11 resultados para Electromyographic
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
This study, using surface electromyography, analyzed the activity of the masseter muscles of 30 patients with facial bone fractures that were surgically treated. Evaluations were made before surgery and in the 7th, 30th, and 60th days after surgery. The value of each measure and the average of 3 maximum voluntary isometric contractions lasting 5 seconds each were registered, and statistical analyses were performed. Patients had a mean age of 31 years and an average of 1.33 fractures. They were grouped according to the type of fracture as follows: mandibular (50%), zygomatic complex (33%), maxilla (10%), and associated fractures (6.7%). There was a lower masseter activity in the preoperative period, when compared with normal values in all groups of fractures. There was a sharp drop in the masseter activity in the postoperative period of 7 days, and all groups showed recovery of activity in 60 days but still below the normal value referenced in the literature. The mean values of the masseter activity, in descending order, were from the zygomatic complex, mandibular, maxillary, and associated fractures. The unilateral mandibular fractures showed higher values than the bilateral fractures in most of the evaluations. There was a highly significant difference in the comparison of the evolution of the masseter activity on both sides, for mandibular and zygomatic complex fractures, and the pairwise comparison showed significant difference between most groups. It was concluded that facial fractures and surgical procedures had negative effects in the muscle activity as observed using electromyography.
Resumo:
This study examined whether there is an association between surface electromyography (EMG) of masticatory muscles, orofacial myofunction status and temporomandibular disorder (TMD) severity scores. Forty-two women with TMD (mean 30 years, SD 8) and 18 healthy women (mean 26 years, SD 6) were examined. According to the Research Diagnostic Criteria for TMD (RDC/TMD), all patients had myogenous disorders plus disk displacements with reduction. Surface EMG of masseter and temporal muscles was performed during maximum teeth clenching either on cotton rolls or in intercuspal position. Standardized EMG indices were obtained. Validated protocols were used to determine the perception severity of TMD and to assess orofacial myofunctional status. TMD patients showed more asymmetry between right and left muscle pairs, and more unbalanced contractile activities of contralateral masseter and temporal muscles (p < 0.05, t-test), worse orofacial myofunction status and higher TMD severity scores (p < 0.05, Mann-Whitney test) than healthy subjects. Spearman coefficient revealed significant correlations between EMG indices, orofacial myofunctional status and TMD severity (p < 0.05). In conclusion, these methods will provide useful information for TMD diagnosis and future therapeutic planning. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Objective: This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods: The operators prepared one canal with RaCe rotary instruments and another with Flexofiles. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radial's, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results: There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion: The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.
Resumo:
Twelve participants ran (9 km . h(-1)) to test two types of running shoes: replica and original shoes. Ground reaction force, plantar pressure and electromyographic activity were recorded. The shoes were tested randomly and on different days. Comparisons between the two experimental conditions were made by analysis of variance (ANOVA) test (P <= 0.05). The time to first peak, loading rate of the first peak and impulse of the first 75 ms of stance were significantly different between the shoes (P <= 0.05), revealing an increase of impact forces for the replica shoes. The peak plantar pressure values were significantly higher (P <= 0.05) when wearing replica shoes. During running, the contact area was significantly smaller (P <= 0.05) for the replica shoe. The electromyographic activity of the analysed muscles did not show changes between the two shoes in running. These findings suggest that the use of replica running shoes can increase the external load applied to the human body, but may not change the muscle activity pattern during locomotion. This new mechanical situation may increase the risk of injuries in these movements.
Resumo:
The Lucia jig is a technique that promotes neuromuscular reprogramming of the masticatory system and allows the stabilization of the mandible without the interference of dental contacts, maintaining the mandible position in harmonic condition with the musculature in normal subjects or in patients with temporomandibular dysfunction (TMD). This study aimed to electromyographically analyze the activity (RMS) of the masseter and temporal muscles in normal subjects (control group) during the use of an anterior programming device, the Lucia jig, in place for 0, 5, 10, 20 and 30 minutes to demonstrate its effect on the stomatognathic system. Forty-two healthy dentate individuals (aged 21 to 40 years) with normal occlusion and without parafunctional habits or ternporomandibular dysfunction (RDC/TMD) were evaluated on the basis of the electromyographic activity of the masseter and temporal muscles before placement of a neuromuscular re-programming device, the Lucia jig, on the upper central incisors. There were no statistically significant differences (p < 0.05) in the electromyographic activity of the masticatory muscles in the different time periods. The Lucia jig changed the electromyographic activity by promoting a neuromuscular reprogramming. In most of the time periods, it decreased the activation of the masticatory muscles, showing that this device has wide applicability in dentistry. The use of a Lucia jig over 0, 5, 10, 15, 20 and 30 minutes did not promote any statistically significant increase in muscle activity despite differences in the data, thus showing that this intra-oral device can be used in dentistry.
