3 resultados para Gebhardt, Ihno
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
A thin-layer electrochemical flow cell coupled to capillary electrophoresis with contactless conductivity detection (EC-CE-(CD)-D-4) was applied for the first time to the derivatization and quantification of neutral species using aliphatic alcohols as model compounds. The simultaneous electrooxidation of four alcohols (ethanol, 1-propanol, 1-butanol, and 1-pentanol) to the corresponding carboxylates was carried out on a platinum working electrode in acid medium. The derivatization step required 1 min at 1.6 V vs. Ag/AgCl under stopped flow conditions, which was preceded by a 10 s activation at 0 V. The solution close to the electrode surface was then hydrodynamically injected into the capillary, and a 2.5 min electrophoretic separation was carried out. The fully automated flow system operated at a frequency of 12 analyses per hour. Simultaneous determination of the four alcohols presented detection limits of about 5 x 10(-5) mol As a practical application with a complex matrix, ethanol concentrations were determined in diluted pale lager beer and in nonalcoholic beer. No statistically significant difference was observed between the EC-CE-(CD)-D-4 and gas chromatography with flame ionization detection (GC-FID) results for these samples. The derivatization efficiency remained constant over several hours of continuous operation with lager beer samples (n = 40).
Resumo:
Background: Heart failure (HF) is associated with poor prognosis, and the identification of biomarkers of its severity could help in its treatment. In a pilot study, we observed high levels of acetone in the exhaled breath of patients with HF. The present study was designed to evaluate exhaled acetone as a biomarker of HF diagnosis and HF severity. Methods: Of 235 patients with systolic dysfunction evaluated between May 2009 and September 2010, 89 patients (HF group) fulfilled inclusion criteria and were compared with sex- and age-matched healthy subjects (control group, n = 20). Patients with HF were grouped according to clinical stability (acute decompensated HF [ADHF], n = 59; chronic HF, n = 30) and submitted to exhaled breath collection. Identification of chemical species was done by gas chromatography-mass spectrometry and quantification by spectrophotometry. Patients with diabetes were excluded. Results: The concentration of exhaled breath acetone (EBA) was higher in the HF group (median, 3.7 mu g/L; interquartile range [IQR], 1.69-10.45 mu g/L) than in the control group (median, 0.39 mu g/L; IQR, 0.30-0.79 mu g/L; P < .001) and higher in the ADHF group (median, 7.8 mu g/L; IQR, 3.6-15.2 mu g/L) than in the chronic HF group (median, 1.22 mu g/L; IQR, 0.68-2.19 P < .001). The accuracy and sensitivity of this method in the diagnosis of HF and ADHF were about 85%, a value similar to that obtained with B-type natriuretic peptide (BNP). EBA levels differed significantly as a function of severity of HF (New York Heart Association classification, P < .001). There was a positive correlation between EBA and BNP (r = 0.772, P < .001). Conclusions: EBA not only is a promising noninvasive diagnostic method of HF with an accuracy equivalent to BNP but also a new biomarker of HF severity. CHEST 2012; 142(2):457-466
Resumo:
This paper presents further results from our spectroscopic study of the globular cluster (GC) system of the group elliptical NGC 3923. From observations made with the GMOS instrument on the Gemini South Telescope, an additional 50 GC and ultra-compact dwarf (UCD) candidates have been spectroscopically confirmed as members of the NGC 3923 system. When the recessional velocities of these GCs are combined with the 29 GC velocities reported previously, a total sample of 79 GC/UCD velocities is produced. This sample extends to over 6 arcmin (>6 R-e similar to 30 kpc) from the centre of NGC 3923 and is used to study the dynamics of the GC system and the dark matter content of NGC 3923. It is found that the GC system of NGC 3923 displays no appreciable rotation, and that the projected velocity dispersion is constant with radius within the uncertainties. The velocity dispersion profiles of the integrated light and GC system of NGC 3923 are indistinguishable over the region in which they overlap. We find some evidence that the diffuse light and GCs of NGC 3923 have radially biased orbits within similar to 130 arcsec. The application of axisymmetric orbit-based models to the GC and integrated light velocity dispersion profiles demonstrates that a significant increase in the mass-to-light ratio (from M/L-V = 8 to 26) at large galactocentric radii is required to explain this observation. We therefore confirm the presence of a dark matter halo in NGC 3923. We find that dark matter comprises 17.5(-4.5)(+7.3) per cent of the mass within 1 R-e, 41.2(-10.6)(+18.2) per cent within 2 R-e and 75.6(-16.8)(+15.4) per cent within the radius of our last kinematic tracer at 6.9 R-e. The total dynamical mass within this radius is found to be 1.5(-0.25)(+0.4) x 10(12) M-circle dot. In common with other studies of large ellipticals, we find that our derived dynamical mass profile is consistently higher than that derived by X-ray observations, by a factor of around 2.