3 resultados para DISCHARGE CHARACTERISTICS

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Leao RM, Li S, Doiron B, Tzounopoulos T. Diverse levels of an inwardly rectifying potassium conductance generate heterogeneous neuronal behavior in a population of dorsal cochlear nucleus pyramidal neurons. J Neurophysiol 107: 3008-3019, 2012. First published February 29, 2012; doi:10.1152/jn.00660.2011.-Homeostatic mechanisms maintain homogeneous neuronal behavior among neurons that exhibit substantial variability in the expression levels of their ionic conductances. In contrast, the mechanisms, which generate heterogeneous neuronal behavior across a neuronal population, remain poorly understood. We addressed this problem in the dorsal cochlear nucleus, where principal neurons exist in two qualitatively distinct states: spontaneously active or not spontaneously active. Our studies reveal that distinct activity states are generated by the differential levels of a Ba2+-sensitive, inwardly rectifying potassium conductance (K-ir). Variability in K-ir maximal conductance causes variations in the resting membrane potential (RMP). Low K-ir conductance depolarizes RMP to voltages above the threshold for activating subthreshold-persistent sodium channels (Na-p). Once Na-p channels are activated, the RMP becomes unstable, and spontaneous firing is triggered. Our results provide a biophysical mechanism for generating neural heterogeneity, which may play a role in the encoding of sensory information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To ascertain incidence and predictors of new permanent pacemaker (PPM) following transcatheter aortic valve implantation (TAVI) with the self-expanding aortic bioprosthesis. Background: TAVI with the Medtronic Corevalve (MCV) Revalving System (Medtronic, Minneapolis, MN) has been associated with important post-procedural conduction abnormalities and frequent need for PPM. Methods: Overall, 73 consecutive patients with severe symptomatic AS underwent TAVI with the MCV at two institutions; 10 patients with previous pacemaker and 3 patients with previous aortic valve replacement were excluded for this analysis. Clinical, echocardiographic, and procedural data were collected prospectively in a dedicated database. A standard 12-lead ECG was recorded in all patients at baseline, after the procedure and predischarge. Decision to implant PPM was taken according to current guidelines. Logistic multivariable modeling was applied to identify independent predictors of PPM at discharge. Results: Patients exhibited high-risk features as evidenced by advanced age (mean = 82.1 +/- 6.2 years) and high surgical scores (logistic EuroSCORE 23.0 +/- 12.8%, STS score 9.4 +/- 6.9%). The incidence of new PPM was 28.3%. Interventricular septum thickness and logistic Euroscore were the baseline independent predictors of PPM. When procedural variables were included, the independent predictors of PPM were interventricular septum thickness (OR 0.52; 95% CI 0.320.85) and the distance between noncoronary cusp and the distal edge of the prosthesis (OR 1.37; 95% CI 1.031.83). Conclusions: Conduction abnormalities are frequently observed after TAVI with self-expandable bioprosthesis and definitive pacing is required in about a third of the patients, with a clear association with depth of implant and small interventricular septum thickness. (c) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Atrial fibrillation is a serious public health problem posing a considerable burden to not only patients, but the healthcare environment due to high rates of morbidity, mortality, and medical resource utilization. There are limited data on the variation in treatment practice patterns across different countries, healthcare settings and the associated health outcomes. Methods/design: RHYTHM-AF was a prospective observational multinational study of management of recent onset atrial fibrillation patients considered for cardioversion designed to collect data on international treatment patterns and short term outcomes related to cardioversion. We present data collected in 10 countries between May 2010 and June 2011. Enrollment was ongoing in Italy and Brazil at the time of data analysis. Data were collected at the time of atrial fibrillation episode in all countries (Australia, Brazil, France, Germany, Italy, Netherlands, Poland, Spain, Sweden, United Kingdom), and cumulative follow-up data were collected at day 60 (+/- 10) in all but Spain. Information on center characteristics, enrollment data, patient demographics, detail of atrial fibrillation episode, medical history, diagnostic procedures, acute treatment of atrial fibrillation, discharge information and the follow-up data on major events and rehospitalizations up to day 60 were collected. Discussion: A total of 3940 patients were enrolled from 175 acute care centers. 70.5% of the centers were either academic (44%) or teaching (26%) hospitals with an overall median capacity of 510 beds. The sites were mostly specialized with anticoagulation clinics (65.9%), heart failure (75.1%) and hypertension clinics (60.1%) available. The RHYTHM-AF registry will provide insight into regional variability of antiarrhythmic and antithrombotic treatment of atrial fibrillation, the appropriateness of such treatments with respect to outcomes, and their cost-efficacy. Observations will help inform strategies to improve cardiovascular outcomes in patients with atrial fibrillation.