13 resultados para Flow distribution

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandstrom M, Park M, Costa EL, Hedenstierna G, Amato M. Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol 112: 225-236, 2012. First published September 29, 2011; doi: 10.1152/japplphysiol.01090.2010.-The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Variable rate sprinklers (VRS) have been developed to promote localized water application of irrigated areas. In Precision Irrigation, VRS permits better control of flow adjustment and, at the same time, provides satisfactory radial distribution profiles for various pressures and flow rates are really necessary. The objective of this work was to evaluate the performance and radial distribution profiles of a developed VRS which varies the nozzle cross sectional area by moving a pin in or out using a stepper motor. Field tests were performed under different conditions of service pressure, rotation angles imposed on the pin and flow rate which resulted in maximal water throw radiuses ranging from 7.30 to 10.38 m. In the experiments in which the service pressure remained constant, the maximal throw radius varied from 7.96 to 8.91 m. Averages were used of repetitions performed under conditions without wind or with winds less than 1.3 m s-1. The VRS with the four stream deflector resulted in greater water application throw radius compared to the six stream deflector. However, the six stream deflector had greater precipitation intensities, as well as better distribution. Thus, selection of the deflector to be utilized should be based on project requirements, respecting the difference in the obtained results. With a small opening of the nozzle, the VRS produced small water droplets that visually presented applicability for foliar chemigation. Regarding the comparison between the estimated and observed flow rates, the stepper motor produced excellent results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Foraminiferal data were obtained from 66 samples of box cores on the southeastern Brazilian upper margin (between 23.8A degrees-25.9A degrees S and 42.8A degrees-46.13A degrees W) to evaluate the benthic foraminiferal fauna distribution and its relation to some selected abiotic parameters. We focused on areas with different primary production regimes on the southern Brazilian margin, which is generally considered as an oligotrophic region. The total density (D), richness (R), mean diversity (H) over bar`, average living depth (ALD(X) ) and percentages of specimens of different microhabitats (epifauna, shallow infauna, intermediate infauna and deep infauna) were analyzed. The dominant species identified were Uvigerina spp., Globocassidulina subglobosa, Bulimina marginata, Adercotryma wrighti, Islandiella norcrossi, Rhizammina spp. and Brizalina sp.. We also established a set of mathematical functions for analyzing the vertical foraminiferal distribution patterns, providing a quantitative tool that allows correlating the microfaunal density distributions with abiotic factors. In general, the cores that fit with pure exponential decaying functions were related to the oligotrophic conditions prevalent on the Brazilian margin and to the flow of the Brazilian Current (BC). Different foraminiferal responses were identified in cores located in higher productivity zones, such as the northern and the southern region of the study area, where high percentages of infauna were encountered in these cores, and the functions used to fit these profiles differ appreciably from a pure exponential function, as a response of the significant living fauna in deeper layers of the sediment. One of the main factors supporting the different foraminiferal assemblage responses may be related to the differences in primary productivity of the water column and, consequently, in the estimated carbon flux to the sea floor. Nevertheless, also bottom water velocities, substrate type and water depth need to be considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of a thermal buttocks manikin(1) was explored as a tool to standardize the evaluation of seat comfort. Thermal manikin buttocks were developed and calibrated thermally and anatomically to simulate the sensible heat transfer of a seated person and used to evaluate interface pressure distribution. In essence, the pressure maps of manikin buttocks with and without heating were compared to those of a seated person. The results of average pressure demonstrated that the thermal manikins have a better response in interface pressure measurement than manikins without heating.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The theoretical E-curve for the laminar flow of non-Newtonian fluids in circular tubes may not be accurate for real tubular systems with diffusion, mechanical vibration, wall roughness, pipe fittings, curves, coils, or corrugated walls. Deviations from the idealized laminar flow reactor (LFR) cannot be well represented using the axial dispersion or the tanks-in-series models of residence time distribution (RTD). In this work, four RTD models derived from non-ideal velocity profiles in segregated tube flow are proposed. They were used to represent the RTD of three tubular systems working with Newtonian and pseudoplastic fluids. Other RTD models were considered for comparison. The proposed models provided good adjustments, and it was possible to determine the active volumes. It is expected that these models can be useful for the analysis of LFR or for the evaluation of continuous thermal processing of viscous foods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The classic conservative approach for thermal process design can lead to over-processing, especially for laminar flow, when a significant distribution of temperature and of residence time occurs. In order to optimize quality retention, a more comprehensive model is required. A model comprising differential equations for mass and heat transfer is proposed for the simulation of the continuous thermal processing of a non-Newtonian food in a tubular system. The model takes into account the contribution from heating and cooling sections, the heat exchange with the ambient air and effective diffusion associated with non-ideal laminar flow. The study case of soursop juice processing was used to test the model. Various simulations were performed to evaluate the effect of the model assumptions. An expressive difference in the predicted lethality was observed between the classic approach and the proposed model. The main advantage of the model is its flexibility to represent different aspects with a small computational time, making it suitable for process evaluation and design. