2 resultados para EDI

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The study goal was to compare the efficacy of expressed breast milk (EBM) versus 25% glucose on pain responses of late preterm infants during heel lancing. METHODS: In a noninferiority randomized controlled trial, a total of 113 newborns were randomized to receive EBM (experimental group [EG]) or 25% glucose (control group [CG]) before undergoing heel lancing. The primary outcome was pain intensity (Premature Infant Pain Profile [PIPP]) and a 10% noninferiority margin was established. Secondary outcomes were incidence of cry and percentage of time spent crying and adverse events. Intention-to-treat (ITT) analysis was used. RESULTS: Groups were similar regarding demographics and clinical characteristics, except for birth weight and weight at data collection day. There were lower pain scores in the CG over 3 minutes after lancing (P<.001). A higher number of infants in the CG had PIPP scores indicative of minimal pain or absence of pain (P = .002 and P = .003 on ITT analysis) at 30 seconds after lancing, and the mean difference in PIPP scores was 3 (95% confidence interval: 1.507-4.483). Lower incidence of cry (P = .001) and shorter duration of crying (P = .014) were observed for CG. Adverse events were benign and self-limited, and there was no significant difference between groups (P = .736 and P = .637 on ITT analysis). CONCLUSIONS: Results based on PIPP scores and crying time indicate poorer effects of EBM compared with 25% glucose during heel lancing. Additional studies exploring the vol and administration of EBM and its combination with other strategies such as skin-to-skin contact and sucking are necessary. Pediatrics 2012;129:664-670

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rationale: NAVA is an assisted ventilatory mode that uses the electrical activity of the diaphragm (Edi) to trigger and cycle the ventilator, and to offer inspiratory assistance in proportion to patient effort. Since Edi varies from breath to breath, airway pressure and tidal volume also vary according to the patient's breathing pattern. Our objective was to compare the variability of NAVA with PSV in mechanically ventilated patients during the weaning phase. Methods: We analyzed the data collected for a clinical trial that compares PSV and NAVA during spontaneous breathing trials using PSV, with PS of 5 cmH2O, and NAVA, with Nava level titrated to generate a peak airway pressure equivalent to PSV of 5 cmH2O (NCT01137271). We captured flow, airway pressure and Edi at 100Hz from the ventilator using a dedicated software (Servo Tracker v2, Maquet, Sweden), and processed the cycles using a MatLab (Mathworks, USA) code. The code automatically detects the tidal volume (Vt), respiratory rate (RR), Edi and Airway pressure (Paw) on a breath-by-breath basis for each ventilatory mode. We also calculated the coefficient of variation (standard deviation, SD, divided by the mean). Results: We analyzed data from eleven patients. The mean Vt was similar on both modes (370 ±70 for Nava and 347± 77 for PSV), the RR was 26±6 for Nava and 26±7 or PSV. Paw was higher for Nava than for PSV (14±1 vs 11±0.4, p=0.0033), and Edi was similar for both modes (12±8 for Nava and 11±6 for PSV). The variability of the respiratory pattern, assessed with the coefficient of variation, was larger for Nava than for PSV for the Vt ( 23%±1% vs 15%±1%, p=0.03) and Paw (17%±1% vs 1% ±0.1%, p=0.0033), but not for RR (21% ±1% vs 16% ±8%, p=0.050) or Edi (33%±14% vs 39% ±16%,p=0.07). Conclusion: The variability of the breathing pattern is high during spontaneous breathing trials independent of the ventilatory mode. This variability results in variability of airway pressure and tidal volume, which are higher on Nava than on PSV. Our results suggest that Nava better reflects the normal variability of the breathing pattern during assisted mechanical ventilation.