13 resultados para Document imaging system

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The software Seed Vigor Imaging System (SVIS®), has been successfully used to evaluate seed physiological potential by automated analyses of scanned seedlings. In this research, the efficiency of this system was compared to other tests accepted for assessing cucumber (Cucumis sativus L.) seed vigor of distinct seed lots of Supremo and Safira cultivars. Seeds were subjected to germination, traditional and saturated salt accelerated aging, seedling emergence, seedling length and SVIS analyses (determination of vigor indices and seedling growth uniformity, lengths of primary root, hypocotyl and whole seedlings). It was also determined whether the definition of seedling growth/uniformity ratios affects the sensitivity of the SVIS®. Results showed that analyses SVIS have provided consistent identification of seed lots performance, and have produced information comparable to those from recommended seed vigor tests, thus demonstrating a suitable sensitivity for a rapid and objective evaluation of physiological potential of cucumber seeds. Analyses of four-days-old cucumber seedlings using the SVIS® are more accurate and growth/uniformity does not affect the precision of results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The development of new procedures for quickly obtaining accurate information on the physiological potential of seed lots is essential for developing quality control programs for the seed industry. In this study, the effectiveness of an automated system of seedling image analysis (Seed Vigor Imaging System - SVIS) in determining the physiological potential of sun hemp seeds and its relationship with electrical conductivity tests, were evaluated. SVIS evaluations were performed three and four days after sowing and data on the vigor index and the length and uniformity of seedling growth were collected. The electrical conductivity test was made on 50 seed replicates placed in containers with 75 mL of deionised water at 25 ºC and readings were taken after 1, 2, 4, 8 and 16 hours of imbibition. Electrical conductivity measurements at 4 or 8 hours and the use of the SVIS on 3-day old seedlings can effectively detect differences in vigor between different sun hemp seed lots.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, image analysis is one of the most modern tools in evaluating physiological potential of seeds. This study aimed at verifying the efficiency of the seedling imaging analysis to assess physiological potential of wheat seeds. The seeds of wheat, cultivars IAC 370 and IAC 380, each of which represented by five different lots, were stored during four months under natural environmental conditions of temperature (T) and relative humidity (RH), in municipality of Piracicaba, Stated of São Paulo, Brazil. For this, bimonthly assessments were performed to quantify moisture content and physiological potential of seeds by means of tests of: germination, first count, accelerated aging, electrical conductivity, seedling emergence, and computerized analysis of seedlings, using the Seed Vigor Imaging System (SVIS®). It has been concluded that the computerized analyses of seedling through growth indexes and vigor, using the SVIS®, is efficient to assess physiological potential of wheat seeds.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

NEWEST (Neoadjuvant Endocrine Therapy for Women with Estrogen-Sensitive Tumors) is the first study to compare biological and clinical activity of fulvestrant 500 versus 250 mg in the neoadjuvant breast cancer setting. We hypothesized that fulvestrant 500 mg may be superior to 250 mg in blocking estrogen receptor (ER) signaling and growth. A multicenter, randomized, open-label, Phase II study was performed to compare fulvestrant 500 mg (500 mg/month plus 500 mg on day 14 of month 1) versus fulvestrant 250 mg/month for 16 weeks prior to surgery in postmenopausal women with ER+ locally advanced breast cancer. Core biopsies at baseline, week 4, and surgery were assessed for biomarker changes. Primary endpoint: change in Ki67 labeling index (LI) from baseline to week 4 determined by automated computer imaging system (ACIS). Secondary endpoints: ER protein expression and function; progesterone receptor (PgR) expression; tumor response; tolerability. ER and PgR were examined retrospectively using the H score method. A total of 211 patients were randomized (fulvestrant 500 mg: n = 109; 250 mg: n = 102). At week 4, fulvestrant 500 mg resulted in greater reduction of Ki67 LI and ER expression versus 250 mg (-78.8 vs. -47.4% [p < 0.0001] and -25.0 vs. -13.5% [p = 0.0002], respectively [ACIS]); PgR suppression was not significantly different (-22.7 vs. -17.6; p = 0.5677). However, H score detected even greater suppression of ER (-50.3 vs. -13.7%; p < 0.0001) and greater PgR suppression (-80.5 vs. -46.3%; p = 0.0018) for fulvestrant 500 versus 250 mg. At week 16, tumor response rates were 22.9 and 20.6% for fulvestrant 500 and 250 mg, respectively, with considerable decline in all markers by both ACIS and H score. No detrimental effects on endometrial thickness or bone markers and no new safety concerns were identified. This provides the first evidence of greater biological activity for fulvestrant 500 versus 250 mg in depleting ER expression, function, and growth.