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent (R) was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancy-driven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-epsilon turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous enzymatic interesterification is an alternative to chemical interesterification for lipid modification technology which is economically viable for large scale use. A blend of 70% lard and 30% soybean oil was submitted to continuous enzymatic interesterification in a glass tubular bioreactor at flow rate ranging from 0.5 to 4.5 mL/min. The original mixture and the reaction products obtained were examined to determine melting and crystallization behavior by DSC, and analyzed for regiospecific fatty acid distribution. Continuous enzymatic interesterification changed the mixture, forming a new triacylglycerol composition, verified by DSC curves and variation in enthalpy of melting values. The regiospecific distribution of fatty acids was changed by flow variations in the reactor. In the continuous enzymatic interesterification reaction the flow rate of 4.5 mL/min, was more advantageous than slower flow rates, reducing acyl migration and increasing process productivity. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present paper presents a theoretical analysis of a cross flow heat exchanger with a new flow arrangement comprehending several tube rows. The thermal performance of the proposed flow arrangement is compared with the thermal performance of a typical counter cross flow arrangement that is used in chemical, refrigeration, automotive and air conditioning industries. The thermal performance comparison has been performed in terms of the following parameters: heat exchanger effectiveness and efficiency, dimensionless entropy generation, entransy dissipation number, and dimensionless local temperature differences. It is also shown that the uniformity of the temperature difference field leads to a higher thermal performance of the heat exchanger. In the present case this is accomplished thorough a different organization of the in-tube fluid circuits in the heat exchanger. The relation between the recently introduced "entransy dissipation number" and the conventional thermal effectiveness has been obtained in terms of the "number of transfer units". A case study has been solved to quantitatively to obtain the temperature difference distribution over two rows units involving the proposed arrangement and the counter cross flow one. It has been shown that the proposed arrangement presents better thermal performance regardless the comparison parameter. (C) 2012 Elsevier Masson SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An experimental study on drag-reduction phenomenon in dispersed oil-water flow has been performed in a 26-mm-i.d. Twelve meter long horizontal glass pipe. The flow was characterized using a novel wire-mesh sensor based on capacitance measurements and high-speed video recording. New two-phase pressure gradient, volume fraction, and phase distribution data have been used in the analysis. Drag reduction and slip ratio were detected at oil volume fractions between 10 and 45% and high mixture Reynolds numbers, and with water as the dominant phase. Phase-fraction distribution diagrams and cross-sectional imaging of the flow suggested the presence of a higher amount of water near to the pipe wall. Based on that, a phenomenology for explaining drag reduction in dispersed flow in a flow situation where slip ratio is significant is proposed. A simple phenomenological model is developed and the agreement between model predictions and data, including data from the literature, is encouraging. (c) 2011 American Institute of Chemical Engineers AIChE J, 2012

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background In patients with advanced non-ischemic cardiomyopathy (NIC), right-sided cardiac disturbances has prognostic implications. Right coronary artery (RCA) flow pattern and flow reserve (CFR) are not well known in this setting. The purpose of this study was to assess, in human advanced NIC, the RCA phasic flow pattern and CFR, also under right-sided cardiac disturbances, and compare with left coronary circulation. As well as to investigate any correlation between the cardiac structural, mechanical and hemodynamic parameters with RCA phasic flow pattern or CFR. Methods Twenty four patients with dilated severe NIC were evaluated non-invasively, even by echocardiography, and also by cardiac catheterization, inclusive with Swan-Ganz catheter. Intracoronary Doppler (Flowire) data was obtained in RCA and left anterior descendent coronary artery (LAD) before and after adenosine. Resting RCA phasic pattern (diastolic/systolic) was compared between subgroups with and without pulmonary hypertension, and with and without right ventricular (RV) dysfunction; and also with LAD. RCA-CFR was compared with LAD, as well as in those subgroups. Pearson's correlation analysis was accomplished among echocardiographic (including LV fractional shortening, mass index, end systolic wall stress) more hemodynamic parameters with RCA phasic flow pattern or RCA-CFR. Results LV fractional shortening and end diastolic diameter were 15.3 ± 3.5 % and 69.4 ± 12.2 mm. Resting RCA phasic pattern had no difference comparing subgroups with vs. without pulmonary hypertension (1.45 vs. 1.29, p = NS) either with vs. without RV dysfunction (1.47 vs. 1.23, p = NS); RCA vs. LAD was 1.35 vs. 2.85 (p < 0.001). It had no significant correlation among any cardiac mechanical or hemodynamic parameter with RCA-CFR or RCA flow pattern. RCA-CFR had no difference compared with LAD (3.38 vs. 3.34, p = NS), as well as in pulmonary hypertension (3.09 vs. 3.10, p = NS) either in RV dysfunction (3.06 vs. 3.22, p = NS) subgroups. Conclusion In patients with chronic advanced NIC, RCA phasic flow pattern has a mild diastolic predominance, less marked than in LAD, with no effects from pulmonary artery hypertension or RV dysfunction. There is no significant correlation between any cardiac mechanical-structural or hemodynamic parameter with RCA-CFR or RCA phasic flow pattern. RCA flow reserve is still similar to LAD, independently of those right-sided cardiac disturbances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Introduction In this study we aimed to evaluate the peak cough flow (PCF) in healthy Brazilian subjects. Methods We evaluated 484 healthy subjects between 18 and 40 years old. Subjects were seated and oriented were asked to perform a maximal inspiration followed by a quick, short and explosive expiration on the peak flow meter. Three measures were carried out and recorded the average of the three results for each individual. Results The PCF values ranged between 240 and 500 L/min. The PCF values were lower in females than in males. The PCF was inversely proportional to age. Conclusion The values for Brazilian adult healthy subjects regarding PCF were between 240 and 500 L/min.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent® was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancydriven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-ε turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.