27 resultados para Diagnostic Reasoning
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
Nowadays, the zinc oxide surge arresters (ZnO) are widely used in power systems, however, a large number of silicon carbide surge arresters (SiC) are still in service in the utilities. On the other hand, it is not possible to replace all SiC surge arresters in a short time period, being necessary to review the maintenance program taking into account the surge arresters that are more degraded. In this context, a research project was established between the University of Sao Paulo and the electrical utility CTEEP, aiming the investigation of its SiC surge arresters. This work shows that the leakage current measurement, a diagnostic method for the ZnO surge arresters, can provide useful information related to the condition of the SiC surge arresters. Analysis of the amplitude and distortion of the leakage current, also considering thermovision measurements, resulted in better evaluation of the SiC surge arresters.
Resumo:
PURPOSE: To evalulate the applicability of the Revised Diagnostic Criteria for Vogt-Koyanagi-Harada (VKH) disease to Brazilian patients and to verify the association between different disease categories, clinical parameters, and the presence of HLA-DRB1*0405. DESIGN: A retrospective observational case series. METHODS: Medical charts of 67 patients (10 to 64 years in age; 12 men and 55 women), from the Uveitis Service, Hospital das Clinicas, University of Sao Paulo School of Medicine (HCFMUSP), Sao Paulo, Brazil were reviewed. Patients, previously diagnosed with VKH disease using criteria proposed by the American Uveitis Society, underwent retrospective classification based on the Revised Diagnostic Criteria. The degree of concordance was assessed. At presentation, 46 patients (69%) were in the early phase. In this group, the mean time from disease onset to treatment was 15 days (range, one to 30 days). Forty-eight patients (72%) were typed for HLA-DRB1*0405 by polymerase chain reaction-sequence specific primer and polymerase chain reaction,sequence, specific oligonucleotides primer. Disease categories, phase at initial presentation, and ocular complications were analyzed. RESULTS: There was a 100% of concordance between the two criteria. Disease was classified as complete in 10 patients (15%), incomplete in 37 patients (55%), and probable in 20 patients (30%). In each group, respectively, 90%, 76%, and 45% were in the early phase at presentation (P = .017). There was no association between disease categories, the presence of HLA-DRB1*0405, and clinical parameters. CONCLUSION. The Revised Diagnostic Criteria proved useful for diagnosis of VKH disease in Brazilian patients. The present retrospective study did not find any association between disease category and severity parameters. To better understand the relevance of disease categories, a minimum follow-up period to categorize patients should be included in future prospective studies. (Am J Ophthalmol 2009;147:339-345. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Across the Americas and the Caribbean, nearly 561,000 slide-confirmed malaria infections were reported officially in 2008. The nine Amazonian countries accounted for 89% of these infections; Brazil and Peru alone contributed 56% and 7% of them, respectively. Local populations of the relatively neglected parasite Plasmodium vivax, which currently accounts for 77% of the regional malaria burden, are extremely diverse genetically and geographically structured. At a time when malaria elimination is placed on the public health agenda of several endemic countries, it remains unclear why malaria proved so difficult to control in areas of relatively low levels of transmission such as the Amazon Basin. We hypothesize that asymptomatic parasite carriage and massive environmental changes that affect vector abundance and behavior are major contributors to malaria transmission in epidemiologically diverse areas across the Amazon Basin. Here we review available data supporting this hypothesis and discuss their implications for current and future malaria intervention policies in the region. Given that locally generated scientific evidence is urgently required to support malaria control interventions in Amazonia, we briefly describe the aims of our current field-oriented malaria research in rural villages and gold-mining enclaves in Peru and a recently opened agricultural settlement in Brazil. