6 resultados para General properties of QCD
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
We study general properties of the Landau-gauge Gribov ghost form factor sigma(p(2)) for SU(N-c) Yang-Mills theories in the d-dimensional case. We find a qualitatively different behavior for d = 3, 4 with respect to the d = 2 case. In particular, considering any (sufficiently regular) gluon propagator D(p(2)) and the one-loop-corrected ghost propagator, we prove in the 2d case that the function sigma(p(2)) blows up in the infrared limit p -> 0 as -D(0) ln(p(2)). Thus, for d = 2, the no-pole condition sigma(p(2)) < 1 (for p(2) > 0) can be satisfied only if the gluon propagator vanishes at zero momentum, that is, D(0) = 0. On the contrary, in d = 3 and 4, sigma(p(2)) is finite also if D(0) > 0. The same results are obtained by evaluating the ghost propagator G(p(2)) explicitly at one loop, using fitting forms for D(p(2)) that describe well the numerical data of the gluon propagator in two, three and four space-time dimensions in the SU(2) case. These evaluations also show that, if one considers the coupling constant g(2) as a free parameter, the ghost propagator admits a one-parameter family of behaviors (labeled by g(2)), in agreement with previous works by Boucaud et al. In this case the condition sigma(0) <= 1 implies g(2) <= g(c)(2), where g(c)(2) is a "critical" value. Moreover, a freelike ghost propagator in the infrared limit is obtained for any value of g(2) smaller than g(c)(2), while for g(2) = g(c)(2) one finds an infrared-enhanced ghost propagator. Finally, we analyze the Dyson-Schwinger equation for sigma(p(2)) and show that, for infrared-finite ghost-gluon vertices, one can bound the ghost form factor sigma(p(2)). Using these bounds we find again that only in the d = 2 case does one need to impose D(0) = 0 in order to satisfy the no-pole condition. The d = 2 result is also supported by an analysis of the Dyson-Schwinger equation using a spectral representation for the ghost propagator. Thus, if the no-pole condition is imposed, solving the d = 2 Dyson-Schwinger equations cannot lead to a massive behavior for the gluon propagator. These results apply to any Gribov copy inside the so-called first Gribov horizon; i.e., the 2d result D(0) = 0 is not affected by Gribov noise. These findings are also in agreement with lattice data.
Resumo:
A new betadiketonate ligand displaying a trimethoxysilyl group as grafting function and a diketone moiety as complexing site (TTA-Si = 4,4,4-trifluoro-2-(3-trimethoxysilyl)propyl)-1-3-butanedione (C4H3S)COCH[(CH2)(3)Si(OCH3)(3)]COCF3) and its highly luminescent europium(III) complex [Eu(TTA-Si)(3)] have been synthesized and fully characterized. Luminescent silica-based hybrids have been prepared as well with this new complex grafted on the surface of dense silica nanoparticles (28 +/- 3 nm) or on mesoporous silica particles. The covalent bonding of Eu(TTA-Si)(3) inside the core of uniform silica nanoparticles (40 +/- 5 nm) was also achieved. Luminescence properties are discussed in relation to the europium chemical environment involved in each of the three hybrids. The general methodology proposed allowed high grafting ratios and overcame chelate release and tendency to agglomeration, and it could be applied to any silica matrix (in the core or at the surface, nanosized or not, dense or mesoporous) and therefore numerous applications such as luminescent markers and luminophors could be foreseen.
Resumo:
Myofibril proteins have excellent filmogenic properties. The objective of this article was to study the effect of the thermal treatment, of the pH and of the plasticizer concentration (Cp) of the filmogenic solution (FS), using over some physical properties of edible films, using a surface and response methodology (SRM). Films were made of lyophilized myofibril proteins (LMP) extracted from bovine muscle, employing the technique of solubility obtained from diluted saline solutions. The films were elaborated from FS containing 1 g of LMP/100g of FS and from Cp of 50 g to 79 g of glycerin/100 g of LMP. The LMP was dispersed in water under moderate agitation, and the pH was kept at 2.5-3.5 with the use of acetic acid. The FS were submitted to thermal treatment at different temperatures for 45 minutes. Films were dried in ventilated oven at 37 degrees C/18hr, conditioned at 75% of relative humidity at 25 degrees C/48 hr before analysis of: mechanical properties by puncture test; apparent opacity by spectrophotometer; solubility by immersion in water; and water vapor permeability by the gravimetric method. In general, films showed good appearance, translucent, easily handled and touchable, except for the films formed with pH 2.5 and at a low temperature (35 degrees C), with a medium thickness of 0.400 +/- 0.005 mm. The pH of the FS significantly affected all the physical properties under study. The temperature of the thermal treatment of the FS greatly affected the force at the rupture, solubility and water vapor permeability. This treatment can promote intermolecular interactions through the formation of disulphide bonds; however a very intense treatment can reverse this effect by irreversible structural alterations in the proteins. The glycerol concentration affected considerably all the properties under study, with the exception of the apparent opacity. Plasticizer increases the mobility of macromolecules with consequences in all physical properties.
