9 resultados para Electrically conducting fluids

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ion implantation of metal species into insulators provides a tool for the formation of thin, electrically conducting, surface layers with experimenter-controlled resistivity. High energy implantation of Pt and Ti into alumina accelerator components has been successfully employed to control high voltage surface breakdown in a number of cases. In the work described here we have carried out some basic investigations related to the origin of this phenomenon. By comparison of the results of alumina implanted with Ti at 75 keV with the results of prior investigations of polymers implanted with Pt at 49 eV and Au at 67 eV, we describe a physical model of the effect based on percolation theory and estimate the percolation parameters for the Ti-alumina composite. We estimate that the percolation dose threshold is about 4 x 10(16) cm(-2) and the maximum dose for which the system remains an insulator-conductor composite is about 10 x 10(16) cm(-2). The saturation electrical conductivity is estimated to be about 50 S/m. We conclude that the observed electrical conductivity properties of Ti-implanted alumina can be satisfactorily described by percolation theory. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.3697900]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The corrosion protection of AA6063 aluminium alloy by cerium conversion, polyaniline conducting polymer and by duplex coatings has been investigated. The electrochemical behaviour was evaluated in aerated 3.5 wt.% NaCl. All coatings tested shifted the corrosion and pitting potentials to more positive values, indicating protection against corrosion. The duplex coatings are significantly more effective than each coating alone: corrosion and pitting potentials were shifted by +183 and +417 mV(SCE), respectively, by duplex coatings in relation to the untreated aluminium alloy. Optical microscopy and scanning electron microscopy are in agreement with the electrochemical results, reinforcing the superior performance of duplex coatings. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We show that a single imperfect fluid can be used as a source to obtain a mass-varying black hole in an expanding universe. This approach generalizes the well-known McVittie spacetime, by allowing the mass to vary thanks to a novel mechanism based on the presence of a temperature gradient. This fully dynamical solution, which does not require phantom fields or fine-tuning, is a step forward in a new direction in the study of systems whose local gravitational attraction is coupled to the expansion of the universe. We present a simple but instructive example for the mass function and briefly discuss the structure of the apparent horizons and the past singularity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports an experimental method to estimate the convective heat transfer of cutting fluids in a laminar flow regime applied on a thin steel plate. The heat source provided by the metal cutting was simulated by electrical heating of the plate. Three different cooling conditions were evaluated: a dry cooling system, a flooded cooling system and a minimum quantity of lubrication cooling system, as well as two different cutting fluids for the last two systems. The results showed considerable enhancement of convective heat transfer using the flooded system. For the dry and minimum quantity of lubrication systems, the heat conduction inside the body was much faster than the heat convection away from its surface. In addition, using the Biot number, the possible models were analyzed for conduction heat problems for each experimental condition tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We address the spherical accretion of generic fluids onto black holes. We show that, if the black hole metric satisfies certain conditions, in the presence of a test fluid it is possible to derive a fully relativistic prescription for the black hole mass variation. Although the resulting equation may seem obvious due to a form of it appearing as a step in the derivation of the Schwarzschild metric, this geometrical argument is necessary to fix the added degree of freedom one gets for allowing the mass to vary with time. This result has applications on cosmological accretion models and provides a derivation from first principles to serve as a basis to the accretion equations already in use in the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stability of oil-in-water (O/W) emulsions used as metalworking fluids is a key factor for the economical and environmental balance of the entire metalworking process because used and broken fluids must be recycled or disposed. In this study, the ability of turbidimetric spectroscopy in the ultraviolet and visible light range to detect metalworking fluids destabilization was evaluated. Destabilization was achieved by adding calcium chloride, thus achieving accelerated aging, which leads to coalescence, creaming, and complete emulsion separation. The stability of the metalworking fluids at 5% volumetric concentration in deionized water was monitored using a spectroscopic turbidimeter composed of an optical probe for in-line measurements. Destabilization was also monitored by measuring the vertical profile of backscattered and transmitted light. The results of this offline measurement system were compared with those from the in-line spectroscopic sensor, indicating that the latter can provide local, real-time information on emulsion destabilization, thus enabling control actions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal tissues are frequently discarded before (amniocentesis) or after birth, which both facilitates stem cell access and helps to overcome ethical concerns. In the present study, we aimed to isolate and characterize stem cells from the allantoic and amniotic fluids (ALF; AMF) of third trimester canine fetuses. This gestation age has not been previously explored for stem cells isolation. The gestational age, cell culture conditions and method of isolation used in this study allowed for the establishment and efficient expansion of ALF and AMF cells. We showed that the majority of ALF and ALF cells express the stem cell markers, such as vimentin, nestin and cytokeratin 18 (CK18). Under appropriate culture conditions AMF derived cells can undergo differentiation into osteogenic, adipogenic, chondrogenic and neuron-like lineages. ALF derived cells showed adipogenic, and chondrogenic potential. Therefore, ALF and AMF cells derived at the third gestation trimester can be qualified as progenitor stem cells, accordingly referred as (alantoic fluid progenitor/stem) ALF PS cells and (amniotic fluid progenitor/stem) AMF PS cells. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study investigates gel polymer electrolytes (GPEs) based on sodium alginate plasticized with glycerol containing either CH3COOH or LiClO4. The membranes showed ionic conductivity results of 3.1 x 10(-4) S/cm for the samples with LiClO4 and 8.7x10(-5) S/cm for the samples with CH3COOH at room temperature. The samples also showed thermal stability up to 160 degrees C, transparency of up to 90%, surface uniformity and adhesion to glass and steel. Moreover, Dynamic Mechanical Analysis revealed two relaxations for both samples and the Ea values were between 18 and 36 kJ/mol. All the results obtained indicate that alginate-based GPEs can be used as electrolytes in electrochemical devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ionic conducting membranes of gelatin plasticized with glycerol and containing LiI/I-2 have been obtained and characterized by X-ray diffraction measurements, UV-Vis-NIR spectroscopy, thermal analysis and impedance spectroscopy. The transparent (80-90% in the visible range) membranes showed ionic conductivity value of 5 x 10(-5) S/cm at room temperature, which increased to 3 x 10(-3) S/cm at 80 degrees C. All the ionic conductivity measurements as a function of temperature showed VTF dependence and activation energy of 8 kJ/mol. These samples also showed low glass transition temperature of -76 degrees C. Moreover the samples were predominantly amorphous. The membranes applied to small electrochromic devices showed 20% of color change from colored to bleached states during more than 70 cronoamperometric cycles.