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Activin A is a growth factor, produced by the endometrium, whose actions are modulated by the binding protein follistatin. Both proteins are detectable in the peripheral serum and their concentrations may be increased in women with endometriosis. The present study was designed to evaluate whether serum levels of activin A and follistatin are altered, and therefore have a potential diagnostic value, in women with peritoneal, ovarian and deep infiltrating endometriosis. We performed a multicenter controlled study evaluating simultaneously serum activin A and follistatin concentrations in women with and without endometriosis. Women with endometriosis (n 139) were subdivided into three groups: peritoneal endometriosis (n 28); ovarian endometrioma (n 61) and deep infiltrating endometriosis (n 50). The control group (n 75) consisted of healthy women with regular menstrual cycles. Blood samples were collected from a peripheral vein and assayed for activin A and follistatin using commercially available enzyme immunoassay kits. The ovarian endometrioma group had serum activin A levels significantly higher than healthy controls (0.22 0.01 ng/ml versus 0.17 0.01 ng/ml, P 0.01). None of the endometriosis groups had serum follistatin levels which were significantly altered compared with healthy controls; however, levels found in the endometrioma group (2.34 0.32 ng/ml) were higher than that in the deep endometriosis group (1.50 0.17 ng/ml, P 0.05). The area under the receiver operating characteristic curve of activin A was 0.700 (95 confidence interval: 0.6050.794), while that of follistatin was 0.620 (95 confidence interval: 0.5100.730) for the diagnosis of ovarian endometrioma. The combination of both markers into a duo marker index did not improve significantly their diagnostic accuracy. The present study demonstrated that serum activin A and follistatin are not significantly altered in peritoneal or deep infiltrating endometriosis and have limited diagnostic accuracy in the diagnosis of ovarian endometrioma.
Resumo:
This article describes the development and evaluation of software that verifies the accuracy of diagnoses made by nursing students. The software was based on a model that uses fuzzy logic concepts, including PERL, the MySQL database for Internet accessibility, and the NANDA-I 2007-2008 classification system. The software was evaluated in terms of its technical quality and usability through specific instruments. The activity proposed in the software involves four stages in which students establish the relationship values between nursing diagnoses, defining characteristics/risk factors and clinical cases. The relationship values determined by students are compared to those of specialists, generating performance scores for the students. In the evaluation, the software demonstrated satisfactory outcomes regarding the technical quality and, according to the students, helped in their learning and may become an educational tool to teach the process of nursing diagnosis.
Resumo:
Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4748519]
Resumo:
Objective: To compare two methods of respiratory inductive plethysmography (RIP) calibration in three different positions. Methods: We evaluated 28 healthy subjects (18 women and 10 men), with a mean age of 25.4 +/- 3.9 years. For all of the subjects, isovolume maneuver calibration (ISOCAL) and qualitative diagnostic calibration (QDC) were used in the orthostatic, sitting, and supine positions. In order to evaluate the concordance between the two calibration methods, we used ANOVA and Bland-Altman plots. Results: The values of the constant of proportionality (X) were significantly different between ISOCAL and QDC in the three positions evaluated: 1.6 +/- 0.5 vs. 2.0 +/- 1.2, in the supine position, 2.5 +/- 0.8 vs. 0.6 +/- 0.3 in the sitting position, and 2.0 +/- 0.8 vs. 0.6 +/- 0.3 in the orthostatic position (p < 0.05 for all). Conclusions: Our results suggest that QDC is an inaccurate method for the calibration of RIP. The K values obtained with ISOCAL reveal that RIP should be calibrated for each position evaluated.
Resumo:
Neurosonological studies, specifically transcranial Doppler (TCD) and transcranial color-coded duplex (TCCD), have high level of specificity and sensitivity and they are used as complementary tests for the diagnosis of brain death (BD). A group of experts, from the Neurosonology Department of the Brazilian Academy of Neurology, created a task force to determine the criteria for the following aspects of diagnosing BD in Brazil: the reliability of TCD methodology; the reliability of TCCD methodology; neurosonology training and skills; the diagnosis of encephalic circulatory arrest; and exam documentation for BD. The results of this meeting are presented in the current paper.