Resumo:
Aim. The aim of this study was to evaluate the internal reliability and validity of the BrazilianPortuguese version of Duke Anticoagulation Satisfaction Scale (DASS) among cardiovascular patients. Background. Oral anticoagulation is widely used to prevent and treat thromboembolic events in several conditions, especially in cardiovascular diseases; however, this therapy can induce dissatisfaction and reduce the quality of life. Design. Methodological and cross-sectional research design. Methods. The cultural adaptation of the DASS included the translation and back-translation, discussions with healthcare professionals and patients to ensure conceptual equivalence, semantic evaluation and instrument pretest. The BrazilianPortuguese version of the DASS was tested among subjects followed in a university hospital anticoagulation outpatient clinic. The psychometric properties were assessed by construct validity (convergent, known groups and dimensionality) and internal consistency/reliability (Cronbachs alpha). Results. A total of 180 subjects under oral anticoagulation formed the baseline validation population. DASS total score and SF-36 domain correlations were moderate for General health (r = -0.47, p < 0.01), Vitality (r = -0.44, p < 0.01) and Mental health (r = -0.42, p < 0.01) (convergent). Age and length on oral anticoagulation therapy (in years) were weakly correlated with total DASS score and most of the subscales, except Limitation (r = -0.375, p < 0.01) (Known groups). The Cronbachs alpha coefficient was 0.79 for the total scale, and it ranged from 0.76 (hassles and burdens)0.46 (psychological impact) among the domains, confirming the internal consistency reliability. Conclusions. The BrazilianPortuguese version of the DASS has shown levels of reliability and validity comparable with the original English version. Relevance to clinical practice. Healthcare practitioners and researchers need internationally validated measurement tools to compare outcomes of interventions in clinical management and research tools in oral anticoagulation therapy.
Resumo:
Abstract Background Most of the instruments available to measure the oral health-related quality of life (OHRQoL) in paediatric populations focus on older children, whereas parental reports are used for very young children. The scale of oral health outcomes for 5-year-old children (SOHO-5) assesses the OHRQoL of very young children through self-reports and parental proxy reports. We aimed to cross-culturally adapt the SOHO-5 to the Brazilian Portuguese language and to assess its reliability and validity. Findings We tested the quality of the cross-cultural adaptation in 2 pilot studies with 40 children aged 5–6 years and their parents. The measurement was tested for reliability and validity on 193 children that attended the paediatric dental screening program at the University of São Paulo. The children were also clinically examined for dental caries. The internal consistency was demonstrated by a Cronbach's alpha coefficient of 0.90 for the children’s self-reports and 0.77 for the parental proxy reports. The test-retest reliability results, which were based on repeated administrations on 159 children, were excellent; the intraclass correlation coefficient was 0.98 for parental and 0.92 for child reports. In general, the construct validity was satisfactory and demonstrated consistent and strong associations between the SOHO-5 and different subjective global ratings of oral health, perceived dental treatment need and overall well-being in both the parental and children’s versions (p < 0.001). The SOHO-5 was also able to clearly discriminate between children with and without a history of dental caries (mean scores: 5.8 and 1.1, respectively; p < 0.001). Conclusion The present study demonstrated that the SOHO-5 exhibits satisfactory psychometric properties and is applicable to 5- to 6-year-old children in Brazil.
Resumo:
OBJECTIVE: To review the psychometric properties of the Beck Depression Inventory-II (BDI-II) as a self-report measure of depression in a variety of settings and populations. METHODS: Relevant studies of the BDI-II were retrieved through a search of electronic databases, a hand search, and contact with authors. Retained studies (k = 118) were allocated into three groups: non-clinical, psychiatric/institutionalized, and medical samples. RESULTS: The internal consistency was described as around 0.9 and the retest reliability ranged from 0.73 to 0.96. The correlation between BDI-II and the Beck Depression Inventory (BDI-I) was high and substantial overlap with measures of depression and anxiety was reported. The criterion-based validity showed good sensitivity and specificity for detecting depression in comparison to the adopted gold standard. However, the cutoff score to screen for depression varied according to the type of sample. Factor analysis showed a robust dimension of general depression composed by two constructs: cognitive-affective and somatic-vegetative. CONCLUSIONS: The BDI-II is a relevant psychometric instrument, showing high reliability, capacity to discriminate between depressed and non-depressed subjects, and improved concurrent, content, and structural validity. Based on available psychometric evidence, the BDI-II can be viewed as a cost-effective questionnaire for measuring the severity of depression, with broad applicability for research and clinical practice worldwide.