7 resultados para DIAGNOdent 2095

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid in vitro methods for measuring digestibility may be useful in analysing aqua feeds if the extent and limits of their application are clearly defined. The pH-stat protein digestibility routine with shrimp hepatopancreas enzymes was previously related to apparent protein digestibility with juvenile Litopenaeus vannamei fed diets containing different protein ingredients. The potential of the method to predict culture performance of shrimp fed six commercial feeds (T3, T4, T5, T6, T7 and T8) with 350 g kg(-1) declared crude-protein content was assessed. The consistency of results obtained using hepatopancreas enzyme extracts from either pond or clear water-raised shrimp was further verified in terms of reproducibility and possible diet history effects upon in vitro outputs. Shrimps were previously acclimated and then maintained over 56 days (initial mean weight 3.28 g) on each diet in 500-L tanks at 114 ind m(-2), clear water closed system with continuous renewal and mechanical filtering (50 mu m), with four replicates per treatment. Feeds were offered four times daily (six days a week) delivered in trays at feeding rates ranging from 4.0% to 7.0% of stocked shrimp biomass. Feed was accessible to shrimp 4 h daily for 1-h feeding period after which uneaten feed was recovered. Growth and survival were determined every 14 days from a sample of 16 individuals per tank. Water quality was monitored daily (pH, temperature and salinity) and managed by water back flushing filter cleaning every 7-10 days. Feeds were analysed for crude protein, gross energy, amino acids and pepsin digestibility. In vitro pH-stat degree of protein hydrolysis (DH%) was determined for each feed using hepatopancreas enzyme extracts from experimental (clear water) or pond-raised shrimp. Feeds resulted in significant differences in shrimp performance (P < 0.05) as seen by the differences in growth rates (0.56-0.98 g week(-1)), final weight and feed conversion ratio (FCR). Shrimp performance and in vitro DH% with pond-raised shrimp enzymes showed significant correlation (P < 0.05) for yield (R-2 = 0.72), growth rates (R-2 = 0.72-0.80) and FCR (R-2 = -0.67). Other feed attributes (protein : energy ratio, amino acids, true protein, non-protein nitrogen contents and in vitro pepsin digestibility) showed none or limited correlation with shrimp culture performance. Additional correlations were found between growth rates and methionine (R-2 = 0.73), FCR and histidine (R-2 = -0.60), and DH% and methionine or methionine+cystine feed contents (R-2 = 0.67-0.92). pH-stat assays with shrimp enzymes generated reproducible DH% results with either pond (CV <= 6.5%) or clear water (CV <= 8.5%) hepatopancreas enzyme sources. Moreover, correlations between shrimp growth rates and feed DH% were significant regardless of the enzyme origin (pond or clear water-raised shrimp) and showed consistent R-2 values. Results suggest the feasibility of using standardized hepatopancreas enzyme extracts for in vitro protein digestibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate the influence of interdental spacing on the performance of proximal caries detection methods in primary molars. In addition, aspects related to temporary tooth separation with orthodontic separators were evaluated. The proximal spaces between the posterior primary teeth (n = 344) of 76 children (4-12 years old) were evaluated before and after temporary separation. Stainless steel strips with different standardized thicknesses were used to measure the presence of biological spacing and the spacing obtained after temporary separation with orthodontic rubber rings. First, the presence of proximal caries lesions was assessed by visual inspection, bitewing radiographs and a pen-type laser fluorescence device (DIAGNOdent pen). Visual inspection after temporary separation with separators was the reference standard method in checking the actual presence of caries. Multilevel analyses were performed considering different outcomes: the performance of the methods in detecting caries lesions and the spacing after temporary separation. The spacing did not influence the performance of the caries detection methods. The maximum spacing obtained with temporary tooth separation was 0.80 mm (mean +/- standard deviation = 0.46 +/- 0.13 mm). The temporary separation was more effective in the upper arch and less effective when an initial biological interdental spacing was present. The biological interdental spacing does not influence the performance of proximal caries detection methods in primary molars, and temporary tooth separation provides spacing narrower than 1.0 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine the influence of thickness and aging on the intrinsic fluorescence of sealing materials and their ability to block fluorescence from the underlying surface as assessed using a laser fluorescence device. Cavities of 0.5 mm and 1 mm depth were drilled into acrylic boards which were placed over two surfaces with different fluorescence properties: a low-fluorescence surface, to assess the intrinsic fluorescence of the sealing materials, and a high-fluorescence surface, to assess the fluorescence-blocking ability of the sealing materials. Ten cavities of each depth were filled with different sealing materials: Adper Scotchbond Multi-Purpose, Adper Single Bond 2, FluroShield, Conseal f and UltraSeal XT Plus. Fluorescence was measured with a DIAGNOdent pen at five different time points: empty cavity, after polymerization, and 1 day, 1 week and 1 month after filling. The individual values after polymerization, as well as the area under the curve for the different periods were submitted to ANOVA and the Tukey test (p < 0.05). At 0.5 mm, Scotchbond, FluroShield and UltraSeal showed insignificant changes in intrinsic fluorescence with aging