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho foi conduzido com o objetivo de verificar a eficiência do sistema computadorizado de avaliação do vigor de sementes (SVIS®), em comparação com outros procedimentos disponíveis, em sementes de milho superdoce. Foram utilizadas sementes dos híbridos SWB 551 e SWB 585, cada uma representada por cinco lotes, conduzindo-se testes de germinação, envelhecimento acelerado (tradicional e com solução saturada de NaCl) e emergência de plântulas em campo. Para a determinação do vigor das sementes por meio do SVIS®, as plântulas foram avaliadas aos três dias após a semeadura do teste de germinação, sendo obtidos dados referentes ao índice de vigor, à uniformidade de desenvolvimento e ao comprimento de plântulas. Para ambos os híbridos avaliados, os resultados fornecidos pelo SVIS® foram coerentes com os do teste de envelhecimento acelerado tradicional. Concluiu-se que o SVIS® é eficiente para avaliação do vigor de sementes de milho superdoce, constituindo alternativa viável para a determinação do potencial fisiológico.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To report the audiological outcomes of cochlear implantation in two patients with severe to profound sensorineural hearing loss secondary to superficial siderosis of the CNS and discuss some programming peculiarities that were found in these cases. Retrospective review. Data concerning clinical presentation, diagnosis and audiological assessment pre- and post-implantation were collected of two patients with superficial siderosis of the CNS. Both patients showed good hearing thresholds but variable speech perception outcomes. One patient did not achieve open-set speech recognition, but the other achieved 70% speech recognition in quiet. Electrical compound action potentials could not be elicited in either patient. Map parameters showed the need for increased charge. Electrode impedances showed high longitudinal variability. The implants were fairly beneficial in restoring hearing and improving communication abilities although many reprogramming sessions have been required. The hurdle in programming was the need of frequent adjustments due to the physiologic variations in electrical discharges and neural conduction, besides the changes in the impedances. Patients diagnosed with superficial siderosis may achieve limited results in speech perception scores due to both cochlear and retrocochlear reasons. Careful counseling about the results must be given to the patients and their families before the cochlear implantation indication.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Several presentations of neurologic complications caused by JC virus (JCV) in human immunodeficiency virus (HIV)-infected patients have been described and need to be distinguished from the "classic" form of progressive multifocal leukoencephalopathy (PML). The objectives of this study were: 1) to describe the spectrum and frequency of presentations of JCV-associated central nervous system (CNS) diseases; 2) identify factors associated with in-hospital mortality of patients with JCV-associated CNS disease; and 3) to estimate the overall mortality of this population. Material and methods: This was a retrospective study of HIV-infected patients admitted consecutively for JCV-associated CNS diseases in a referral teaching center in Sao Paulo, Brazil, from 2002 to 2007. All patients with laboratory confirmed JCV-associated CNS diseases were included using the following criteria: compatible clinical and radiological features associated with the presence of JCV DNA in the cerebrospinal fluid. JCV-associated CNS diseases were classified as follows: 1) classic PML; 2) inflammatory PML; and 3) JC virus granule cell neuronopathy (GCN). Results: We included 47 cases. JCV-associated CNS diseases were classified as follows: 1) classic PML: 42 (89%); 2) inflammatory PML: three (6%); and 3) JC virus GCN: four (9%). Nosocomial pneumonia (p = 0.003), previous diagnosis of HIV infection (p = 0.03), and imaging showing cerebellar and/or brainstem involvement (p = 0.02) were associated with in-hospital mortality. Overall mortality during hospitalization was 34%. Conclusions: Novel presentations of JCV-associated CNS diseases were observed in our setting; nosocomial pneumonia, previous diagnosis of HIV infection, and cerebellar and/or brainstem involvement were associated with in-hospital mortality; and overall mortality was high. (C) 2012 Elsevier Editora Ltda. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

