6 resultados para Electrocardiogram

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although low- and middle-income countries still bear the burden of major infectious diseases, chronic noncommunicable diseases are becoming increasingly common due to rapid demographic, epidemiologic, and nutritional transitions. However, information is generally scant in these countries regarding chronic disease incidence, social determinants, and risk factors. The Brazilian Longitudinal Study of Adult Health (ELSA-Brasil) aims to contribute relevant information with respect to the development and progression of clinical and subclinical chronic diseases, particularly cardiovascular diseases and diabetes. In this report, the authors delineate the study's objectives, principal methodological features, and timeline. At baseline, ELSA-Brasil enrolled 15,105 civil servants from 5 universities and 1 research institute. The baseline examination (2008-2010) included detailed interviews, clinical and anthropometric examinations, an oral glucose tolerance test, overnight urine collection, a 12-lead resting electrocardiogram, measurement of carotid intima-media thickness, echocardiography, measurement of pulse wave velocity, hepatic ultrasonography, retinal fundus photography, and an analysis of heart rate variability. Long-term biologic sample storage will allow investigation of biomarkers that may predict cardiovascular diseases and diabetes. Annual telephone surveillance, initiated in 2009, will continue for the duration of the study. A follow-up examination is scheduled for 2012-2013.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The study aimed to assess electrocardiographic alterations during oral implant placement surgeries under local anesthesia (lidocaine chlorhydrate with epinephrine), using 15 mg of midazolam as an anxiolytic premedication. Material and methods: The study randomly selected 20 patients, aged 21-50 years old, requiring bilateral mandibular dental implants. Each patient was assessed using placebo on one side and midazolam on the contralateral side, with random, double-blinded distribution. The electrocardiogram recorded 12 static leads every 2 min, while D2 derivations were recorded continuously. Results: No statistically significant differences were observed between the placebo and midazolam when analyzing the morphological behavior of the electrocardiographic wave and the presence of arrhythmias during the experiment. However, under sedation, assessment of the behavior of electrocardiographic parameters during different stages of the procedure revealed statistically significant differences (P<0.05) for heart rate, P-wave amplitude and duration of the RR and QTc intervals. The arrhythmias detected were considered low risk for patients without systemic alterations and were observed in 53.3% of patients. The most frequently occurring alterations were tachycardia, bradycardia, supraventricular and ventricular extrasystoles and blocked atrial extrasystole, which were similar for both placebo and midazolam, with the greatest incidence during the initial, incision and bone drilling stages. Conclusion: The use of 15 mg of midazolam made no difference compared with the placebo. The use of 15 mg of midazolam did not show an advantage in the incidence of arrhythmias The anxiolytic premedication does not prevent myocardial arrhythmias in endosseous implant placement. The clinical significance of the arrhythmias may not represent serious risks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents the electrocardiogram findings from 97 captive tufted capuchin monkeys (Cebus apella) at the Sao Paulo Zoo (Sao Paulo, Brazil) while under ketamine anesthesia. The results did not differ greatly from data of domestic carnivores or other studied primate species. The most common rhythm recorded was normal sinus rhythm, followed by normal sinus rhythm with wandering pacemaker. Electrical axis varied from 0 degrees to -150 degrees but was most commonly between +60 degrees and +90 degrees. QRS complexes were predominantly positive in leads DI, DII, DIII, and AVF. These findings allow for the recognition of abnormal rhythms in these primate species and can contribute to future investigations into the cardiovascular diseases routinely diagnosed in primates and humans.