3 resultados para Gymnasium Martins-Katharineum (Braunschweig, Germany)
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The Diptera collection of the Natural History Museum Berlin holds one of the most important collections of Neriidae. In this paper, the type specimens (holotypes, lectotypes, paratypes, paralectotypes, syntypes) of this historical collection are listed. 28 species-group taxa are dealt with. A lectotype designation is made for the species Brachantichir purpusianus Enderlein, 1922 in order to fix the identity of the name. Holotypes are recognized by monotypy of the species Chaetomeristes bullatus Enderlein, 1922; Chaetomeristes peruanus Enderlein, 1922; Derocephalus angusticollis Enderlein, 1922; Glyphidops limbatus Enderlein, 1922; Longina abdominalis Wiedemann, 1830; Loxozus clavicornis Enderlein, 1922; Oncopsia mexicana Enderlein, 1922; Paranerius fibulatus Enderlein, 1922; Telostylinus dahli Enderlein, 1922; Telostylus latibrachium Enderlein, 1922; and Telostylinus luridus Enderlein, 1922. Syntypes are labelled and listed for Brachantichir robusta Enderlein, 1922; Nerius terebratus Enderlein, 1922; Odontoloxozus punctulatus Enderlein, 1922; Telostylinus apicalis Enderlein, 1922; Telostylinus obscuratus Enderlein, 1922; and Telostylinus ornatipennis Enderlein, 1922. The account concludes with geographic and taxonomic summaries; an appendix listing the abbreviations, localities, and collectors cited in the text; and a bibliography. ((c) 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
Resumo:
Estimators of home-range size require a large number of observations for estimation and sparse data typical of tropical studies often prohibit the use of such estimators. An alternative may be use of distance metrics as indexes of home range. However, tests of correlation between distance metrics and home-range estimators only exist for North American rodents. We evaluated the suitability of 3 distance metrics (mean distance between successive captures [SD], observed range length [ORL], and mean distance between all capture points [AD]) as indexes for home range for 2 Brazilian Atlantic forest rodents, Akodon montensis (montane grass mouse) and Delomys sublineatus (pallid Atlantic forest rat). Further, we investigated the robustness of distance metrics to low numbers of individuals and captures per individual. We observed a strong correlation between distance metrics and the home-range estimator. None of the metrics was influenced by the number of individuals. ORL presented a strong dependence on the number of captures per individual. Accuracy of SD and AD was not dependent on number of captures per individual, but precision of both metrics was low with numbers of captures below 10. We recommend the use of SD and AD instead of ORL and use of caution in interpretation of results based on trapping data with low captures per individual.
Resumo:
Objetivo: Estabelecer um padrão de crescimento tumoral (volume) em ratos Wistar submetidos ao modelo C6 de glioblastoma multiforme por meio de imagens de ressonância magnética para posterior verificação de redução de volume tumoral com a terapia de magnetohipertermia. Métodos: Para o modelo C6, utilizamos ratos Wistar, machos, jovens, pesando entre 250 e 300 g. Após anestesiados (cetamina 55 mg/kg e xilazina 11 mg/kg) foram injetadas estereotaxicamente células tumorigênicas linhagem C6 suspensas em meio de cultura (105 células em 10 µL) no córtex frontal direito (coordenadas a partir do bregma: anteroposterior = 2,0 mm; látero-lateral = 3,0 mm; profundidade = 2,5 mm) com uma seringa Hamilton. No Grupo Controle, houve a injeção do meio de cultura sem as células. Posteriormente, foram feitas imagens mediante a técnica de imagem por ressonância magnética em 14, 21 e 28 dias após a injeção em um escâner de imagem por ressonância magnética 2.0 T (Bruker BioSpec, Germany). Para o exame, os animais foram anestesiados com cetamina 55 mg/kg e xilazina 11 mg/kg. Multifatias coronais foram adquiridas utilizando uma sequência spin-echo padrão com os seguintes parâmetros: TR/TE = 4,000 ms/67,1 ms, FOV = 3,50, Matrix 192, slice thickness = 0,4 mm e slice separation = 0 mm. Resultados: A análise das imagens de ressonância magnética do tumor possibilitou a clara visualização da massa tumoral, sendo possível ainda estabelecer parâmetros de volume tumoral nos diferentes dias analisados. O volume de 14 dias após a indução do foi de 13,7 ± 2,5 mm3 . Aos 21 dias, o volume alcançado foi de 31,7 ± 6,5 mm3 e, aos 28 dias, a massa tumoral atingiu 122,1 ± 11,8 mm3 . Conclusão: Estes resultados mostraram a possiblidade de avaliação do volume tumoral no modelo C6 em ratos, o que possibilitará, no futuro, a aplicação da terapia de magnetohipertermia bem como verificação de seus resultados.