XML similarity evaluation has become a central issue in the database and information communities, its applications ranging over document clustering, version control, data integration and ranked retrieval. Various algorithms for comparing hierarchically structured data, XML documents in particular, have been proposed in the literature. Most of them make use of techniques for finding the edit distance between tree structures, XML documents being commonly modeled as Ordered Labeled Trees. Yet, a thorough investigation of current approaches led us to identify several similarity aspects, i.e., sub-tree related structural and semantic similarities, which are not sufficiently addressed while comparing XML documents. In this paper, we provide an integrated and fine-grained comparison framework to deal with both structural and semantic similarities in XML documents (detecting the occurrences and repetitions of structurally and semantically similar sub-trees), and to allow the end-user to adjust the comparison process according to her requirements. Our framework consists of four main modules for (i) discovering the structural commonalities between sub-trees, (ii) identifying sub-tree semantic resemblances, (iii) computing tree-based edit operations costs, and (iv) computing tree edit distance. Experimental results demonstrate higher comparison accuracy with respect to alternative methods, while timing experiments reflect the impact of semantic similarity on overall system performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Through-wall imaging (TWI) may provide vital information on interior environment in cases when physically entering such environment would pose danger to the person involved. The concept of ultra wideband radar (UWB radar) is an emerging technology, which offers high spatial resolution, as opposed to narrow band radars. Thus, TWI applications using UWB radar have become a growing field of research with several applications in the civil and defense areas such as rescue and surveillance. For this study, a prototype system of UWB radar to TWI has been built. Analyses and result to several kinds of experiments have been presented, that is, detection and visualization of metallic targets behind wooden board wall and concrete blocks wall. The results are encouraging and show the advantages of using UWB radar for TWI. (C) 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett, 54:339-344, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26543

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Perimedullary arteriovenous fistulas (PMAVFs) are rare spinal lesions and even more uncommon in children. Objective The aim of this study was to document rare occurrences of this type of arteriovenous malformation in six children treated at our institution. Methods The clinical data, radiological findings, and treatment in six cases of PMAVFs were reviewed. Six patients with PMAVFs were managed at our institution over a 5-year period. The patients (four girls and two boys), ranging in age from 6 to 15 years, presented with initially fluctuating, and eventually permanent and progressive, sudden-onset paraparesis, sensory disturbances, and sphincter dysfunction. The duration of symptoms before diagnosis ranged from 1 week to 13 years. Results All the patients underwent magnetic resonance imaging and spinal selective angiography, which demonstrated the characteristic imaging of an arteriovenous fistula. Embolization of the arteriovenous fistula was initially attempted in three patients with successful occlusion of the fistula in two. For the remaining cases, open surgery was performed, with complete occlusion of the fistula. There was no morbidity, regardless of the treatment performed. All the patients experienced neurological improvement after treatment. Conclusions No specific clinical or radiological characteristic of PMAVFs in the pediatric population was observed when our series was compared with a general series. Early diagnosis and timing of the therapeutic intervention seemed to avoid the development of irreversible ischemic myeloradiculopathy and prevented hemorrhage. Treatment for PMAVFs is difficult to standardize because these are extremely rare lesions with different angioarchitecture configurations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate if the Breast Imaging Reporting and Data System (BI-RADS) ultrasound descriptor of orientation can be used in magnetic resonance imaging (MRI). Materials and Methods: We conducted a retrospective study to evaluate breast mass lesions identified by MRI from 2008 to 2010 who had ultrasound (US) and histopathologic confirmation. Lesions were measured in the craniocaudal (CC), anteroposterior (AP), and transverse (T) axes and classified as having a nonparallel orientation, longest axis perpendicular to Cooper's ligaments, or in a parallel orientation when the longest axis is parallel to Cooper's ligaments. The MR image data were correlated with the US orientation according to BI-RADS and histopathological diagnosis. Results: We evaluated 71 lesions in 64 patients. On MRI, 27 lesions (38.0%) were nonparallel (8 benign and 19 malignant), and 44 lesions (62.0%) were parallel (33 benign and 11 malignant). There was significant agreement between the lesion orientation on US and MRI (kappa value = 0.901). The positive predictive values (PPV) for parallel orientation malignancy on MR and US imaging were 70.4% and 73.1%, respectively. Conclusion: A descriptor of orientation for breast lesions can be used on MRI with PPV for malignant lesions similar to US. J. Magn. Reson. Imaging 2012; 36:13831388. (C) 2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To propose an automatic brain tumor segmentation system. METHODS: The system used texture characteristics as its main source of information for segmentation. RESULTS: The mean correct match was 94% of correspondence between the segmented areas and ground truth. CONCLUSION: Final results showed that the proposed system was able to find and delimit tumor areas without requiring any user interaction.