and lower fluorescence after polymerization than Single Bond and Conseal. At 1 mm, Scotchbond and FluroShield showed the lowest intrinsic fluorescence, but only Scotchbond showed no chagnes in fluorescence with aging. At both depths, Scotchbond blocked significantly less fluorescence. All sealing materials blocked more fluorescence when applied to a depth of 1 mm. At 0.5 mm, fissure sealants blocked more fluorescence than adhesives, and did not show significant changes with aging. Scotchbond had the least affect on the fluorescence from the underlying surface and would probably have the least affect on the monitoring of sealed dental caries by laser fluorescence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Known as the "king of spices", black pepper (Piper nigrum), a perennial crop of the tropics, is economically the most important and the most widely used spice crop in the world. To understand its suitable bioclimatic distribution, maximum entropy based on ecological niche modeling was used to model the bioclimatic niches of the species in its Asian range. Based on known occurrences, bioclimatic areas with higher probabilities are mainly located in the eastern and western coasts of the Indian Peninsula, the east of Sumatra Island, some areas in the Malay Archipelago, and the southeast coastal areas of China. Some undocumented places were also predicted as suitable areas. According to the jackknife procedure, the minimum temperature of the coldest month, the mean monthly temperature range, and the precipitation of the wettest month were identified as highly effective factors in the distribution of black pepper and could possibly account for the crop's distribution pattern. Such climatic requirements inhibited this species from dispersing and gaining a larger geographical range.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

International Journal of Paediatric Dentistry 2012; 22: 459466 Aim. This in vitro study aimed to test the performance of fluorescence-based methods in detecting occlusal caries lesions in primary molars compared to conventional methods. Design. Two examiners assessed 113 sites on 77 occlusal surfaces of primary molars using three fluorescence devices: DIAGNOdent (LF), DIAGNOdent pen (LFpen), and fluorescence camera (VistaProof-FC). Visual inspection (ICDAS) and radiographic methods were also evaluated. One examiner repeated the evaluations after one month. As reference standard method, the lesion depth was determined after sectioning and evaluation in stereomicroscope. The area under the ROC curve (Az), sensitivity, specificity, and accuracy of the methods were calculated at enamel (D1) and dentine caries (D3) lesions thresholds. The intra and interexaminer reproducibility were calculated using the intraclass correlation coefficient (ICC) and kappa statistics. Results. At D1, visual inspection presented higher sensitivities (0.970.99) but lower specificities (0.180.25). At D3, all the methods demonstrated similar performance (Az values around 0.90). Visual and radiographic methods showed a slightly higher specificity (values higher than 0.96) than the fluorescence based ones (values around 0.88). In general, all methods presented high reproducibility (ICC higher than 0.79). Conclusions. Although fluorescence-based and conventional methods present similar performance in detecting occlusal caries lesions in primary teeth, visual inspection alone seems to be sufficient to be used in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the influence of dental plaque and moisture on performance of a laser fluorescence device in detecting occlusal and proximal caries lesions in primary teeth. Fifty-five occlusal and 58 proximal sites on primary molars were evaluated using a DIAGNOdent pen (LFpen) device. For the drying time study, the evaluations were performed in: (I) moist teeth; (II) teeth dried for 3 s, or (III) dried for 15 s. For the plaque study, the evaluations were done in sites: (I) without plaque; (II) with plaque, and (III) after cleaning. Evaluation of the teeth sections in stereomicroscope was the reference standard method. LF pen values, sensitivity, specificity, and accuracy were compared. The values obtained after 15 s of drying were higher than those obtained with moist teeth or dried for 3 s at both occlusal and proximal surfaces. However, there was no change in the performance in detecting caries lesions. With regard to the presence of plaque, there was no significant change in the readings of the device, but specificity was decreased in occlusal surfaces with plaque. At proximal surfaces, however, no significant differences were observed. In conclusion, the moisture conditions do not influence significantly the performance of the LFpen, but the presence of plaque can affect its performance in detecting occlusal caries lesions in primary teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because discomfort caused by different approximal caries detection methods can influence their performance, the assessment of this discomfort is important. Thus, this study aimed to evaluate the discomfort reported by children after the use of different diagnostic methods to detect approximal caries lesions in primary teeth: visual inspection, bitewing radiography, laser fluorescence (DIAGNOdent pen - LFpen) and temporary separation with orthodontic rubbers. Seventy-six children aged 4 to 12 years were examined using these methods. Their discomfort was assessed using the Wong-Baker scale and compared among the methods. Visual inspection caused less discomfort than did other methods. Radiography and the LFpen presented similar levels of discomfort. Older children reported higher discomfort using temporary separation, whereas younger children reported less discomfort with the LFpen. In conclusion, radiographic, temporary separation and LFpen methods provoke higher discomfort than visual inspection.