2 resultados para H(2)LASSBIO-1064

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Complexes [Cu(2AcPh)Cl]center dot 2H(2)O (1), [Cu(2AcpClPh)Cl]center dot 2H(2)O (2), [Cu(2AcpNO(2)Ph)Cl] (3), [Cu(2BzPh)Cl] (4). [Cu(2BzpClPh)Cl] (5) and [Cu(2BzpNO(2)Ph)Cl] (6) were obtained with 2-acetylpyridine-phenylhydrazone (H2AcPh), 2-acetylpyridine-para-chloro-phenylhydrazone (H2AcpClPh), 2-acetylpyridine-para-nitro-phenylhydrazone (H2AcpNO(2)Ph), 2-benzoylpyridine-phenylhydrazone (H2BzPh), 2-benzoylpyridine-para-chloro-phenylhydrazone (H2BzpClPh) and 2-benzoylpyridine-para-nitro-phenylhydrazone (H2BzpNO(2)Ph). The hydrazones showed poor antibacterial effect against Staphylococcus aureus, Enterococcus faecalis and Pseudomonas aeruginosa but demonstrated significant antifungal activity against Candida albicans. Upon coordination to copper(II) the antibacterial and antifungal activities appreciably increased. H2AcpClPh, H2BzpClPh and their copper(II) complexes (2) and (5), respectively, were as active as fluconazole against C. albicans. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bertuzzi, R, Bueno, S, Pasqua, LA, Acquesta, FM, Batista, MB, Roschel, H, Kiss, MAPDM, Serrao, JC, Tricoli, V, and Ugrinowitsch, C. Bioenergetics and neuromuscular determinants of the time to exhaustion at velocity corresponding to (V) over dotO(2)max in recreational long-distance runners. J Strength Cond Res 26(8): 2096-2102, 2012-The purpose of this study was to investigate the main bioenergetics and neuromuscular determinants of the time to exhaustion (T-lim) at the velocity corresponding to maximal oxygen uptake in recreational long-distance runners. Twenty runners performed the following tests on 5 different days: (a) maximal incremental treadmill test, (b) 2 submaximal tests to determine running economy and vertical stiffness, (c) exhaustive test to measured the T-lim, (d) maximum dynamic strength test, and (e) muscle power production test. Aerobic and anaerobic energy contributions during the T-lim test were also estimated. The stepwise multiple regression method selected 3 independent variables to explain T-lim variance. Total energy production explained 84.1% of the shared variance (p = 0.001), whereas peak oxygen uptake ((V) over dotO(2)peak) measured during T-lim and lower limb muscle power ability accounted for the additional 10% of the shared variance (p = 0.014). These data suggest that the total energy production, (V) over dotO(2)peak, and lower limb muscle power ability are the main physiological and neuromuscular determinants of T-lim in recreational long-distance runners.