Resumo:
The purpose of this study was to assess the effect of low level laser therapy on subjects with intra-articular temporomandibular disorders (IA-TMD), and to quantify and compare severity of signs and symptoms before, during, and after the laser applications. The sample consisted of 45 subjects randomly divided into three groups (G) of 15 subjects each: G-I: 15 individuals with IA-TMD submitted to an energy dose of 52.5 J/cm(2); G-II: dose of 105.0 J/cm(2); and G-III: placebo group (0 J/cm(2)). In all groups, the applications were performed on condylar points on the masseter and anterior temporalis muscles. Two weekly sessions were held for five weeks, totaling 10 applications. The assessed variables were: mandibular movements and painful symptoms evoked by muscle palpation. These variables were measured before starting the study, then immediately after the first, fifth, and tenth laser application, and finally, 32 days after completing the applications. The results showed that there were statistically significant differences for G-I and G-II at the level of 1% between the doses, as well as between assessments. Therefore, it was concluded that the use of low level laser increased the mean mandibular range of motion and reduced painful symptoms in the groups that received effective treatment, which did not occur in the placebo group.
Resumo:
Objective parameters that could provide a basis for food texture selection for elderly or dysphagic patients have not been established. We, therefore, aimed to develop a precise method of measuring large particles (>2 mm in diameter) in a bolus and an analytical method to provide a scientific rationale for food selection under masticatory dysfunction conditions. We developed a new illumination system to evaluate the ability of twenty female participants (mean age, 23.4 +/- 4.3 years) to masticate carrots, peanuts and beef with full, half and one quarter of the number of masticatory strokes. We also evaluated mastication under suppressed force, regulated by 20% electromyographic of the masseter muscle. The intercept and inclination of the regression line for the distribution of large particles were adopted as coefficients for the discrimination of masticatory efficiency. Single set of coefficient thresholds of 0.10 for the intercept and 1.62 for the inclination showed excellent discrimination of masticatory conditions for all three test foods with high specificity and sensitivity. These results suggested that our method of analysing the distribution of particles >2 mm in diameter might provide the basis for the appropriate selection of food texture for masticatory dysfunction patients from the standpoint of comminution.
Resumo:
Purpose: due to the presence of major masticatory dysfunction in patients with temporomandibular joint (TMJ) ankylosis, this study analyzed mouth opening and EMG activity of masticatory muscles in order to detect changes in these parameters after surgical release of mandible ankylosis. Method: in 7 patients with temporomandibular ankylosis, between 7 and 30 years (median = 9 years), the distance was measured as interincisal maximum active (DIMA) and we recorded the electromyographic activity (EMG) of masseter and temporal muscles during voluntary isometric contraction (VIC) and chewing, comparing the data before and after surgery using the Wilcoxon test. Results: higher values were observed for DIMA after surgery (p=0.0277), the asymmetry index showed no difference between the two evaluated periods for both studied muscles, the values of the EMG during VIC decreased after surgery for the right (p=0.0179) and left (p=0.0179) masseter but not for the temporal muscle, there were no changes in EMG values for the studied muscles during mastication. Conclusion: the surgical release of TMJ ankylosis resulted in an increase of mouth opening and decreased amplitude of action potentials generated during maximum isometric voluntary contraction of the masseter muscle on both sides, this did not change the asymmetry index of the masseter and temporal as well as the electromyographic activity of the temporal muscle bilaterally during isometric contraction and masseter and temporal muscles during mastication.