Resumo:
We propose a new general Bayesian latent class model for evaluation of the performance of multiple diagnostic tests in situations in which no gold standard test exists based on a computationally intensive approach. The modeling represents an interesting and suitable alternative to models with complex structures that involve the general case of several conditionally independent diagnostic tests, covariates, and strata with different disease prevalences. The technique of stratifying the population according to different disease prevalence rates does not add further marked complexity to the modeling, but it makes the model more flexible and interpretable. To illustrate the general model proposed, we evaluate the performance of six diagnostic screening tests for Chagas disease considering some epidemiological variables. Serology at the time of donation (negative, positive, inconclusive) was considered as a factor of stratification in the model. The general model with stratification of the population performed better in comparison with its concurrents without stratification. The group formed by the testing laboratory Biomanguinhos FIOCRUZ-kit (c-ELISA and rec-ELISA) is the best option in the confirmation process by presenting false-negative rate of 0.0002% from the serial scheme. We are 100% sure that the donor is healthy when these two tests have negative results and he is chagasic when they have positive results.
Resumo:
Holsback L., Pena H.F.J., Ragozo A., Lopes E. G., Gennari S. M. & Soares R. M. 2012. Serologic and molecular diagnostic and bioassay in mice for detection of Toxoplasma gondii in free range chickens from Pantanal of Mato Grosso do Sul. Pesquisa Veterinaria Brasileira 32(8): 721-726. Setor de Veterinaria e Producao Animal, Universidade Estadual do Norte do Parana, Campus Luiz Meneghel, Rodovia BR 369 Km 54, Bandeirantes, PR 86360-000, Brazil. E-mail: lhsfertonani@uenp.edu.br The aim of this study was to investigate the occurrence of Toxoplasma gondii and compare the results obtained in the Modified Agglutination Test (MAT), Polimerase Chain Reaction (PCR) and bioassay in mice. In order to accomplish this, 40 free-range chickens from eight farms in neighboring areas to the Pantanal in Nhecolandia, Mato Grosso do Sul, were euthanized and blood samples, brain and heart were collected. The occurrence of anti-T. gondii antibodies found in chickens was 67.5% (27 samples), considering as a cutoff point the dilution 1:5. Among the samples analyzed, 7 (25.9%) were positive in the dilution 1: 5, 3 (11.1%) in 1: 10, 2 (7.4%) in 1: 20, 3 (11.1%) in 1: 320, 1 (3.7%) in 1: 640, 3 (11.1%) in 1: 1280, 2 (7.4%) in 1: 2560, 4 (14.8%) in 1: 5120 and 2 (7.4%) in 1: 10.240. From the mixture of tissue samples (brain and heart) from the chickens analyzed, 16 (40%) presented electrophoretic bands compatible with T. gondii by PCR (gene B1). In the comparison of techniques, 59.26% positivity in PCR was revealed among animals that were seropositive in MAT (cutoff 1: 5). From 141 inoculated mice, six (4.44%) died of acute toxoplasmosis between 15 and 23 days after inoculation. Surviving mice were sacrificed at 74 days after inoculation, and a total of 28 cysts were found in the brains of 10 distinct groups. From the seropositive hens, 27 bioassays were performed and 11 (40.7%) isolates were obtained. A greater number of isolations happened in mice that were inoculated with tissues from chickens that had high titers for anti-T. gondii antibodies. Chronic infection in mice was observed in nine groups (33.3%) from five different properties. Among the surviving mice, 25.6% were positive for T. gondii in MAT (1: 25). From mice positive in PCR, 87.5% were also positive in MAT. Among the PCR-negative mice, 5.2% were positive for T. gondii in MAT. It can be concluded through this study that the occurrence of infecton by T. gondii in the rural properties studied was high, that PCR directed to gene B1 does not confirm the viability of the parasite, but it can be used as a screening method for the selection of chickens infected by T. gondii, that the animals with titer greater than 10 must be prioritized for the selection of animals for bioassay, since for them, the chances of isolating the parasite are greater and that seroconversion in experimentally infected mice is not a good indicator for isolating the agent.