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Atrial fibrillation (AF) is a controversial risk factor for dementia. Objective: The objective of this study was to assess the association between AF and dementia in the "Sao Paulo Ageing & Health" (SPAH) study participants. Methods: SPAH is a cross-sectional, population-based study of elderly people living in a deprived neighborhood in Sao Paulo, Brazil. Dementia diagnosis was performed according to the 10/66 study group protocol based on Diagnostic and Statistical Manual of Mental Disorders (DSM-IV) criteria. Diagnosis of AF was made using a 12-lead electrocardiogram (ECG) recording, which was assessed by two cardiologists. Data on demographics and cardiovascular risk factors were also obtained. Results: Dementia was diagnosed in 66 (4.3%) and AF in 36 (2.4%) of 1,524 participants with a valid ECG. The crude odds ratio (OR) for dementia in participants with AF was 2.8 (95% confidence interval [CI]: 1.0-8.1; p=0.06) compared with individuals without AF. When analyzing data according to sex, a positive relationship was found in women (OR 4.2; 95% CI: 1.24-15.1; p=0.03). After age-adjustment, however, this association was no longer significant (OR 2.2; 95% CI: 0.6-8.9; p=0.26). Conclusion: There was no independent association between AF and dementia in this sample. The prevalence of AF may be low in this population owing to premature cardiovascular death. (Arq Bras Cardiol 2012;99(6):1108-1114)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Clinical multistage risk assessment associated with electrocardiogram (ECG) and NT-proBNP may be a feasible strategy to screen hypertrophic cardiomyopathy (HCM). We investigated the effectiveness of a screening based on ECG and NT-proBNP in first-degree relatives of patients with HCM. Methods and Results: A total of 106 first-degree relatives were included. All individuals were evaluated by echocardiography, ECG, NT-proBNP, and molecular screening (available for 65 individuals). From the 106 individuals, 36 (34%) had diagnosis confirmed by echocardiography. Using echocardiography as the gold standard, ECG criteria had a sensitivity of 0.71, 0.42, and 0.52 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Mean values of NT-ProBNP were higher in affected as compared with nonaffected relatives (26.1 vs. 1290.5, P < .001). The AUC of NT-proBNP was 0.98. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.92 and specificity of 0.96. Using molecular genetics as the gold standard, ECG criteria had a sensitivity of 0.67, 0.37, and 0.42 for the Romhilt-Estes, Sokolow-Lyon, and Cornell criteria, respectively. Using a cutoff value of 70 pg/mL, we observed a sensitivity of 0.83 and specificity of 0.98. Conclusion: Values of NT-proBNP above 70 pg/mL can be used to effectively select high-risk first-degree relatives for HCM screening. (J Cardiac Fail 2012;18:564-568)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sickle cell anemia (SCA) is associated to increased cardiac output, normal heart rate (HR), abnormal QT dispersion and lower diastolic blood pressure (DBP). The mechanisms are still unknown. The objective of this study was to test the hypothesis that there is cardiovascular autonomic dysfunction (CAD) in SCA. The secondary objectives were to distinguish the roles of chronic anemia and hemoglobinopathy and to evaluate the predominance of the sympathetic or parasympathetic systems in the pathogenesis of CAD. Sixteen subjects with SCA, 13 with sickle cell trait (SCT), 13 with iron deficiency anemia (IDA), and 13 healthy volunteers (HV) were evaluated. All subjects were submitted to 24 h-electrocardiogram (24 h-ECG), plasma norepinephrine (NE) measurement before and after isometric exercise (IE), and also Valsalva maneuver (VM), diving maneuver (DV), and tilt test (TT). Baroreflex sensitivity (BRS) was also evaluated. The minimum, average and maximum HR as well as the percentage of bradycardia and tachycardia at 24-h ECG were similar in all groups. NE at baseline and after IE did not differ between groups. The SCA group showed less bradycardia at phase IV of VM, less bradycardia during DV, and also less tachycardia and lower DBP during TT. BRS for bradycardia and tachycardia reflex was decreased in the SCA and SCT groups. In conclusion, 1) there is CAD in SCA, and it is characterized by the reduction of BRS and the limitation of HR modulation mediated by the parasympathetic system; 2) cardiovascular sympathetic activity is preserved in SCA; and 3) hemoglobinopathy is the preponderant ethiopathogenic factor. (C) 2011 Elsevier B.V. All rights reserved.