Resumo:
O agachamento afundo possui um posicionamento dos membros inferiores diferencial em relação ao agachamento padrão, necessitando de maiores esclarecimentos acerca das participações dos músculos envolvidos. O objetivo foi analisar a atividade eletromiográfica dos músculos vastus lateralis (VL), vastus medialis (VM), bíceps femoris (BF) e semitendinosus (ST) durante a execução do agachamento afundo até à exaustão com o membro inferior posicionado frontalmente e posteriormente. Participaram do estudo nove mulheres ativas com média (DP) de idade de 22 (3,4) anos e massa corporal 60,3 (4,1) kg. O agachamento afundo foi dividido em duas etapas, diferindo apenas o posicionamento do membro inferior dominante (randomizado). Os sinais eletromiográficos foram captados utilizando um eletromiógrafo e analisados os valores "root mean square" (RMS) na fase concêntrica. Os resultados indicaram um aumento significativo do RMS em função do tempo para o membro inferior posicionado frontalmente e posteriormente (p< 0,001). No membro posicionado frontalmente, o aumento do RMS correspondeu a 50% para o VL, 54% para o VM e 48% para o BF. O membro posicionado posteriormente apresentou um aumento de 75% para o VL, 113% para o VM, 62% para o BF e 48% para o ST. O RMS também foi significativamente maior no músculo VM em relação ao ST no membro inferior posicionado anteriormente (p = 0,03) e em relação ao ST e BF no membro inferior posicionado posteriormente (p = 0,02). Não ocorreu interação significativa entre o efeito do tempo e músculo na atividade eletromiográfica. O RMS normalizado não apresentou diferenças estatisticamente significativas no que se refere ao posicionamento do membro inferior dominante. A atividade muscular foi semelhante em ambos os posicionamentos do membro inferior, apresentando maior aumento de ativação dos músculos VL e VM em relação ao BF e ST.
Resumo:
OBJETIVO: Caracterizar o controle motor dos músculos masseter e temporal e a morfologia do músculo masseter em atividades da função mastigatória em indivíduos com oclusão normal; verificar a compatibilidade entre os exames de eletromiografia de superfície (EMGs) e ultrassonografia (USG). MÉTODOS: Participaram 22 indivíduos adultos, de ambos os gêneros, sem alterações no sistema miofuncional orofacial. Os procedimentos adotados para avaliação dos participantes foram: EMGs dos músculos masseteres (MM) e temporais (MT); e USG dos MM, na realização de três tarefas - repouso muscular, apertamento dentário com algodão, apertamento dentário sem algodão. RESULTADOS: Para análise estatística dos dados foram utilizados os testes de Kolmogorv-Smirnov, teste-T pareado e Correlação de Spearman, com nível de significância de 5%. Na EMGs observou-se diferença entre a ativação de MM e MT no apertamento dentário com e sem algodão, sendo MT mais ativo que MM em ambas as tarefas. Não foram observadas diferenças entre as hemifaces, tanto na EMGs quanto na USG. Observou-se também correlação positiva entre os exames na condição de apertamento dentário sem algodão esquerdo e na condição de apertamento dentário esquerdo com algodão, e tendência à significância no apertamento dentário direito sem algodão. CONCLUSÃO: A associação da EMGs e USG na investigação da funcionalidade muscular traz importantes informações sobre fisiologia da musculatura esquelética. Os resultados do presente estudo indicam haver correlação entre a EMGs e a USG, ou seja, o aumento da atividade elétrica e o aumento correspondente da espessura do músculo.
Resumo:
Abstract Background: Coactivation may be both desirable (injury prevention) or undesirable (strength measurement). In this context, different styles of muscle strength stimulus have being investigated. In this study we evaluated the effects of verbal and visual stimulation on rectus femoris and biceps femoris muscles contraction during isometric and concentric. Methods: We investigated 13 men (age =23.1 ± 3.8 years old; body mass =75.6 ± 9.1 kg; height =1.8 ± 0.07 m). We used the isokinetic dynamometer BIODEX device and an electromyographic (EMG) system. We evaluated the maximum isometric and isokinetic knee extension and flexion at 60°/s. The following conditions were evaluated: without visual nor verbal command (control); verbal command; visual command and; verbal and visual command. In relation to the concentric contraction, the volunteers performed five reciprocal and continuous contractions at 60°/s. With respect to isometric contractions it was made three contractions of five seconds for flexion and extension in a period of one minute. Results: We found that the peak torque during isometric flexion was higher in the subjects in the VVC condition (p > 0.05). In relation to muscle coactivation, the subjects presented higher values at the control condition (p > 0.05). Conclusion We suggest that this type of stimulus is effective for the lower limbs.