Resumo:
Many findings from research as well as reports from teachers describe students' problem solving strategies as manipulation of formulas by rote. The resulting dissatisfaction with quantitative physical textbook problems seems to influence the attitude towards the role of mathematics in physics education in general. Mathematics is often seen as a tool for calculation which hinders a conceptual understanding of physical principles. However, the role of mathematics cannot be reduced to this technical aspect. Hence, instead of putting mathematics away we delve into the nature of physical science to reveal the strong conceptual relationship between mathematics and physics. Moreover, we suggest that, for both prospective teaching and further research, a focus on deeply exploring such interdependency can significantly improve the understanding of physics. To provide a suitable basis, we develop a new model which can be used for analysing different levels of mathematical reasoning within physics. It is also a guideline for shifting the attention from technical to structural mathematical skills while teaching physics. We demonstrate its applicability for analysing physical-mathematical reasoning processes with an example.
Resumo:
Auriculo-condylar syndrome (ACS) is characterized by typical ears malformation (so-called "question mark" ears), prominent cheeks, microstomia, and abnormality of the temporomandibular joint and condyle of the mandible. In this report we describe a new simplex case and a previously unreported family with affected individuals in three generations documenting clinical variability. Linkage study for markers located in candidate region for ACS1 (1p21.1-q23.3) was excluded in our familial case, reinforcing the hypothesis of genetic heterogeneity for this condition. A review of the literature focusing diagnostic criteria and features of ACS was performed. (C) 2011 Wiley Periodicals, Inc.
Resumo:
PURPOSE: Apply the educational software Fuzzy Kitten with undergraduate Brazilian nursing students. METHODS: This software, based on fuzzy logic, generates performance scores that evaluate the ability to identify defining characteristics/risk factors present in clinical cases, relate them with nursing diagnoses, and determine the diagnoses freely or using a decision support model. FINDINGS: There were differences in student performance compared to the year of the course. The time to perform the activity did not present a significant relation to the performance. The students' scores in the diagnoses indicated by the model was superior (p = .01). CONCLUSIONS: The software was able to evaluate the diagnostic accuracy of students. IMPLICATIONS: The software enables an objective evaluation of diagnostic accuracy.
Resumo:
PURPOSE: Acute pain occurs in over 50% of hospitalized children. The accuracy of this diagnosis has been underexplored in the literature, as has the role of training to implement pain assessment. This study analyzed the accuracy of acute pain diagnoses after the implementation of a systematic evaluation of pain (study intervention). METHOD: The sample was divided into: pre- and postintervention. The Nursing Diagnosis Accuracy Scale, which scores accuracy as null, low, moderate, or high, was used. RESULTS: In the postimplementation, acute pain was diagnosed more often. However, accuracy only improved in the moderate category. CONCLUSION: Diagnosis of acute pain increased in the postimplementation period, but accuracy did not. IMPLICATIONS: The development of strategies for improvement of diagnostic accuracy is warranted.
Resumo:
Objective: Sepsis is a common condition encountered in hospital environments. There is no effective treatment for sepsis, and it remains an important cause of death at intensive care units. This study aimed to discuss some methods that are available in clinics, and tests that have been recently developed for the diagnosis of sepsis. Methods: A systematic review was performed through the analysis of the following descriptors: sepsis, diagnostic methods, biological markers, and cytokines. Results: The deleterious effects of sepsis are caused by an imbalance between the invasiveness of the pathogen and the ability of the host to mount an effective immune response. Consequently, the host's immune surveillance fails to eliminate the pathogen, allowing it to spread. Moreover, there is a pro-inflammatory mediator release, inappropriate activation of the coagulation and complement cascades, leading to dysfunction of multiple organs and systems. The difficulty achieve total recovery of the patient is explainable. There is an increased incidence of sepsis worldwide due to factors such as aging population, larger number of surgeries, and number of microorganisms resistant to existing antibiotics. Conclusion: The search for new diagnostic markers associated with increased risk of sepsis development and molecules that can be correlated to certain steps of sepsis is becoming necessary. This would allow for earlier diagnosis, facilitate patient prognosis characterization, and prediction of possible evolution of each case. All other markers are regrettably constrained to research units.