ambulation. An 11-point numeric rating scale was performed in three separate evaluations (at the beginning of the study, after 60 min and after 120 min). The McGill pain questionnaire was employed at the beginning and 60 min later. TENS with 100 Hz frequency and 75 mu s pulse for 60 min was employed without causing any pain. Four electrodes ware placed in parallel near the episiotomy site, in the area of the pudendal and genitofemoral nerves. Results: An 11-point numeric rating scale and McGill pain questionnaire showed a significant statistical difference in pain reduction in the TENS group, while the control group showed no alteration in the level of discomfort. Hence, high-frequency TENS treatment significantly reduced pain intensity immediately after its use and 60 min later. Conclusion: TENS is a safe and viable non-pharmacological analgesic resource to be employed for pain relief post-episiotomy. The routine use of TENS post-episiotomy is recommended.
Resumo:
Vigas são elementos estruturais encontrados na maioria das construções civis. Dentre os materiais de engenharia, destaca-se a madeira, por ter resistência mecânica satisfatória aliada a baixa densidade. A madeira roliça apresenta-se como boa solução na confecção de vigas, uma vez que não precisa ser processada, como é o caso da madeira serrada. O projeto de elementos estruturais de madeira requer o conhecimento de suas propriedades físicas e mecânicas, obtidas segundo as premissas de documentos normativos. Em se tratando da madeira roliça, os documentos normativos nacionais que tratam da determinação das propriedades de resistência e rigidez estão vigentes há mais de vinte anos sem revisão técnica. De forma geral, tanto as normas nacionais como as internacionais idealizam geometria troncocônica para as peças roliças de madeira, implicando equações simplificadas incapazes de prever a influência das irregularidades da forma na determinação do módulo de elasticidade longitudinal. Este trabalho objetiva avaliar a influência das irregularidades da geometria em peças roliças de madeira Corymbia citriodora e Pinus caribaea no cálculo do módulo de elasticidade longitudinal. Para tanto, utilizou-se do ensaio de flexão estática a três pontos, considerando também um modelo matemático simplificado, assumindo seção circular constante para a forma do elemento. As irregularidades das peças são consideradas nos modelos numéricos, constituídos de elementos finitos de barra e tridimensionais. Os resultados encontrados revelam equivalência estatística entre os módulos de elasticidade para ambas as formas de cálculo, indicando ser plausível a consideração de seção circular constante para as peças de madeira aqui avaliadas.