6 resultados para FREQUENCIES

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Exercise training (ET) can reduce blood pressure (BP) and prevent functional disability. However, the effects of low volumes of training have been poorly studied, especially in elderly hypertensive patients. Objectives: To investigate the effects of a multi-component ET program (aerobic training, strength, flexibility, and balance) on BP, physical fitness, and functional ability of elderly hypertensive patients. Methods: Thirty-six elderly hypertensive patients with optimal clinical treatment underwent a multi-component ET program: two 60-minute sessions a week for 12 weeks at a Basic Health Unit. Results: Compared to pre-training values, systolic and diastolic BP were reduced by 3.6% and 1.2%, respectively (p < 0.001), body mass index was reduced by 1.1% (p < 0.001), and peripheral blood glucose was reduced by 2.5% (p= 0.002). There were improvements in all physical fitness domains: muscle strength (chair-stand test and elbow flexor test; p < 0.001), static balance test (unipedal stance test; p < 0.029), aerobic capacity (stationary gait test; p < 0.001), except for flexibility (sit and reach test). Moreover, there was a reduction in the time required to perform two functional ability tests: "put on sock" and "sit down, stand up, and move around the house" (p < 0.001). Conclusions: Lower volumes of ET improved BP, metabolic parameters, and physical fitness and reflected in the functional ability of elderly hypertensive patients. Trial Registration RBR-2xgjh3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a slow-wave MEMS phase shifter that can be fabricated using the CMOS back-end and an additional maskless post-process etch. The tunable phase shifter concept is formed by a conventional slow-wave transmission line. The metallic ribbons that form the patterned floating shield of this type of structure are released to allow motion when a control voltage is applied, which changes the characteristic impedance and the phase velocity. For this device a quality factor greater than 40 can be maintained, resulting in a figure of merit on the order of 0.7 dB/360 degrees and a total area smaller than 0.14 mm(2) for a 60-GHz working frequency. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There is clinical evidence that very low and safe levels of amplitude-modulated electromagnetic fields administered via an intrabuccal spoon-shaped probe may elicit therapeutic responses in patients with cancer. However, there is no known mechanism explaining the anti-proliferative effect of very low intensity electromagnetic fields. METHODS: To understand the mechanism of this novel approach, hepatocellular carcinoma (HCC) cells were exposed to 27.12 MHz radiofrequency electromagnetic fields using in vitro exposure systems designed to replicate in vivo conditions. Cancer cells were exposed to tumour-specific modulation frequencies, previously identified by biofeedback methods in patients with a diagnosis of cancer. Control modulation frequencies consisted of randomly chosen modulation frequencies within the same 100 Hz-21 kHz range as cancer-specific frequencies. RESULTS: The growth of HCC and breast cancer cells was significantly decreased by HCC-specific and breast cancer-specific modulation frequencies, respectively. However, the same frequencies did not affect proliferation of nonmalignant hepatocytes or breast epithelial cells. Inhibition of HCC cell proliferation was associated with downregulation of XCL2 and PLP2. Furthermore, HCC-specific modulation frequencies disrupted the mitotic spindle. CONCLUSION: These findings uncover a novel mechanism controlling the growth of cancer cells at specific modulation frequencies without affecting normal tissues, which may have broad implications in oncology. British Journal of Cancer (2012) 106, 307-313. doi:10.1038/bjc.2011.523 www.bjcancer.com Published online 1 December 2011 (C) 2012 Cancer Research UK

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Brazilian population represents an admixture of native Amerindians, Portuguese settlers and Africans who were brought as slaves during the colonization period that began in the 16th century and was followed by waves of immigrations of Europeans and Asians in the 20th century. The contribution of these different ethnic groups to the constitution of Brazilian populations from different geographic regions is variable and, in addition to environmental factors, might act by determining different allele profiles among Brazilian populations from different regions. We studied polymorphic sites at the 3' untranslated region of the HLA-G gene in individuals from a Northeastern Brazilian region and compared them to our previously published data about a Southeastern Brazilian region, located at a distance of 2589 km. Our results showed that most polymorphic sites present a similar distribution in both populations, except for the lower frequency of the +3003C allele in the Northeastern population compared to the Southeastern population. Although differences in genotypic distribution were only significant for the +3003 locus (P = 0.0201), the diversity of haplotypes was distinct for each population. These results are important for casecontrol studies on the association of human leucocyte antigen-G polymorphism with disease and also in terms of the genetic structure of two distinct Brazilian populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Torque teno sus virus (TTSuV) is emergent in swine herds. Recent studies have shown an increased frequency of TTSuV2 in Porcine circovirus type 2 (PCV2)-associated diseases (PCVAD), which are endemic in many swine-producing countries, including Brazil. Coinfection with several other viral and bacterial agents results in an increased incidence of more severe PCVAD. Given the limited information on TTSuV and PCV2 coinfection, especially in Brazilian swine herds, this study made a preliminary estimation of the occurrence of coinfection in swine herds by testing samples from different categories. Between 2008 and 2009, 111 samples of feces and 23 serum samples from 5 swine herds were tested for PCV2 and TTSuVs and the results analyzed for associations between these agents. No significant differences in coinfection frequency were observed for PCV2 1 + TTSuV1 or for PCV2 1 TTSuV2 between nursery piglets (P = 0.730), growing pigs (P = 0.331), or sows (P = 0.472). However, a significant difference was observed for PCV2 1 TTSuV1 1 TTSuV2 between nursery piglets and growing pigs (P = 0.004; Fisher's exact test). Phylogenetic studies agreed with the grouping of TTSuV1 and TTSuV2 into 2 different clades, with no distinct pattern of clustering of these isolates with the animal categories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the effects on micromorphology and temperature rise in human dentin using different frequencies of Er:YAG laser. Sixty human dentin fragments were randomly assigned into two groups (n = 30): carious or sound dentin. Both groups were divided into three subgroups (n = 10), according to the Er:YAG laser frequency used: 4, 6, or 10 Hz (energy: 200 mJ; irradiation distance: 12 mm; and irradiation time: 20 s). A thermocouple adapted to the tooth fragment recorded the initial temperature value (degrees C); then, the temperature was measured after the end of the irradiation (20 s). Morphological analysis was performed using images obtained with scanning electron microscope. There was no difference between the temperatures obtained with 4 and 6 Hz; the highest temperatures were achieved with 10 Hz. No difference was observed between carious and sound dentin. Morphological analyses revealed that all frequencies promoted irregular surface in sound dentin, being observed more selectively ablation especially in intertubular dentin with tubule protrusion. The caries dentin presented flat surface for all frequencies used. Both substrates revealed absence of any signs of thermal damage. It may be concluded that the parameters used in this study are capable to remove caries lesion, having acceptable limits of temperature rise and no significant morphological alterations on dentin surface. Microsc. Res. Tech. 2012. (c) 2012 Wiley Periodicals, Inc.